EN ISO 10993-17:2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances (ISO 10993-17:2002)
21-03-2010
29-04-2009
Foreword
Introduction
1 Scope
2 Normative reference
3 Terms and definitions
4 General principles for establishing allowable limits
5 Establishment of tolerable intake (TI) for specific
leachable substances
5.1 General
5.2 Exposure considerations for TI calculation
5.3 Collection and evaluation of data
5.4 Set TI for noncancer endpoints
5.5 Set TI for cancer endpoints
5.6 Establishment of tolerable contact levels (TCLs)
5.7 Risk assessment of mixtures
6 Calculation of tolerable exposure (TE)
6.1 General
6.2 Exposure population
6.3 Calculation of utilization factor from intended
use pattern
6.4 Tolerable exposure
7 Feasibility evaluation
8 Benefit evaluation
9 Allowable limits
10 Reporting requirements
Annex A (informative) - Some typical assumptions for
biological parameters
Annex B (informative) - Risk assessment for mixtures
of leachable substances
Annex C (informative) - Conversion of allowable limits
for systemic exposure and for body surface
contact to maximum dose to patient from a
medical device
Annex D (informative) - Risk analysis report
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 93/42/EEC on Medical Devices
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 90/385/EEC on Active Implantable
Medical Devices
ISO 10993-17:2002 specifies the determination of allowable limits for substances leachable from medical devices. It is intended for use in deriving standards and estimating appropriate limits where standards do not exist. It describes a systematic process through which identified risks arising from toxicologically hazardous substances present in medical devices can be quantified. ISO 10993-17:2002 is not applicable to devices that have no patient contact (e.g. in vitro diagnostic devices). Exposure to a particular chemical substance may arise from sources other than the device, such as food, water or air. ISO 10993-17:2002 does not address the potential for exposure from such sources.
Committee |
CEN/TC 206
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DS EN ISO 10993-17 : 2009 | Identical |
DS/EN ISO 10993-17:2023 | Identical |
NBN EN ISO 10993-17 : 2009 | Identical |
UNI EN ISO 10993-17 : 2009 | Identical |
BS EN ISO 10993-17:2009 | Identical |
SN EN ISO 10993-17 : 2009 | Identical |
DIN EN ISO 10993-17:2009-08 | Identical |
NF EN ISO 10993-17 : 2009 | Identical |
ISO 10993-17:2002 | Identical |
I.S. EN ISO 10993-17:2009 | Identical |
NEN EN ISO 10993-17 : 2009 | Identical |
NS EN ISO 10993-17 : 2009 | Identical |
PN EN ISO 10993-17 : 2009 | Identical |
UNE-EN ISO 10993-17:2009 | Identical |
ONORM EN ISO 10993-17 : 2009 | Identical |
I.S. EN 15424:2007 | STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES |
15/30278540 DC : 0 | BS ISO 18562-4 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 4: TESTS FOR LEACHABLES IN CONDENSATE |
05/30066638 DC : DRAFT OCT 2005 | EN 15424 - STERILIZATION OF MEDICAL DEVICES - DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF STERILIZATION PROCESSES - LOW TEMPERATURE STEAM AND FORMALDEHYDE |
I.S. EN ISO 7198:2017 | CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - VASCULAR PROSTHESES - TUBULAR VASCULAR GRAFTS AND VASCULAR PATCHES (ISO 7198:2016) |
BS EN 15424:2007 | Sterilization of medical devices. Low temperature steam and formaldehyde. Requirements for development, validation and routine control of a sterilization process for medical devices |
DIN EN 15424:2007-08 | STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES |
ISO 25424:2009 | Sterilization of medical devices Low temperature steam and formaldehyde Requirements for development, validation and routine control of a sterilization process for medical devices |
UNI EN ISO 25424 : 2011 | STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES |
UNE-EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016) |
I.S. EN ISO 25424:2011 | STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES |
DIN EN ISO 25424:2011-09 | STERILIZATION OF MEDICAL DEVICES - LOW TEMPERATURE STEAM AND FORMALDEHYDE - REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES |
BS EN ISO 25539-1:2017 | Cardiovascular implants. Endovascular devices Endovascular prostheses |
PREN 17180 : DRAFT 2017 | STERILIZERS FOR MEDICAL PURPOSES - LOW TEMPERATURE VAPORIZED HYDROGEN PEROXIDE STERILIZERS - REQUIREMENTS AND TESTING |
04/30081258 DC : DRAFT MARCH 2004 | BS EN ISO 11737-1 - STERILIZATION OF MEDICAL DEVICES - MICROBIOLOGICAL METHODS - PART 1 - DETERMINATION OF A POPULATION OF MICRO ORGANISMS ON PRODUCTS |
15/30278530 DC : 0 | BS ISO 18562-1 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS |
15/30278537 DC : 0 | BS ISO 18562-3 - BIOCOMPATIBILITY EVALUATION OF BREATHING GAS PATHWAYS IN HEALTHCARE APPLICATIONS - PART 3: TESTS FOR EMISSIONS OF VOLATILE ORGANIC COMPOUNDS (VOCS) |
I.S. EN ISO 25539-1:2017 | CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017) |
EN 15424:2007 | Sterilization of medical devices - Low temperature steam and formaldehyde - Requirements for development, validation and routine control of a sterilization process for medical devices |
EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems - Vascular prostheses - Tubular vascular grafts and vascular patches (ISO 7198:2016) |
EN ISO 25424:2011 | Sterilization of medical devices - Low temperature steam and formaldehyde - Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 25424:2009) |
BS EN ISO 25424:2011 | Sterilization of medical devices. Low temperature steam and formaldehyde. Requirements for development, validation and routine control of a sterilization process for medical devices |
BS EN ISO 7198:2017 | Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches |
UNE-EN ISO 25424:2011 | Sterilization of medical devices - Low temperature steam and formaldehyde - Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 25424:2009) |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |