• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 846-14:2012

Current

Current

The latest, up-to-date edition.

Methods of test for ancillary components for masonry - Part 14: Determination of the initial shear strength between the prefabricated part of a composite lintel and the masonry above it

Published date

12-09-2012

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Principle
4 Terms, definitions and symbols
5 Materials
6 Apparatus
7 Preparation and curing of specimens
8 Procedure
9 Calculations
10 Evaluation of results
11 Test report
Annex A (informative) - Types of failure
Bibliography

This European Standard specifies a method for determining the in plane initial shear strength of thehorizontal bed joint between the prefabricated part of a composite lintel and the masonry above it,using a specimen tested in shear. Guidance is given on the preparation of the specimens, the conditioning required before testing, the testing machine, the method of test, the method of calculation and the contents of the test report. The method corresponds with the method described in EN 1052-3:2003+A1:2006. Guidance is given where the method deviates from EN 1052-3. Therefore, each section of EN 1052-3 is repeated given the necessary changes.

Committee
CEN/TC 125
DevelopmentNote
Supersedes PREN 846-14. (09/2012)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
NS EN 846-14 : 2012 Identical
NBN EN 846-14 : 2012 Identical
BS EN 846-14:2012 Identical
I.S. EN 846-14:2012 Identical
UNE-EN 846-14:2013 Identical
DIN EN 846-14:2012-11 Identical
PN EN 846-14 : 2012 Identical
SN EN 846-14 : 2012 Identical
NF EN 846-14 : 2013 Identical
NEN EN 846-14 : 2012 Identical
UNI EN 846-14 : 2012 Identical

PREN 845-1 : DRAFT 2012 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 1: WALL TIES, TENSION STRAPS, HANGERS AND BRACKETS
BS EN 845-2 : 2013 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS
12/30265756 DC : 0 BS EN 845-1 - SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 1: WALL TIES, TENSION STRAPS, HANGERS AND BRACKETS
I.S. EN 845-2:2013 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS
I.S. EN 845-1:2013 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 1: WALL TIES, TENSION STRAPS, HANGERS AND BRACKETS
PREN 845-2 : DRAFT 2012 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS
BS EN 845-1 : 2013 SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 1: WALL TIES, TENSION STRAPS, HANGERS AND BRACKETS
EN 845-2:2013+A1:2016 Specification for ancillary components for masonry - Part 2: Lintels
EN 845-1:2013+A1:2016 Specification for ancillary components for masonry - Part 1: Wall ties, tension straps, hangers and brackets
12/30265747 DC : 0 BS EN 845-2 - SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS

EN 998-2:2016 Specification for mortar for masonry - Part 2: Masonry mortar
EN 845-2:2013+A1:2016 Specification for ancillary components for masonry - Part 2: Lintels
EN 772-1:2011+A1:2015 Methods of test for masonry units - Part 1: Determination of compressive strength
EN 1015-7:1998 Methods of test for mortar for masonry - Part 7: Determination of air content of fresh mortar
EN 1015-11 : 1999 AMD 1 2006 METHODS OF TEST FOR MORTAR FOR MASONRY - PART 11: DETERMINATION OF FLEXURAL AND COMPRESSIVE STRENGTH OF HARDENED MORTAR
EN 772-16:2011 Methods of test for masonry units - Part 16: Determination of dimensions
EN 772-10:1999 Methods of test for masonry units - Part 10: Determination of moisture content of calcium silicate and autoclaved aerated concrete units

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.