EN 62619:2017
Current
The latest, up-to-date edition.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
19-05-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Parameter measurement tolerances
5 General safety considerations
6 Type test conditions
7 Specific requirements and tests
8 Battery system safety (considering functional safety)
9 Information for safety
10 Marking and designation
Annex A (normative) - Operating region of cells for safe use
Annex B (informative) - Procedure of propagation test
Annex C (informative) - Packaging
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 62619:2017 specifies requirements and tests for the safe operation of secondary lithium cells and batteries used in industrial applications including stationary applications.When there exists an IEC standard specifying test conditions and requirements for cells used in special applications and which is in conflict with this document, the former takes precedence (e.g., IEC62660 series on road vehicles).The following are some examples of applications that utilize cells and batteries under the scope of this document.- Stationary applications: telecom, uninterruptible power supplies (UPS), electrical energy storage system, utility switching, emergency power, and similar applications.- Motive applications: forklift truck, golf cart, auto guided vehicle (AGV), railway, and marine, excluding road vehicles.Since this document covers batteries for various industrial applications, it includes those requirements, which are common and minimum to the various applications.Electrical safety is included only as a part of the risk analysis of Clause 8. In regard to details for addressing electrical safety, the end use application standard requirements have to be considered.This document applies to cells and batteries. If the battery is divided into smaller units, the smaller unit can be tested as the representative of the battery. The manufacturer clearly declares the tested unit. The manufacturer may add functions, which are present in the final battery to the tested unit.
Committee |
CLC/TC 21X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI EN 62619 : 1ED 2017 | Identical |
DIN EN 62619 : 2017 | Identical |
IEC 62619:2017 | Identical |
BS EN 62619:2017 | Identical |
I.S. EN 62619:2017 | Identical |
PN EN 62619 : 2017 | Identical |
NEN EN IEC 62619 : 2017 | Identical |
NF EN 62619 : 2017 | Identical |
SN EN 62619 : 2017 | Identical |
VDE 0510-39 : 2017 | Identical |
UNE-EN 62619:2017 | Identical |
PNE-FprEN 62619 | Identical |
ONORM OVE EN 62619 : 2017 | Identical |
BS EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage. General requirements and methods of test On-grid applications |
17/30338554 DC : 0 | BS EN 1175 - SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS |
EN IEC 62928:2018 | Railway applications - Rolling stock - Onboard lithium-ion traction batteries |
PREN 1175 : DRAFT 2017 | SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS |
I.S. EN 62864-1:2016 | RAILWAY APPLICATIONS - ROLLING STOCK - POWER SUPPLY WITH ONBOARD ENERGY STORAGE SYSTEM - PART 1: SERIES HYBRID SYSTEM |
UNE-EN 62864-1:2017 | Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system |
I.S. EN IEC 62928:2018 | RAILWAY APPLICATIONS - ROLLING STOCK - ONBOARD LITHIUM-ION TRACTION BATTERIES |
EN 62864-1:2016 | Railway applications - Rolling stock - Power supply with onboard energy storage system - Part 1: Series hybrid system |
EN 61427-2:2015 | Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications |
IEC 61025:2006 | Fault tree analysis (FTA) |
EN 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 |
EN 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
IEC 62620:2014 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications |
IEC 62281:2016 | Safety of primary and secondary lithium cells and batteries during transport |
IEC 61960:2011 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications |
EN 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures |
IEC 61511-1:2016+AMD1:2017 CSV | Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
EN 61960-3:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications - Part 3: Prismatic and cylindrical lithium secondary cells, and batteries made from them |
EN 62281:2017 | Safety of primary and secondary lithium cells and batteries during transport |
EN 61434:1996 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Guide to the designation of current in alkaline secondary cell and battery standards |
IEC TR 62660-4:2017 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 4: Candidate alternative test methods for the internal short circuit test of IEC 62660-3 |
EN 62660-2:2011 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 2: Reliability and abuse testing |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
IEC 62660-3:2016 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 3: Safety requirements |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 62660-1:2010 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 1: Performance testing |
EN 61025:2007 | Fault tree analysis (FTA) |
EN 62061:2005/A2:2015 | SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015) |
EN 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels |
ISO 9001:2015 | Quality management systems — Requirements |
EN 62620:2015 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications |
IEC 61434:1996 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Guide to designation of current in alkaline secondary cell and battery standards |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
IEC 62660-2:2010 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 2: Reliability and abuse testing |
EN 61513:2013 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
EN 62133:2013 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.