EN 62220-1-2:2007
Current
The latest, up-to-date edition.
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography
20-09-2007
Specifies the method for the determination of the detective quantum efficiency (DQE) of digital X-ray imaging devices as a function of air kerma and of spatial frequency for the working conditions in the range of the medical application as specified by the manufacturer. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. This Part 1-2 is restricted to digital X-ray imaging devices that are used for mammographic imaging such as but not exclusively, CR systems, direct and indirect flat panel detector based systems, scanning systems (CCD based or photon-counting). This part of IEC 62220 is not applicable to - digital X-ray imaging devices intended to be used in general radiography or in dental radiography; - computed tomography; and - devices for dynamic imaging (where series of images are acquired, as in fluoroscopic or cardiac imaging).
Committee |
CLC/TC 62
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
IEC 62220-1-2:2007 | Identical |
NF EN 62220-1-2 : 2007 | Identical |
NBN EN 62220-1-2 : 2007 | Identical |
NEN EN IEC 62220-1-2 : 2007 | Identical |
I.S. EN 62220-1-2:2007 | Identical |
PN EN 62220-1-2 : 2007 | Identical |
UNE-EN 62220-1-2:2008 | Identical |
BS EN 62220-1-2:2007 | Identical |
CEI EN 62220-1-2 : 2009 | Identical |
DIN EN 62220-1-2:2009-02 | Identical |
EN 62220-1-1:2015 | Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging |
BS EN 62220-1-1:2015 | Medical electrical equipment. Characteristics of digital x-ray imaging devices Determination of the detective quantum efficiency. Detectors used in radiographic imaging |
BS EN 60601-2-45 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES |
I.S. EN 60601-2-45:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES |
EN 60601-2-45:2011/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES (IEC 60601-2-45:2011/A1:2015) |
ISO 12232:2006 | Photography Digital still cameras Determination of exposure index, ISO speed ratings, standard output sensitivity, and recommended exposure index |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
ISO 15529:2010 | Optics and photonics Optical transfer function Principles of measurement of modulation transfer function (MTF) of sampled imaging systems |
EN 60601-2-45:2011/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-45: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT AND MAMMOGRAPHIC STEREOTACTIC DEVICES (IEC 60601-2-45:2011/A1:2015) |
EN 61267:2006 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 62220-1:2003 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1: Determination of the detective quantum efficiency |
ISO 12233:2017 | Photography — Electronic still picture imaging — Resolution and spatial frequency responses |
EN 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 61262-5:1994 | Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
EN 62220-1:2004 | Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1: Determination of the detective quantum efficiency |
IEC 60601-2-45:2011+AMD1:2015 CSV | Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices |