EN 62059-41:2006
Current
The latest, up-to-date edition.
Electricity metering equipment - Dependability - Part 41: Reliability prediction
26-05-2006
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General information
5 Reliability analysis methods
6 Reliability predictions using the parts stress method
6.1 Overview
6.2 Component failure rate data
6.3 Stress models
6.4 Failure rate prediction using the parts stress method
6.5 Phases of the failure rate prediction process
6.6 Presentation of results
7 Other dependability considerations
8 Life time of life-limited components
Annex A (normative) Reliability prediction - Procedural flow
Annex B (informative) Overview of other reliability analysis
and prediction methods
Annex ZA (normative) Normative references to international
publications with there corresponding European
publications
Bibliography
This part of IEC 62059-41 is applicable to all types of static metering equipment for energy measurement and load control.
Committee |
CLC/TC 13
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 62059-41 : 2006 | Identical |
I.S. EN 62059-41:2006 | Identical |
SN EN 62059-41 : 2006 | Identical |
NEN EN IEC 62059-41 : 2006 | Identical |
UNE-EN 62059-41:2006 | Identical |
IEC 62059-41:2006 | Identical |
PN EN 62059-41 : 2006 | Identical |
NBN EN 62059-41 : 2006 | Identical |
VDE 0418-9-41 : 2007 | Identical |
DIN EN 62059-41 : 2007 | Identical |
CEI EN 62059-41 : 2007 | Identical |
BS EN 62059-41:2006 | Identical |
EN 50470-3:2006 | Electricity metering equipment (a.c.) - Part 3: Particular requirements - Static meters for active energy (class indexes A, B and C) |
CEI EN 50470-3 : 2007 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 3: PARTICULAR REQUIREMENTS - STATIC METERS FOR ACTIVE ENERGY (CLASS INDEXES A, B AND C) |
UNE-EN 62059-31-1:2010 | Electricity metering equipment - Dependability -- Part 31-1: Accelerated reliability testing - Elevated temperature and humidity |
BS EN 62059-31-1:2008 | Electricity metering equipment. Dependability Accelerated reliability testing. Elevated temperature and humidity |
CEI EN 62059-31-1 : 2009 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 31-1: ACCELERATED RELIABILITY TESTING - ELEVATED TEMPERATURE AND HUMIDITY |
I.S. EN 50470-3:2006 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 3: PARTICULAR REQUIREMENTS - STATIC METERS FOR ACTIVE ENERGY (CLASS INDEXES A, B AND C) |
BS EN 50470-3 : 2006 | ELECTRICITY METERING EQUIPMENT (A.C.) - PART 3: PARTICULAR REQUIREMENTS - STATIC METERS FOR ACTIVE ENERGY (CLASS INDEXES A, B AND C) |
I.S. EN 62059-31-1:2008 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 31-1: ACCELERATED RELIABILITY TESTING - ELEVATED TEMPERATURE AND HUMIDITY |
EN 62059-31-1 : 2008 | ELECTRICITY METERING EQUIPMENT - DEPENDABILITY - PART 31-1: ACCELERATED RELIABILITY TESTING - ELEVATED TEMPERATURE AND HUMIDITY |
CEI EN 50470-4:2023 | Electricity metering equipment - Part 4: Particular requirements - Static meters for DC active energy (class indexes A, B and C) |
IEC 60605-3-2:1986 | Equipment reliability testing. Part 3: Preferred test conditions. Equipment for stationary use in weatherprotected locations - High degree of simulation |
IEC 60605-4:2001 | Equipment reliability testing - Part 4: Statistical procedures for exponential distribution - Point estimates, confidence intervals, prediction intervals and tolerance intervals |
IEC 62308:2006 | Equipment reliability - Reliability assessment methods |
IEC 60605-3-3:1992 | Equipment reliability testing - Part 3: Preferred test conditions - Section 3: Test Cycle 3: Equipment for stationary use in partially weatherprotected locations - Low degree of simulation |
IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
IEC 61078:2016 | Reliability block diagrams |
IEC 61165:2006 | Application of Markov techniques |
IEC TR 62059-21:2002 | Electricity metering equipment - Dependability - Part 21: Collection of meter dependability data from the field |
IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
IEC 60605-2:1994 | Equipment reliability testing - Part 2: Design of test cycles |
EN 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
IEC TR 62059-11:2002 | Electricity metering equipment - Dependability - Part 11: General concepts |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.