EN 61466-2:1998/A1:2002

Current

Current

The latest, up-to-date edition.

COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - PART 2: DIMENSIONAL AND ELECTRICAL CHARACTERISTICS

Published date

15-03-2002

Sorry this product is not available in your region.

FOREWORD
1 Scope
2 Normative references
3 Mechanical and dimensional characteristics
4 Electrical characteristics
5 Designation
6 Marking
7 Tolerances
Annex A (informative) Information on creepage distance
Annex ZA (normative) Normative references to international
                       publications with their corresponding
                       European publications

Applies to composite string insulators having a specific mechanical load (SML) of 40 kN and 70 kN for a.c. overhead distribution lines, having a nominal voltage in excess of 1000 V and frequency not in excess of 100 Hz.

Committee
SR 36
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

UNE-EN 50341-1:2017 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS

IEC 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength and end fittings
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
HD 540.2 : 200S1 INSULATION COORDINATION - APPLICATION GUIDE
EN 61466-1:2016 Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules