EN 61378-1:2011
Current
The latest, up-to-date edition.
Convertor transformers - Part 1: Transformers for industrial applications
11-11-2011
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and acronyms
4 Classification
5 Ratings
6 Load loss and voltage drop in transformers
and reactors
7 Tests for converter transformers
8 On load noise level with transductors
and/or IPT
Annex A (informative) - Determination of transformer
service load loss at rated non-sinusoidal
converter current from measurements with
rated transformer current of fundamental
frequency
Annex B (informative) - Short-circuit test currents
and load losses in transformers for single-way
converters (total loss injection)
Annex C (informative) - Current sharing measurement
in high current valve windings
Annex D (informative) - Examples of duty cycles
Annex E (informative) - Guidelines for design review
Annex F (informative) - Determination of loss in
transformer tank due to magnetic field. 3D
simulation and guidelines for tank losses
evaluation and tank hotspot calculation
Annex G (informative) - Short-circuit measurements of
rectifier transformers equipped with built in
transductors
Annex H (informative) - Determination of the transformer
voltage ratio and phase displacement by the
turn ratio measurements
Annex I (informative) - Phase displacement connections
and terminal indications of converter transformers
Annex J (normative) - Correlation between IEC 61378-1
and IEC 60146-1-1 ratings
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 61378-1:2011(E) deals with the specification, design and testing of power transformers and reactors which are intended for integration within semiconductor converter plants. The scope of this International Standard is limited to application of power converters of any power rating. Typical applications are: thyristor rectifiers for electrolysis; diode rectifiers for electrolysis; thyristor rectifiers for large drives; thyristor rectifiers for scrap melting furnaces, and diode rectifiers feeding inverters for variable speed drives. The standard also covers the regulating unit utilized in such application as step down regulating transformers or autotransformers. This edition includes the following significant technical changes with respect to the previous edition: - addition of winding connections with phase displacement (30°); - addition of transformers with more than one active part in the same tank; - change of reference power definition; - addition of regulating transformer feeding converter transformer; - addition of considerations about current sharing and hot spot temperature in high current windings for various winding arrangements; - addition of transductors used for d.c. voltage regulation together with diode rectifiers. The contents of the corrigendum of January 2012 have been included in this copy.
Committee |
CLC/TC 14
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
IEC 61378-1:2011 | Identical |
NBN EN 61378-1 : 2012 | Identical |
NF EN 61378-1 : 2014 | Identical |
NEN EN IEC 61378-1 : 2011 | Identical |
I.S. EN 61378-1:2011 | Identical |
PN EN 61378-1 : 2011 | Identical |
SN EN 61378-1 : 1998 | Identical |
DIN EN 61378-1 : 2012 | Identical |
VDE 0532-41 : 2012 | Identical |
UNE-EN 61378-1:2012 | Identical |
BS EN 61378-1:2011 | Identical |
CEI EN 61378-1 : 2012 | Identical |
BS EN 50329 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
CEI EN 60076-14 : 2014 | POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS |
CEI EN 61378-2 : 2002 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
I.S. EN 60076-14:2013 | POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV)) |
BS EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV General requirements |
BS EN 60076-14:2013 | Power transformers Liquid-immersed power transformers using high-temperature insulation materials |
UNE-EN 60076-14:2014 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
CEI EN 60076-16 : 2012 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS |
VDE 0532-42 : 2001 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
I.S. EN 50588-1:2017 | MEDIUM POWER TRANSFORMERS 50 HZ, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60310:2016 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK |
BS EN 61800-4:2003 | Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV |
BS EN 60076-16:2011 | Power transformers Transformers for wind turbines applications |
UNE-EN 60076-16:2012 | Power transformers - Part 16: Transformers for wind turbines applications |
EN 50588-1:2017 | Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements |
BS EN 60310:2016 | Railway applications. Traction transformers and inductors on board rolling stock |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
I.S. EN 60076-16:2011 | POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011) |
I.S. EN 50329:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
CEI EN 61800-4 : 2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
I.S. EN 61800-4:2003 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 61800-4:2003 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
EN 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
EN 60310:2016/AC:2018-03 | RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018) |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC TR 60616:1978 | Terminal and tapping markings for power transformers |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
IEC TR 60146-1-2:2011 | Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 61378-3:2015 | Converter transformers - Part 3: Application guide |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC TS 60076-14:2009 | Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
Access your standards online with a subscription