EN 61264:1998/corrigendum:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
01-08-2003
12-01-2013
Contents
Foreword
Introduction
Clause
1. Scope and object
2. Normative references
3. Definitions
4. General recommendations for design and construction
4.1 Purpose
4.2 Rules for design
5. General requirements for tests
5.1 Classification of tests
5.2 General requirements for pressure tests
5.3 General requirements for bending tests
6. Type tests
6.1 General
6.2 Pressure test
6.3 Bending test
7. Sample tests
7.1 Selection and number of test pieces
7.2 Tests
7.3 Re-test procedure
7.4 Verification of dimensions
7.5 Control of the roughness of ground parts
7.6 Mechanical test (for assembled hollow insulators)
8. Routine tests
8.1 General
8.2 Mechanical tests
8.3 Other tests
9. Documentation
9.1 Marking
9.2 Certificates
Annexes
A (informative) Tolerances of form and position
B (informative) Bending moment equivalent to the design
pressure
C (informative) Bibliography
Annex ZA (normative) Normative references to
international publications
with their corresponding
European publications
Applicable to hollow insulators made from ceramic material, with their fixing devices, to be used with a permanent gas pressure in excess of 50 kPa gauge with an internal volume equal to or greater than 1 I(1000cm x cm x cm).
Committee |
SR 36C
|
DevelopmentNote |
This Standard supersedes EN 50062:1991 (02/2001) Also numbered as IEC 61264. (06/2001)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
VDE 0674-3 : 99 COR 1 1999 | Identical |
BS EN 61264:1999 | Identical |
NF EN 61264 : 2000 | Identical |
NEN EN IEC 61264 : 1999 C11 2000 | Identical |
IEC 61264:1998 | Identical |
I.S. EN 61264:1999 | Identical |
NBN EN 61264 : 1999 | Identical |
CEI EN 61264 : 1999 COR 1 2001 | Identical |
SN EN 61264 : 1998 | Identical |
BS EN 62271-203:2012 | High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
DIN EN 45510-2-7:2003-12 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
UNE-EN 62271-203:2013 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
VDE 0674-1 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
DIN EN 60168 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
08/30179468 DC : DRAFT MAR 2008 | BS EN 62271-203 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 45510-2-7:2002 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
CEI EN 62271-203 : 2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
I.S. EN 62271-203:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV)) |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
ISO 4287:1997 | Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions and surface texture parameters |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 60672-3:1997 | Ceramic and glass-insulating materials - Part 3: Specifications for individual materials |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC 60865-1:2011 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
EN 50062:1991 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
ISO 4287-2:1984 | Surface roughness — Terminology — Part 2: Measurement of surface roughness parameters |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.