EN 60691:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Thermal-links - Requirements and application guide
26-11-2019
07-10-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Documentation
9 Constructional requirements
10 Electrical requirements
11 Temperature tests
12 Resistance to rusting
13 Manufacturers validation programme
Annex A (normative) - Application guide
Annex B (normative) - Alternative ageing test for thermal-links
with Th greater than 250 degrees C for use in electric irons
Annex C (normative) - Conductive heat ageing test
Annex D (informative) - Extended holding temperature evaluation
Annex E (normative) - Seal ageing test
Annex F (normative) - Identification requirements
Annex G (normative) - Indelibility of markings
Annex H (normative) - Requirements for thermal-link
packaged assemblies
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60694:2015 is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal conditions. This standard may be applicable to thermal-links for use under conditions other than indoors, provided that the climatic and other circumstances in the immediate surroundings of such thermal-links are comparable with those in this standard. This standard may be applicable to thermal-links in their simplest forms (e.g. melting strips or wires), provided that molten materials expelled during function cannot adversely interfere with the safe use of the equipment, especially in the case of hand-held or portable equipment, irrespective of its position. Annex H of this standard is applicable to thermal-link packaged assemblies where the thermal-link(s) has already been approved to this standard but packaged in a metallic or non-metallic housing and provided with terminals/wiring leads. This standard is applicable to thermal-links with a rated voltage not exceeding 690 V a.c. or d.c. and a rated current not exceeding 63 A. The objectives of this standard are: to establish uniform requirements for thermal-links, to define methods of test, to provide useful information for the application of thermal-links in equipment. This standard is not applicable to thermal-links used under extreme conditions such as corrosive or explosive atmospheres. This standard is not applicable to thermal-links to be used in circuits on a.c. with a frequency lower than 45 Hz or higher than 62 Hz. This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2010. This fourth edition constitutes a technical revision. This fourth edition includes the following significant technical changes with respect to the previous edition:- requirements for thermal-link packaged assemblies;- renew the requirements and definitions for Th-test;- change starting temperature for interrupt current test;- clarify requirements for marking (packing label);- minimum Proof Tracking Index 175 instead 120. Keywords: thermal protection of equipment, thermal-links
Committee |
CLC/SR 32C
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 60691 : 2016 | Identical |
IEC 60691:2015 | Identical |
NBN EN 60691 : 2003 AMD 2 2010 | Identical |
NEN EN IEC 60691 : 2016 | Identical |
NEN EN 60691 : 1990 | Identical |
I.S. EN 60691:2016 | Identical |
PN EN 60691 : 2016 | Identical |
SN EN 60691 : 2016 | Identical |
VDE 0821 : 2017 | Identical |
DIN EN 60691 : 2017 | Identical |
UNE-EN 60691:2016 | Identical |
UNE-EN 60691:2004 | Identical |
BS EN 60691:2016 | Identical |
DS EN 60691 : 2016 | Identical |
ONORM OVE EN 60691 : 2017 | Identical |
PNE-FprEN 60691 | Identical |
BS 7283:1990 | Identical |
NEN 10691 : 1996 | Identical |
UNE 20491:1992 | Identical |
NBN C 61 691 : 1990 | Identical |
12/30258455 DC : 0 | FPREN 60065:2011+FPRAA - AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS |
EN IEC 61058-1:2018 | Switches for appliances - Part 1: General requirements |
BS EN 60922:1997 | Auxiliaries for lamps. Ballasts for discharge lamps (excluding tubular fluorescent lamps). General and safety requirements |
BS EN 62368-1 : 2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
DIN EN 60922 : 1997 | AUXILIARIES FOR LAMPS - BALLASTS FOR DISCHARGE LAMPS (EXCLUDING TUBULAR FLUORESCENT LAMPS) - GENERAL AND SAFETY REQUIREMENTS |
BS EN 60920:1991 | Ballasts for tubular fluorescent lamps. General and safety requirements |
I.S. EN 60730-2-9:2010 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-9: PARTICULAR REQUIREMENTS FOR TEMPERATURE SENSING CONTROLS |
I.S. EN 61347-1:2015 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
BS EN 61558-1 : 2005 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust Protection by encapsulation \'mD\' |
BS EN 61347-1:2015 | Lamp controlgear General and safety requirements |
BS EN 60079-18 : 2015 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 60079-31:2014 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
UNE-EN 60079-31:2016 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
BS EN 61058-1 : 2002 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61058-1:2002 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
DIN EN 61046 : 1995 AMD 1 1997 | D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
CEI EN 62368-1 : 2016 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
BS EN 60079-31:2014 | Explosive atmospheres Equipment dust ignition protection by enclosure \'t\' |
BS EN 60335-1 : 2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
CEI EN 60079-18 : 2016 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' |
BS EN 60065 : 2014 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014, MODIFIED) |
UNE-EN 61347-1:2016 | Lamp controlgear - Part 1: General and safety requirements |
BS EN 60730-2-9:2010 | Automatic electrical controls for household and similar use Particular requirements for temperature sensing controls |
UNE-EN 60065:2015 | Audio, video and similar electronic apparatus - Safety requirements |
CEI EN 61347-1 : 2016 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
12/30258453 DC : 0 | BS EN 62368-1 AMD - AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
I.S. EN 60335-1:2012 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS |
I.S. EN 60065:2014 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS |
I.S. EN 62368-1:2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
EN 62368-1:2014/AC:2017-03 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
I.S. EN 61558-1:2006 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 60335-1:2012 | Household and similar electrical appliances - Safety - Part 1: General requirements |
EN 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation "mD" |
07/30174056 DC : 0 | BS EN 60065 - AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS |
CEI EN 60730-2-9 : 2012 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-9: PARTICULAR REQUIREMENTS FOR TEMPERATURE SENSING CONTROLS |
DIN EN 60920 : 1993 AMD 11 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS |
EN 60079-18:2015/A1:2017 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' (IEC 60079-18:2014/A1:2017) |
I.S. EN 60079-18:2015 | EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' |
I.S. EN 60079-31:2014 | EXPLOSIVE ATMOSPHERES - PART 31: EQUIPMENT DUST IGNITION PROTECTION BY ENCLOSURE 'T' |
EN 60730-2-9:2010 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
UNE-EN 60730-2-9:2012 | Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN 60127-1:2006/A2:2015 | MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
IEC 60695-10-3:2016 | Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
EN 60216-5:2008 | Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
EN 60695-10-3:2016 | Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60216-5:2008 | Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-