EN 60512-11-3:2002

Current

Current

The latest, up-to-date edition.

Connectors for electronic equipment - Tests and measurements - Part 11-3: Climatic tests - Test 11c: Damp heat, steady state

Published date

17-04-2002

Foreword
1 General
2 Preparation
3 Test method
4 Details to be specified
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Defines a standard test method to assess the ability of components (essentially connectors) to be stored and/or to function in a specified manner under conditions of high relative humidity.

Committee
CLC/SR 48B
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

BS EN 61076-3-122:2017 Connectors for electrical and electronic equipment. Product requirements Detail specification for 8-way, shielded, free and fixed connectors for I/O and Gigabit Ethernet applications in harsh environments
BS EN 60130-9:2011 Connectors for frequencies below 3 MHz Circular connectors for radio and associated sound equipment
UNE-EN 50467:2012 Railway applications - Rolling stock - Electrical connectors, requirements and test methods
I.S. EN 60130-9:2011 CONNECTORS FOR FREQUENCIES BELOW 3 MHZ - PART 9: CIRCULAR CONNECTORS FOR RADIO AND ASSOCIATED SOUND EQUIPMENT
I.S. EN 50467:2011 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
CEI EN 50467 : 2013 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
PREN 50467 : DRAFT 2009 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
EN 61076-3-122:2017 Connectors for electrical and electronic equipment - Product requirements - Part 3-122: Detail specification for 8-way, shielded, free and fixed connectors for I/O and Gigabit Ethernet applications in harsh environments
DD CLC/TS 50467:2008 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
S.R. CLC/TS 50467:2008 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
EN IEC 61076-3-119:2018 Connectors for electrical and electronic equipment - Product requirements - Part 3-119: Rectangular connectors - Detail specification for shielded and unshielded, free and fixed 10-way connectors with push-pull coupling for industrial environments for data transmission with frequencies up to 100 MHz
CEI EN 61076-3-122 : 1ED 2017 CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-122: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR I/O AND GIGABIT ETHERNET APPLICATIONS IN HARSH ENVIRONMENTS
I.S. EN 61076-3-122:2017 CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-122: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR I/O AND GIGABIT ETHERNET APPLICATIONS IN HARSH ENVIRONMENTS
CLC/TS 50467 : 2008 COR 2008 RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
09/30208429 DC : 0 BS EN 50467 - RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS
BS EN 50467:2011 Railway applications. Rolling stock. Electrical connectors, requirements and test methods
CEI EN 60130-9 : 2012 CONNECTORS FOR FREQUENCIES BELOW 3 MHZ - PART 9: CIRCULAR CONNECTORS FOR RADIO AND ASSOCIATED SOUND EQUIPMENT
I.S. EN IEC 61076-3-119:2018 CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-119: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR SHIELDED AND UNSHIELDED, FREE AND FIXED 10-WAY CONNECTORS WITH PUSH-PULL COUPLING FOR INDUSTRIAL ENVIRONMENTS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 100 MHZ
EN 60130-9:2011 Connectors for frequencies below 3 MHz - Part 9: Circular connectors for radio and associated sound equipment
EN 50467:2011 Railway applications - Rolling stock - Electrical connectors, requirements and test methods

IEC 60512-3-1:2002 Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance
IEC 60512-7:1993 Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests
HD 323.2.3 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
IEC 60512-1-1:2002 Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination
IEC 60512-2-1:2002 Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method
EN 60512-3-1:2002 Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance
IEC 60512-4-1:2003 Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof
EN 60512-1-1:2002 Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination
EN 60512-2-1:2002 Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method

Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.