EN 60230:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Impulse tests on cables and their accessories
01-03-2018
10-04-2002
SECTION ONE - GENERAL
1 Object and scope
2 Characteristics of the test installation to be
subjected to the tests
3 State of the test installation
4 Shape of the impulse waves
5 Calibration of impulse generator
SECTION TWO - WITHSTAND TESTS
6 Application of the impulses at the level specified
SECTION THREE - TESTS ABOVE THE WITHSTAND LEVEL
7 Application of impulse test above the specified withstand
level and omission of power-frequency test
8 Procedure for tests above the withstand level
Lays down the conditions and procedure for carrying out impulse tests on cables and their accessories, with a view to rationalizing the practice in different laboratories, and thus to facilitate valid comparisons between the results obtained on cables made to different specifications. Notes: 1.This publication should be read in conjunction with EN 60060 and 60141. 2.For voltage measurements with sphere-gaps, see EN 60052.
Committee |
CLC/TC 20
|
DevelopmentNote |
Supersedes HD 48. (06/2002) Redesignated as EN IEC 60230. (03/2018)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 60230 : 2003 | Identical |
PN EN 60230 : 2003 | Identical |
VDE 0481-230 : 2003 | Identical |
CEI EN 60230 : 2006 | Identical |
SN EN 60230 : 2002 | Identical |
IEC 60230:1966 | Identical |
UNE-EN 60230:2002 | Identical |
BS EN 60230:2002 | Identical |
OVE/ONORM EN 60230 : 2003 | Identical |
NBN EN 60230 : 2002 | Identical |
DIN EN 60230 : 2003 | Identical |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
CEI EN 60229 : 2010 | ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION |
I.S. HD 605:2008 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
BS EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
I.S. EN 61442:2005 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
I.S. EN 60229:2008 | ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
EN 60229:2008 | Electric cables - Tests on extruded oversheaths with a special protective function |
EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
ESPECIFICACION UNE 0051:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3). |
EA 0051:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
ESPECIFICACION UNE 0052:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
CEI 20-60 : 1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO INCLUDING 20,8/36 (42) KV |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
CEI EN 61442 : 2006 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV) |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
UNE 211632-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods |
CEI 20-66 : 2010 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.