• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50363-8 : 2005 AMD 1 2011

Current

Current

The latest, up-to-date edition.

INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS

Published date

18-03-2011

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Properties
Tables

Defines the requirements for the physical properties of the harmonised halogen-free thermoplastic sheathing compound.

Committee
CLC/TC 20
DevelopmentNote
To be read in conjunction with EN 50363-0. (12/2005)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
08/30188833 DC : 0 BS EN 50525-3-11 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
BS EN 50525-3-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
PREN 50525-3-11 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 50525-3-11:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE

IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
HD 22.10 S2:2007 Cables of rated voltages up to and including 450/750 V and having cross-linked insulation - Part 10: EPR insulated and polyurethane sheathed flexible cables
EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
HD 22.15 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
HD 21.14 : 2003 CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 14: FLEXIBLE CABLES (CORDS), INSULATED AND SHEATHED WITH HALOGEN-FREE THERMOPLASTIC COMPOUNDS
HD 21.15 : 200S1 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 15: SINGLE CORE CABLES, INSULATED WITH HALOGEN-FREE THERMOPLASTIC COMPOUND, FOR FIXED WIRING
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
IEC 60811-3-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.