• Shopping Cart
    There are no items in your cart
Please Select Your Option.
It seems you are away from your “home” country. Do you wish to be re-directed to your “home” store? If you choose “YES”, you will see product, taxation, and shipping information relevant to your country. If you select “NO”, the current store's conditions will apply.
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50289-3-9:2001

Current

Current

The latest, up-to-date edition.

Communication cables - Specifications for test methods - Part 3-9: Mechanical test methods - Bending tests

Published date

28-08-2001

1 Scope
2 Normative references
3 Definitions
4 Single bending
    4.1 Equipment
    4.2 Test sample
        4.2.1 Optical cables
        4.2.2 Coaxial cables
        4.2.3 Symmetrical cables
    4.3 Procedure
        4.3.1 Procedure 1
        4.3.2 Procedure 2
    4.4 Requirements
    4.5 Test report
5 Repeated bending
    5.1 Equipment
    5.2 Test sample
        5.2.1 Sample length
        5.2.2 Termination
    5.3 Procedure
    5.4 Requirements
    5.5 Test report
6 Flexing
    6.1 Equipment
    6.2 Test sample
    6.3 Procedure
    6.4 Requirements
    6.5 Test report
7 Flexing endurance
    7.1 Equipment
    7.2 Test sample
    7.3 Procedure
    7.4 Requirements
    7.5 Test report
8 Cable bending under tension (dynamic test)
    8.1 Equipment
    8.2 Test sample
    8.3 Procedure
        8.3.1 Procedure 1
        8.3.2 Procedure 2
    8.4 Requirements
    8.5 Test report
9 Stiffness
    9.1 Introduction
    9.2 Equipment
        9.2.1 Method A
        9.2.2 Method B
        9.2.3 Method C
    9.3 Test sample
    9.4 Procedure
        9.4.1 Method A
        9.4.2 Method B
        9.4.3 Method C
    9.5 Requirements
    9.6 Test report
10 Kink test
    10.1 Sample
    10.2 Equipment
    10.3 Procedure
    10.4 Requirement
    10.5 Test report

This Part 3-9 of EN 50289 details the methods of test to determine the bending tests used in analogue and digital communication systems to:-bending around a test mandrel (clause 4);-repeated bending (clause 5);-repeated flexing in service (clause 6);-flexing in service (clause 7);-bending around rollers or bows during installation (clause 8); and-measure the stiffness (clause 9) of such a cable;-kink test (clause 10).It is to be read in conjunction with Part 3-1 of EN 50289, which contains essential provisions for its application.

Committee
CLC/TC 46X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

I.S. EN 50441-1:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
15/30332390 DC : 0 BS EN 50117-10-1 - COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50290-4-2 : DRAFT 2013 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
PREN 50288-11-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
15/30332399 DC : 0 BS EN 50117-11-2 - COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ
10/30215871 DC : 0 BS EN 50441-4 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
BS EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables characterised up to 500 MHz. Horizontal and building backbone cables
BS EN 50441-3:2006 Cables for indoor residential telecommunication installations Screened cables. Grade 3
10/30216201 DC : 0 BS EN 50882-11 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERISED UP TO 500 MHZ, FOR HORIZONTAL AND BUILDING BACKBONE WIRING
BS EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
07/30169496 DC : 0 EN 50117-4-1 - COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
10/30215867 DC : 0 BS EN 50441-2 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
PREN 50288-9-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
I.S. EN 50117-4-2:2015 COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLED DISTRIBUTION NETWORKS
I.S. EN 50288-11-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES, CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50441-4:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
I.S. EN 50288-10-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
I.S. EN 50117-2-3:2004 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
CEI EN 50441-2 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
I.S. EN 50288-8:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
EN 50117-2-2:2004/A2:2013 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
EN 50441-3:2006 Cables for indoor residential telecommunication installations - Part 3: Screened cables - Grade 3
EN 50290-2-37:2016 Communication cables - Part 2-37: Common design rules and construction - Polyethylene insulation for coaxial cables
EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
EN 50117-4-1 : 2008 AMD 1 2013 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
EN 50441-4:2012 Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3
EN 50441-1:2012 Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1
EN 50117-2-4 : 2004 AMD 2 2013 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 9-2: Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
EN 50117-2-5:2004/A2:2013 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
10/30216235 DC : 0 BS EN 50288-10 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50441-4:2012 Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3
14/30296669 DC : 0 BS EN 50117-4-2 - COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLES DISTRIBUTION NETWORKS
BS EN 50288-9-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized from 1 MHz up to 1 000 MHz for work area, patch cord and data centre applications
04/30117159 DC : DRAFT JUL 2004 EN 50441-2 - SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: GRADE 2
UNE-EN 50117-4-1:2010 Coaxial cables - Part 4-1: Sectional specification for cables for BCT cabling in accordance with EN 50173 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz
17/30350080 DC : 0 BS EN 50441-5 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 5: CABLES UP TO 2200 MHZ FOR ONE PAIR AND REMAINING PAIRS UP TO 1000 MHZ
15/30332369 DC : 0 BS EN 50117-9-1 - COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
CEI EN 50441-3 : 2006 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: SCREENED CABLES - GRADE 3
08/30165949 DC : DRAFT JULY 2008 BS EN 50288-8 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 8: SPECIFICATION FOR TYPE 1 CABLES CHARACTERISED UP TO 2 MHZ
BS EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
PREN 50288-10 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10: SECTIONAL SPECIFICATION FOR CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
PREN 50288-9-1 : DRAFT 2010 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
CEI EN 50173-1 : 2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
UNE-EN 50117-4-2:2015 Coaxial cables - Part 4-2: Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
PREN 50441-4 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
UNE-EN 50288-11-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
CEI EN 50290-2-37 : 1ED 2017 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
I.S. EN 50288-9-2:2015 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ FOR WORK AREA, PATCH CORD AND DATA CENTRE APPLICATIONS
CEI EN 50290-2-38 : 1ED 2017 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION FOR COAXIAL CABLES
15/30332393 DC : 0 BS EN 50117-10-2 - COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
PREN 50441-2 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
BS EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control Specification for type 1 cables characterised up to 2 MHz
BS EN 50290-4-2:2014 Communication cables General considerations for the use of cables. Guide to use
BS EN 50288-9-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterised up to 1 000 MHz. Horizontal and building backbone cables
BS EN 50290-2-38:2016 Communication cables Common design rules and construction. Polypropylene insulation for coaxial cables
13/30293741 DC : 0 BS EN 50290-2-37 - COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
10/30215863 DC : 0 BS EN 50441-1 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
04/30117162 DC : DRAFT JUL 2004 EN 50441-3 - SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: GRADE 3
BS EN 50441-2:2012 Cables for indoor residential telecommunication installations Screened cables. Grade 1
15/30332386 DC : 0 BS EN 50117-9-3 - COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ
BS EN 50290-2-37:2016 Communication cables Common design rules and construction. Polyethylene insulation for coaxial cables
UNE-EN 50288-10-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 10-1: Sectional specification for screened cables characterized up to 500 MHz - Horizontal floor and building backbone cables
PREN 50441-5 : DRAFT 2017 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 5: CABLES UP TO 2200 MHZ FOR ONE PAIR AND REMAINING PAIRS UP TO 1000 MHZ
I.S. EN 50288-9-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERISED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
04/30117156 DC : DRAFT JUL 2004 EN 50441-1 - UN-SCREENED CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: GRADE 1
BS EN 50117-1 : 2002 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
PREN 50117-11-2 : DRAFT 2015 COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ
BS EN 50117-4-1 : 2008 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
I.S. EN 50441-2:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
I.S. EN 50290-2-38:2016 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION FOR COAXIAL CABLES
PREN 50290-2-38 : DRAFT 2013 COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
BS EN 50117-2-3 : 2004 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
I.S. EN 50441-3:2006 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 3: SCREENED CABLES - GRADE 3
BS EN 50173-1:2011 Information technology. Generic cabling systems General requirements
I.S. EN 50288-10-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 10-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 500 MHZ - HORIZONTAL FLOOR AND BUILDING BACKBONE CABLES
UNE-EN 50288-8:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz
UNE-EN 50290-2-38:2016 Communication cables - Part 2-38: Common design rules and construction - Polypropylene insulation for coaxial cables
CEI EN 50441-1 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
EN 50173-1:2011 Information technology - Generic cabling systems - Part 1: General requirements
PREN 50441-1 : DRAFT 2010 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1
EN 50117-1 : 2002 AMD 2 2013 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
13/30260675 DC : 0 BS EN 50288-10-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
PREN 50117-10-1 : DRAFT 2015 COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
15/30332396 DC : 0 BS EN 50117-11-1 - COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50117-10-2 : DRAFT 2015 COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
13/30268920 DC : 0 BS EN 50290-4-2 ED.2 PREN 50290-4-2 ED.2 - COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
13/30277706 DC : 0 BS EN 50288-11-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-2: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
13/30260672 DC : 0 BS EN 50288-9-2 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 9-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 1000 MHZ - WORK AREA, PATCH CORD AND DATA CENTRE CABLES
BS EN 50117-2-5 : 2004 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MZ
PREN 50117-9-3 : DRAFT 2015 COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ
BS EN 50288-10-1:2012 Multi-element metallic cables used in analogue and digital communication and control Sectional specification for screened cables characterized up to 500 MHz. Horizontal floor and building backbone cables
I.S. EN 50117-2-4:2004/A2:2013 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
UTEC 93 531-15 : 2008 INDOOR COMMUNICATION SCREENED CABLE - SCREENED CABLES FOR INDOOR COMMUNICATIONS - RADIOFREQUENCY TELEVISION APPLICATIONS INCLUDING SATELLITE INTERMEDIATE BAND
I.S. EN 50288-11-1:2012 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATION AND CONTROL - PART 11-1: SECTIONAL SPECIFICATION FOR UN-SCREENED CABLES CHARACTERISED UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
I.S. EN 50290-2-37:2016 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
BS EN 50117-2-2 : 2004 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
I.S. EN 50117-4-1:2008 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
PREN 50290-2-37 : DRAFT 2013 COMMUNICATION CABLES - PART 2-37: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
PREN 50288-10-2 : DRAFT 2013 MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 10-2: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED FROM 1 MHZ UP TO 500 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
CEI EN 50441-4 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
I.S. EN 50117-2-5:2004 COAXIAL CABLES - PART 2-5: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
I.S. EN 50290-4-2:2014 COMMUNICATION CABLES - PART 4-2: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - GUIDE TO USE
I.S. EN 50117-2-2:2004 COAXIAL CABLES - PART 2-2: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
UNE-EN 50290-4-2:2016 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
I.S. EN 50173-1:2011 INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS
PREN 50117-11-1 : DRAFT 2015 COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
PREN 50117-9-1 : DRAFT 2015 COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
10/30216188 DC : 0 BS EN 50288-9-1 - MULTI-ELEMENT METALLIC CABLES USED IN ANALOGUE AND DIGITAL COMMUNICATIONS AND CONTROL - PART 9-1: SECTIONAL SPECIFICATION FOR SCREENED CABLES CHARACTERIZED UP TO 1000 MHZ - HORIZONTAL AND BUILDING BACKBONE CABLES
BS EN 50117-4-2:2015 Coaxial cables Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
BS EN 50117-2-4 : 2004 COAXIAL CABLES - PART 2-4: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MZ
BS EN 50441-1:2012 Cables for indoor residential telecommunication installations Unscreened cables. Grade 1
UNE-EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
15/30332377 DC : 0 BS EN 50117-9-2 - COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
13/30293745 DC : 0 BS EN 50290-2-38 - COMMUNICATION CABLES - PART 2-38: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR COAXIAL CABLES
PREN 50117-4-2 : DRAFT 2014 COAXIAL CABLES - PART 4-2: SECTIONAL SPECIFICATION FOR CATV CABLES UP TO 6 GHZ USED IN CABLES DISTRIBUTION NETWORKS
PREN 50117-9-2 : DRAFT 2015 COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
UNE-EN 50290-2-37:2016 Communication cables - Part 2-37: Common design rules and construction - Polyethylene insulation for coaxial cables
UNE-EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
UNE-EN 50288-9-1:2013 Multi-element metallic cables used in analogue and digital communication and control - Part 9-1: Sectional specification for screened cables characterised up to 1 000 MHz - Horizontal and building backbone cables
I.S. EN 50117-1:2002 COAXIAL CABLES - PART 1: GENERIC SPECIFICATION
EN 50288-11-1:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 11-1: Sectional specification for un-screened cables characterised up to 500 MHz - Horizontal and building backbone cables
EN 50288-10-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 10-2: Sectional specification for screened cables characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 50117-2-3:2004/A2:2013 COAXIAL CABLES - PART 2-3: SECTIONAL SPECIFICATION FOR CABLES USED IN CABLED DISTRIBUTION NETWORKS - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ
EN 50290-4-2:2014 Communication cables - Part 4-2: General considerations for the use of cables - Guide to use
EN 50117-4-2:2015 Coaxial cables - Part 4-2: Sectional specification for CATV cables up to 6 GHz used in cabled distribution networks
EN 50288-11-2:2015 Multi-element metallic cables used in analogue and digital communication and control - Part 11-2: Sectional specification for un-screened cables, characterized from 1 MHz up to 500 MHz for work area, patch cord and data centre applications
EN 50290-2-38:2016 Communication cables - Part 2-38: Common design rules and construction - Polypropylene insulation for coaxial cables
EN 50441-2:2012 Cables for indoor residential telecommunication installations - Part 2: Screened cables - Grade 1
EN 50288-8:2012 Multi-element metallic cables used in analogue and digital communication and control - Part 8: Specification for type 1 cables characterised up to 2 MHz

EN 50289-3-1:2001 Communication cables - Specifications for test methods - Part 3-1: Mechanical test methods - General requirements
EN 50290-1-2:2004 Communication cables - Part 1-2: Definitions

Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.