EN 50131-4:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices
09-05-2019
04-06-2009
1 Scope
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 General considerations
5 Requirements
5.1 Functional
5.2 Tamper
5.3 Environmental
5.4 EMC
5.5 Safety
5.6 Electrical
5.7 Self test requirements
5.8 Marking
5.9 Documentation
6 Test section
6.1 Functional
6.2 Reduced functional test
6.3 Response to events
6.4 Acoustic
6.5 Tamper
6.6 Electrical tests
6.7 Marking
6.8 Documentation
6.9 Environmental
Annex A (normative) Sound level test for warning devices
Annex B (informative) Example remote test protocol
This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requirements are also given for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Committee |
CLC/TC 79
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
VDE 0830-2-4 : 2010 | Identical |
I.S. EN 50131-4:2009 | Identical |
DIN EN 50131-4 : 2010 | Identical |
NBN EN 50131-4 : 2009 | Identical |
SN EN 50131-4 : 2009 | Identical |
BS EN 50131-4:2009 | Identical |
PN EN 50131-4 : 2010 | Identical |
UNE-EN 50131-4:2010 | Identical |
NEN EN 50131-4 : 2009 | Identical |
CEI EN 50131-4 : 2010 | Identical |
NF EN 50131-4 : 2009 | Identical |
CEI 79-3 : 2012 | ALARM SYSTEMS - PARTICULAR REQUIREMENTS FOR INTRUSION AND HOLD-UP INSTALLATIONS |
CEI UNI EN 50518-1 : 2015 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
PREN 14604 : DRAFT 2016 | SMOKE ALARM DEVICES |
UNI CEI EN 50518-1 : 2014 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
16/30315066 DC : 0 | BS EN 14604 - SMOKE ALARM DEVICES |
UNE-EN 50518-1:2014 | Monitoring and alarm receiving centre - Part 1: Location and construction requirements |
BS EN 50518-1:2013 | Monitoring and alarm receiving centre Location and construction requirements |
TR 103 056 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS |
I.S. EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.