Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT)
06-06-2014
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
5 Security grade
6 Environmental performance
7 Functional requirements
8 Product documentation
9 Marking and labelling
10 Tests
Annex A (informative) - Classification of SPT
Bibliography
This European Standard specifies requirements for SPT used in I&HAS to transmit alarm and other messages to a location remote from the supervised premises.
NOTE 1Requirements for the transmission of alarms are given in the EN/TS 50136 series of standards. EN 50136 2 gives requirements for SPT for use in any type of alarm system (e.g. fire, social care, intrusion, etc).
This European Standard gives specific requirements for SPT used in Intrusion and Hold-up Alarm Systems (I&HAS) and should be used in combination with EN 50136 2.
The requirements of this European Standard apply to different types of SPT including separate SPT, SPT located within the housings of other I&HAS components and also when the SPT functionality is integrated with the CIE or other parts of an I&HAS.
NOTE 2To facilitate the differing requirements this European Standard includes a categorisation with three types (X, Y and Z).
This European Standard does not give requirements for the ATS network or performance.
Committee |
CLC/TC 79
|
DevelopmentNote |
Supersedes PREN 50131-10. (06/2014)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 50131-10:2014 | Identical |
NF EN 50131-10 : 2014 | Identical |
I.S. EN 50131-10:2014 | Identical |
CEI EN 50131-10 : 2015 | Identical |
DIN EN 50131-10 : 2015-03 | Identical |
PN EN 50131-10 : 2015 | Identical |
NBN EN 50131-10 : 2014 | Identical |
SN EN 50131-10 : 2014 | Identical |
BS EN 50131-10:2014 | Identical |
NEN EN 50131-10 : 2014 | Identical |
VDE 0830-2-10 : 2015 | Identical |
S.R. CLC/TS 50131-9:2014 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 9: ALARM VERIFICATION - METHODS AND PRINCIPLES |
CLC/TS 50131-9:2014 | Alarm systems - Intrusion and hold-up systems - Part 9: Alarm verification - Methods and principles |
PD CLC/TS 50131-9:2014 | Alarm systems. Intrusion and hold-up systems Alarm verification. Methods and principles |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
EN 50136-2:2013 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 50136-1:2012 | Alarm systems - Alarm transmission systems and equipment - Part 1: General requirements for alarm transmission systems |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 50131-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.