EN 50130-5:2011
Current
The latest, up-to-date edition.
ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
17-06-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental classes
5 Standard laboratory conditions
6 Tolerances
7 Information to be included in the relevant product standard
8 Dry heat (operational)
9 Dry heat (endurance)
10 Cold (operational)
11 Temperature change (operational)
12 Damp heat, steady state (operational)
13 Damp heat, steady state (endurance)
14 Damp heat, cyclic (operational)
15 Damp heat, cyclic (endurance)
16 Water ingress (operational)
17 Sulphur dioxide (SO[2]) (endurance)
18 Salt mist, cyclic (endurance)
19 Shock (operational)
20 Impact (operational)
21 Free fall (operational)
22 Vibration, sinusoidal (operational)
23 Vibration, sinusoidal (endurance)
24 Simulated solar radiation, temperature rise (operational)
25 Simulated solar radiation, surface degradation (endurance)
26 Dust tightness (endurance)
Bibliography
This European Standard specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: - intruder alarm systems; - hold-up alarm systems; - social alarm systems; - CCTV systems, for security applications; - access control systems, for security applications; - alarm transmission systems 1).
Committee |
TC 79
|
DevelopmentNote |
Supersedes PREN 50130-5. (08/2011)
|
DocumentType |
Test Method
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
I.S. EN 50130-5:2011 | Identical |
BS EN 50130-5:2011 | Identical |
CEI EN 50130-5 : 2012 | Identical |
NBN EN 50130-5 : 2011 | Identical |
NEN EN 50130-5 : 2011 | Identical |
PN EN 50130-5 : 2012 | Identical |
NF EN 50130-5 : 2011 | Identical |
UNE-EN 50130-5:2011 | Identical |
SN EN 50130-5 : 1999 | Identical |
VDE 0830-1-5 : 2012 | Identical |
DIN EN 50130-5 : 2012 | Identical |
BS EN 50131-2-7-3 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
CLC/TS 50131-2-5:2004 | Alarm systems - Intrusion systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors |
BS EN 50133-2-1:2000 | Alarm systems. Access control systems for use in security applications. General requirements for components |
04/30080013 DC : DRAFT FEB 2004 | EN 50131-1 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
CLC/TS 50131-2-6:2004 | Alarm systems - Intrusion systems - Part 2-6: Requirements for opening contacts (magnetic) |
16/30349685 DC : 0 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
07/30170080 DC : DRAFT AUG 2007 | PREN 50131-2-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
I.S. EN 50131-10:2014 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
BS EN 50131-2-2:2017 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Passive infrared detectors |
PD CLC/TS 50136-7:2017 | Alarm systems. Alarm transmission systems and equipment Application guidelines |
PD CLC/TS 50661-1:2017 | Alarm systems. External perimeter security systems System requirements |
DD CLC/TS 50131-2-3:2004 | Alarm systems. Intrusion systems Requirements for microwave detectors |
I.S. EN 50132-5-3:2012 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION |
CLC/TS 50131-2-3:2004 | Alarm systems - Intrusion systems - Part 2-3: Requirements for microwave detectors |
BS EN 50132-1:2010 | Alarm systems. CCTV surveillance systems for use in security applications System requirements |
I.S. EN 50131-2-2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
PD CLC/TS 50131-2-9:2016 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Active infrared beam detectors |
BS EN 50131-2-7-2 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
BS EN 50131-2-5:2008 | Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and ultrasonic detectors |
BS EN 50131-1 : 2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
BS EN 50131-8:2009 | Alarm systems. Intrusion and hold-up systems Security fog device/systems |
PD CLC/TS 50131-2-10:2014 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Lock state contacts (magnetic) |
PREN 50134-3 : DRAFT 2009 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER |
CLC/TS 50136-7:2017 | Alarm systems - Alarm transmission systems and equipment - Part 7: Application guidelines |
CLC/TS 50661-1:2017 | Alarm systems - External perimeter security systems - Part 1: System requirements |
S.R. CLC/TS 50131-2-7-3:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
PREN 50131-2-10 : DRAFT 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC) |
CEI EN 50131-2-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
I.S. EN 50131-2-7-1:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
OVE/ONORM EN 50131-2-4 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
CLC/TS 50131-3:2003 | Alarm systems - Intrusion systems - Part 3: Control and indicating equipment |
EN 50131-8:2009 | Alarm systems - Intrusion and hold-up systems - Part 8: Security fog device/systems |
EN 50132-5-3:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 5-3: Video transmission - Analogue and digital video transmission |
EN 50133-1 : 1996 AMD 1 2002 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) |
EN 50131-2-8:2016 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
OVE/ONORM EN 50131-2-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
PREN 54-13 : DRAFT 2014 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
08/30180887 DC : DRAFT MAY 2008 | BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
17/30353695 DC : 0 | BS EN 50131-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
99/703461 DC : DRAFT AUG 1999 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-2: REQUIREMENTS FOR PASSIVE INFRARED DETECTORS |
I.S. EN 50134-5:2004 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 5: INTERCONNECTIONS AND COMMUNICATIONS |
S.R. CLC/TS 50661-1:2017 | ALARM SYSTEMS - EXTERNAL PERIMETER SECURITY SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
02/708067 DC : DRAFT SEP 2002 | BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
BS EN 50134-2:2017 | Alarm systems. Social alarm systems Trigger devices |
BS EN 50136-3:2013 | Alarm systems. Alarm transmission systems and equipment Requirements for Receiving Centre Transceiver (RCT) |
BS EN 50131-2-4:2008 | Alarm systems. Intrusion and hold-up systems Requirements for combined passive infrared and microwave detectors |
PD CLC/TS 50131-11:2012 | Alarm systems. Intrusion and hold-up systems Hold-up devices |
CEI EN 50131-2-6 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
16/30299837 DC : 0 | BS EN 50131-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES |
16/30339543 DC : 0 | BS EN 62820-3-2 ED 1.0 - BUILDING INTERCOM SYSTEMS - PART 3-2: APPLICATION GUIDELINES - ADVANCED SECURITY BUILDING INTERCOM |
BS EN 50131-2-8:2016 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors |
CLC/TS 50136-4:2004 | Alarm systems - Alarm transmission systems and equipment - Part 4: Annunciation equipment used in alarm receiving centres |
07/19986727 DC : 0 | BS EN 50132-1 - ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
PREN 50131-6 : DRAFT 2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES |
UNE-EN 50136-2:2013 | Alarm systems - Alarm transmission systems and equipment - Part 2: Requirements for Supervised Premises Transceiver (SPT) |
BS EN 50131-3:2009 | Alarm systems. Intrusion and hold-up systems Control and indicating equipment |
07/30134620 DC : 0 | BS EN 50131-6 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES |
EN 50134-2:2017 | Alarm systems - Social alarm systems - Part 2: Trigger devices |
CEI EN 50131-1 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
BS EN 50132-5:2001 | Alarm systems. CCTV surveillance systems for use in security applications Video transmission |
VDE 0830-4-2 : 2000 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES |
CEI EN 50134-5 : 2006 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 5: INTERCONNECTIONS AND COMMUNICATIONS |
UNE-EN 50131-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 10: Application specific requirements for Supervised Premises Transceiver (SPT) |
I.S. EN 50136-3:2013 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 3: REQUIREMENTS FOR RECEIVING CENTRE TRANSCEIVER (RCT) |
I.S. EN 50131-2-4:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
I.S. CLC TS 50131-3:2003 | ALARM SYSTEMS - INTRUSION SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
I.S. EN 50131-8:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICE/SYSTEMS |
I.S. EN 50131-2-8:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
I.S. EN 50131-2-7-3:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
CEI EN 50131-2-4 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS |
I.S. TS 50136-4:2004 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 4: ANNUNCIATION EQUIPMENT USED IN ALARM RECEIVING CENTRES |
DIN EN 50134-2 : 2000 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES |
PREN 54-2 : DRAFT 2016 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
CLC/TS 50131-2-7-1:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic) |
CEI CLC/TS 50136-7 : 2004 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 7: APPLICATION GUIDELINES |
I.S. EN 50134-3:2012 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER |
S.R. CLC/TS 50131-2-7-2:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
I.S. EN 50131-1:2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-2-4:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-4: Requirements for combined passive infrared and microwave detectors |
11/30201835 DC : 0 | BS EN 50136-2 - ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
07/30162539 DC : 0 | BS EN 50131-2-2 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
17/30350085 DC : DRAFT SEP 2017 | BS EN 50131-8 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICES |
BS EN 50131-10:2014 | Alarm systems. Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT) |
09/30202602 DC : 0 | BS EN 50134-3 - ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 3: LOCAL UNIT AND CONTROLLER |
DD CLC/TS 50131-2-5:2004 | Alarm systems. Intrusion systems Requirements for combined passive infrared and ultrasonic detectors |
I.S. EN 50136-2:2013 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
DD CLC/TS 50131-2-7-2:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (passive) |
CEI EN 50136-3 : 2014 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 3: REQUIREMENTS FOR RECEIVING CENTRE TRANSCEIVER (RCT) |
TR 103 056 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS |
CEI EN 50132-5-3 : 2013 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION |
DD CLC/TS 50131-2-4:2004 | Alarm systems. Intrusion systems Requirements for combined passive infrared and microwave detectors |
PD CLC/TR 50531:2009 | Alarm systems. Terms and definitions |
CEI EN 50131-2-7-1 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
17/30358216 DC : DRAFT AUG 2017 | BS EN 50131-2-10 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC) |
CEI CLC/TS 50131-2-11 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR |
BS EN 50131-2-7-1 : 2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
I.S. EN 50132-1:2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
DIN EN 50133-2-1 : 2001 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: GENERAL REQUIREMENTS FOR COMPONENTS |
NF EN 50133-2-1 : 2001 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: GENERAL REQUIREMENTS FOR COMPONENTS |
EN 50134-5:2004 | Alarm systems - Social alarm systems - Part 5: Interconnections and communications |
S.R. CLC/TS 50131-2-9:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS |
S.R. CLC/TR 50531:2009 | ALARM SYSTEMS - TERMS AND DEFINITIONS |
I.S. EN 50131-3:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
S.R. CLC/TS 50131-2-11:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-11: INTRUSION DETECTORS - ALDDR |
CLC/TR 50531:2009 | Alarm systems - Terms and definitions |
PREN 50131-8 : DRAFT 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICES |
EN 50131-2-2:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-2: Intrusion detectors - Passive infrared detectors |
PREN 50131-1 : DRAFT 2004 | ALARM SYSTEMS - INTRUSION SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 54-13:2017 | Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components |
S.R. CLC/TS 50131-2-10:2014 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-10: INTRUSION DETECTORS - LOCK STATE CONTACTS (MAGNETIC) |
I.S. EN 54-13:2017 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
I.S. EN 50133-1:1997 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1 : SYSTEM REQUIREMENTS |
EN 50132-1 : 2010 COR 2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
BS EN 50131-2-3:2008 | Alarm systems. Intrusion and hold-up systems Requirements for microwave detectors |
CEI CLC/TS 50131-2-9 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-9: INTRUSION DETECTORS - ACTIVE INFRARED BEAM DETECTORS |
DD CLC/TS 50131-4:2006 | Alarm systems. Intrusion and hold-up systems Warning devices |
CEI EN 50131-2-7-2 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
EN 50136-3:2013 | Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT) |
CEI EN 50133-2-1 : 2001 | ALARM SYSTEMS ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: GENERAL REQUIREMENTS FOR COMPONENTS |
14/30290848 DC : 0 | BS EN 54-13 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
DD CLC/TS 50131-2-7-1:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (acoustic) |
CLC/TS 50131-2-11:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR |
BS EN 50131-2-6:2008 | Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic) |
I.S. EN 50133-2-1:2001 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - GENERAL REQUIREMENTS FOR COMPONENTS |
DD CLC/TS 50131-2-2:2004 | Alarm systems. Intrusion systems Requirements for passive infrared detectors |
CEI CLC/TS 50131-2-8 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
99/715383 DC : DRAFT OCT 1999 | BS EN 50131-4 - ALARM SYSTEMS - INTRUSION SYSTEMS - PART 4: WARNING DEVICES |
PD CLC/TS 50131-2-8:2012 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors |
11/30245742 DC : 0 | BS EN 50131-10 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
15/30290851 DC : 0 | BS EN 54-25 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
CLC/TS 50131-2-7-2:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive) |
UNE-EN 50131-2-7-1:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic) |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
BS EN 50133-1:1997 | Alarm systems. Access control systems for use in security applications System requirements |
CLC/TS 50131-2-8:2012 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
I.S. EN 50131-2-6:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-6: OPENING CONTACTS (MAGNETIC) |
UNE-EN 50131-2-8:2017 | Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors |
CEI EN 50136-2 : 2014 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
S.R. CLC/TS 50131-11:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
I.S. CLC TS 50131-4:2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
PREN 54-4 : DRAFT 2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT |
I.S. EN 50131-2-7-3:2012/A2:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
16/30312379 DC : 0 | BS EN 54-2 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
15/30290856 DC : 0 | BS EN 54-4 - FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4 : POWER SUPPLY EQUIPMENT |
I.S. EN 50131-4:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
I.S. EN 50131-2-5:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
DIN EN 54-13:2014-09 (Draft) | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
EN 50134-3:2012/AC:2015 | Alarm systems - Social alarm systems - Part 3: Local unit and controller |
UNE-EN 50131-2-7-2:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-2: Intrusion detectors - Glass break detectors (passive) |
UNE-EN 50131-2-7-3:2013 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
CLC/TS 50131-2-10:2014 | Alarm systems - Intrusion and hold-up systems - Part 2-10: Intrusion detectors - Lock state contacts (magnetic) |
PREN 50131-2-2 : DRAFT 2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
PREN 50131-10 : DRAFT 2011 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 10: APPLICATION SPECIFIC REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
DD CLC/TS 50131-2-7-3:2009 | Alarm systems. Intrusion and hold-up systems Intrusion detectors. Glass break detectors (active) |
DD CLC/TS 50131-2-6:2004 | Alarm systems. Intrusion systems Requirements for opening contacts (magnetic) |
I.S. EN 50131-2-3:2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
BS EN 50134-5:2004 | Alarm systems. Social alarm systems Interconnections and communications |
DD CLC/TS 50136-4:2004 | Alarm systems. Alarm transmission systems and equipment Annunciation equipment used in alarm receiving centres |
CEI EN 50131-2-7-3 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-3: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACTIVE) |
PREN 50132-5-3 : DRAFT 2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION |
10/30218198 DC : 0 | BS EN 50132-5-3:2010 - ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 5-3: VIDEO TRANSMISSION - ANALOGUE AND DIGITAL VIDEO TRANSMISSION |
CEI EN 50131-3 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 3: CONTROL AND INDICATING EQUIPMENT |
VDE 0830-8-2-1 : 2001 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 2-1: GENERAL REQUIREMENTS FOR COMPONENTS |
UNE-EN 50136-3:2014 | Alarm systems - Alarm transmission systems and equipment - Part 3: Requirements for Receiving Centre Transceiver (RCT) |
PREN 54-25 : DRAFT 2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
CEI CLC/TS 50131-11 : 2013 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
CEI EN 50131-2-2 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
DD CLC/TS 50131-3:2003 | Alarm systems. Intrusion systems Control and indicating equipment |
BS EN 50136-2:2013 | Alarm systems. Alarm transmission systems and equipment Requirements for Supervised Premises Transceiver (SPT) |
I.S. EN 50131-2-7-2:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
CEI EN 50131-2-5 : 2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
CEI EN 50131-2-8 : 1ED 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
07/30162638 DC : 0 | BS 50131-2-3 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-3: REQUIREMENTS FOR MICROWAVE DETECTORS |
PD CLC/TS 50131-2-11:2017 | PD CLC/TS 50131-2-11 Alarm systems - Intrusion and hold-up systems Part 2-11: Intrusion detectors - ALDDR |
BS EN 50132-5-3:2012 | Alarm systems. CCTV surveillance systems for use in security applications Video transmission. Analogue and digital video transmission |
BS EN 50134-3:2012 | Alarm systems. Social alarm systems Local unit and controller |
CEI EN 50131-8 : 2010 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 8: SECURITY FOG DEVICE/SYSTEMS |
07/30162640 DC : 0 | BS EN 50131-2-4 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRA-RED AND MICROWAVE DETECTORS |
UNE-EN 50131-4:2010 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
07/30162643 DC : DRAFT AUG 2007 | BS EN 50131-2-5 - ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
CLC/TS 50131-2-4:2004 | Alarm systems - Intrusion systems - Part 2-4: Requirements for combined passive infrared and microwave detectors |
S.R. CLC/TS 50131-2-7-1:2009 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
PREN 50131-4 : DRAFT 2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
UNE-EN 50131-1:2008 | Alarm systems - Intrusion and hold-up systems -- Part 1: System requirements |
OVE/ONORM EN 50131-2-2 : 2008 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS |
NF EN 50132-1 : 2010 | ALARM SYSTEMS - CCTV SURVEILLANCE SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
S.R. CLC/TS 50136-7:2017 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 7: APPLICATION GUIDELINES |
CEI EN 50134-2 : 2000 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES |
I.S. EN 50134-2:2017 | ALARM SYSTEMS - SOCIAL ALARM SYSTEMS - PART 2: TRIGGER DEVICES |
CLC/TS 50131-2-2:2004 | Alarm systems - Intrusion systems - Part 2-2: Requirements for passive infrared detectors |
CLC/TS 50131-2-7-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
S.R. CLC/TS 50131-2-8:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS |
BS EN 50131-4:2009 | Alarm systems. Intrusion and hold-up systems Warning devices |
PREN 50136-2 : DRAFT 2011 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
CEI CLC/TS 50136-4 : 2004 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 4: ANNUNCIATION EQUIPMENT USED IN ALARM RECEIVING CENTRES |
CEI EN 50131-4 : 2010 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 4: WARNING DEVICES |
I.S. EN 50131-6:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 6: POWER SUPPLIES |
BS EN 54-13:2017 | Fire detection and fire alarm systems Compatibility and connectability assessment of system components |
EN 50132-5:2001 | Alarm systems - CCTV surveillance systems for use in security applications - Part 5: Video transmission |
EN 50131-3:2009 | Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment |
CLC/TS 50131-11:2012 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 11: HOLD-UP DEVICES |
EN 50133-2-1:2000 | Alarm systems - Access control systems for use in security applications - Part 2-1: General requirements for components |
EN 50136-2:2013 | ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 2: REQUIREMENTS FOR SUPERVISED PREMISES TRANSCEIVER (SPT) |
EN 50131-2-7-3:2012/A2:2016 | Alarm systems - Intrusion and hold-up systems - Part 2-7-3: Intrusion detectors - Glass break detectors (active) |
EN 50131-2-6:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-6: Opening contacts (magnetic) |
EN 50131-2-7-2 : 2012 AMD 2 2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-2: INTRUSION DETECTORS - GLASS BREAK DETECTORS (PASSIVE) |
EN 50131-2-3:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-3: Requirements for microwave detectors |
EN 50131-2-5:2008 | Alarm systems - Intrusion and hold-up systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors |
EN 50131-2-7-1:2012/A2:2016 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-7-1: INTRUSION DETECTORS - GLASS BREAK DETECTORS (ACOUSTIC) |
CLC/TS 50131-4:2006 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
EN 50131-4:2009 | Alarm systems - Intrusion and hold-up systems - Part 4: Warning devices |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-18:2017 | Environmental testing - Part 2-18: Tests - Test R and guidance: Water |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-5:2011 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.