EN 181000:1994
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Generic Specification: Fibre optic branching devices
08-03-2017
15-07-1994
Foreword
SECTION ONE - GENERAL
1 General
1.1 Scope
1.2 Related documents
1.3 Definitions
SECTION TWO - REQUIREMENTS
2 Requirements
2.1 Classification
2.1.1 Type
2.1.2 Style
2.1.3 Variant
2.1.4 Climatic category
2.1.5 Assessment level
2.2 Minimum mandatory test sequence
2.3 Documentation
2.3.1 Symbols
2.3.2 Specification system
Blank detail specifications
Detail specifications
2.3.3 Drawings
Projection system
Dimensional system
Intermountability
2.3.4 Measurements
Measurement method
Reference components
Gauges
2.3.5 Test data sheets
2.3.6 Instructions for use
2.4 Design and construction
2.4.1 Materials
2.4.2 Workmanship
2.5 Quality
2.6 Performance requirements
2.7 Identification and marking
2.7.1 Variant identification number
2.7.2 Component marking
2.7.3 Package marking
2.8 Packaging
2.9 Ordering information
SECTION THREE - QUALITY ASSESSMENT PROCEDURES
3 Quality assessment procedures
3.1 Primary stage of manufacture
3.2 Structural similarity
3.3 Qualification approval procedures
3.3.1 Fixed sample procedure
3.3.2 Lot-by-lot and periodic procedure
3.3.3 Sample size
3.3.4 Preparation of specimens
3.3.5 Qualification testing
3.3.6 Qualification failures
3.3.7 Maintenance of qualification approval
3.3.8 Qualification report
3.4 Quality conformance inspection
3.4.1 Lot-by-lot inspection
Formation of inspection lots
Rejected lots
3.4.2 Periodic inspection
Sample size
Preparation of specimens
Periodic inspection
Periodic inspection failures
Periodic inspection report
3.5 Certified records of released lots
3.6 Delayed deliveries
3.7 Delivery release before completion of group B4
tests
3.8 Alternative test methods
3.9 Unchecked parameters
SECTION FOUR - MEASUREMENT AND ENVIRONMENTAL TEST
PROCEDURES
4 Measurement and environmental test procedures
4.1 Standard condition
4.2 Specimen
4.3 Cleaning of optical surfaces
4.4 Optical measurement conditions
4.5 Measurement procedures
4.5.1 Visual inspection
4.5.2 Dimensions and mass
4.5.3 Examination of product
4.5.4 Flammability
4.5.5 Insertion loss
4.5.6 Return loss
4.5.7 Wavelength dependence measurement
4.5.8 Polarization dependence of the transfer matrix
4.5.9 Change in transmitted optical power
4.5.10 Maximum input power
4.6 Environmental test procedures
4.6.1 Vibration
4.6.2 Effectiveness of fibre or ferrule retention
4.6.3 Static load
4.6.4 Pulling
4.6.5 Torsion
4.6.6 Strength of coupling mechanism
4.6.7 Bending moment
4.6.8 Bump
4.6.9 Shock
4.6.10 Crush resistance
4.6.11 Axial compression
4.6.12 Impact
4.6.13 Acceleration
4.6.14 Drop
4.6.15 Coupling proof torque
4.6.16 Mould growth
4.6.17 Cold
4.6.18 Dry heat
4.6.19 Damp heat (steady state)
4.6.20 Climatic sequence
4.6.21 Condensation
4.6.22 Change of temperature
4.6.23 Sealing (sealed branching devices)
4.6.24 Sealing (water immersion)
4.6.25 Sealing (hermetic)
4.6.26 Salt mist
4.6.27 Dust
4.6.28 Industrial atmosphere (sulphur dioxide)
4.6.29 Low air pressure
4.6.30 Solar radiation
4.6.31 Nuclear radiation
4.6.32 Mechanical endurance
4.6.33 High temperature endurance
4.6.34 Resistance to solvents and contaminating fluids
4.6.35 Cable Nutation
Annex A (Informative) Examples of fibre optic branching
device types
Annex B (Informative) Size measurements
Annex C (Informative) Summary of definitions from IEC Publications
This specifiation is applicable to fibre optic brancing devices. These have all of the following general features:- they are passive in that they contain no optoelectronic or other transducing elements;- they have three or more ports for the ingress and/or egress of optical power and share optical power among these ports in a predetermined fashion;- the ports are optical fibres or optical fibre connectors.In this generic specification, fibre optic branching devices are classified by wavelength dependance into two sub-families; wavelength selective devices and non-wavelength selective devices, each of which will be covered by a seperate blank detail specification.
Committee |
CLC/TC 86BXA
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
I.S. EN 181000:1994 | Identical |
NEN EN 181000 : 1998 | Identical |
BS EN 181000:1995 | Identical |
PN EN 181000 : 2002 | Identical |
DIN EN 181000:1995-02 | Identical |
UNE-EN 181000:1994 | Identical |
NBN EN 181000 : 2008 | Identical |
NF EN 181000 : 1995 | Identical |
BS EN 50083-6:1998 | Cabled distribution systems for television and sound signals Optical equipment |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
CECC 00109 : 1974 | CECC RULES OF PROCEDURE: RP 9: CERTIFIED TESTS RECORDS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
ISO 1101:2017 | Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
CECC 87000 : 1991 | OPTICAL FIBRE CABLES |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
CECC 00114-2 : 1994 | RULE OF PROCEDURE 14 - QUALITY ASSESSMENT PROCEDURES - PART 2: QUALIFICATION APPROVAL OF ELECTRONIC COMPONENTS |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-9:1975 | Environmental testing - Part 2: Tests. Guidance for solar radiation testing |
ISO 2015:1976 | Numbering of weeks |
ISO 370:1975 | Toleranced dimensions Conversion from inches into millimetres and vice versa |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
CECC 86000 : 1992 | CONNECTOR SETS FOR OPTICAL FIBRES AND CABLES - PART 1: REQUIREMENTS, TEST METHODS AND QUALIFICATION APPROVAL PROCEDURES (GENERIC SPECIFICATION) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
ISO 129:1985 | Technical drawings Dimensioning General principles, definitions, methods of execution and special indications |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
ISO/R 286:1962 | ISO system of limits and fits Part I : General, tolerances and deviations |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |