EN 1629:2011+A1:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
10-06-2021
23-12-2015
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Apparatus
5 Test specimen
6 Procedure
7 Expression of results
8 Test report
Annex A (normative) - Test equipment and impact points
Annex B (normative) - Test sequence for dynamic loading
test in resistance classes 1 to 3
Bibliography
This European Standard specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions.There are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. Due to the limitation of reproducing the fixing methods and building construction in a laboratory environment this aspect is not fully covered by the standard. This is particularly true with products built into a building. The performance of the fixed part of the product is evaluated using a standard sub frame. It is the manufacturer´s responsibility to ensure that guidance on the fixing of the product is contained in the mounting instructions and that this guidance is suitable for the burglar resistance class claimed for the product. As with the other referenced standards this specification uses a standard sub frame and the product is mounted according to the manufacturer´s instructions. The fixing method to be considered is detailed in Annex A of EN 1627:2011. This test method does not evaluate the performance of the fixing to the building.This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.
Committee |
CEN/TC 33
|
DevelopmentNote |
Supersedes ENV 1629. (05/2011) 2011 Edition Re-Issued in December 2015 & incorporates AMD 1 2015. (01/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNI EN 1629:2016 | Identical |
BS EN 1629 : 2011 | Identical |
SN EN 1629 : 2011 + A1 2015 | Identical |
NF EN 1629 : 2011 + A1 2016 | Identical |
PN EN 1629 : 2011 + A1 2016 | Identical |
UNI EN 1629 : 2011 | Identical |
NEN EN 1629 : 2011 + A1 2016 | Identical |
NBN EN 1629 : 2011 + A1 2016 | Identical |
NS EN 1629 : 2011 + A1 2015 | Identical |
I.S. EN 1629:2011 | Identical |
DIN EN 1629:2016-03 | Identical |
ONORM EN 1629 : 2016 | Identical |
UNE-EN 1629:2011+A1:2017 | Identical |
BS EN 1629:2011+A1:2015 | Identical |
UNE-EN 1629:2011 | Identical |
DIN EN 1629:2019-04 (Draft) | Identical |
14/30302455 DC : 0 | BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
PREN 13126-15 : DRAFT 2017 | QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS |
PREN 13126-8 : DRAFT 2016 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
17/30335089 DC : 0 | BS EN 13126-6 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY) |
PREN 13126-6 : DRAFT 2017 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY) |
18/30361306 DC : 0 | BS EN 13126-16 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS |
BS EN 13126-8:2017 | Building hardware. Hardware for windows and door height windows Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware |
BS EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Requirements and classification |
DIN EN 1628:2016-03 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading (includes Amendment A1:2015) |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
EN 1630:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
BS EN 1630 : 2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS |
PREN 13659 : DRAFT 2014 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
BS EN 16361 : 2013 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION |
I.S. EN 16361:2013 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION |
I.S. EN 13659:2015 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
PREN 13126-17 : DRAFT 2018 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS |
DIN EN 1627:2011-09 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
11/30253413 DC : 0 | BS EN 16361 - POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOOR SETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS |
EN 1628:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading |
DIN EN 1630:2016-03 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts (includes Amendment A1:2015) |
BS EN 1628 : 2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING |
I.S. EN 13126-8:2017 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT AND TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
PREN 13126-16 : DRAFT 2018 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS |
18/30361302 DC : 0 | BS EN 13126-17 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS |
16/30335086 DC : 0 | BS EN 13126-8 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
NF EN 1627 : 2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - REQUIREMENTS AND CLASSIFICATION |
UNI EN 1627 : 2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - REQUIREMENTS AND CLASSIFICATION |
EN 13126-8:2017 | Building hardware - Hardware for windows and door height windows - Part 8: Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware |
UNE-EN 13659:2016 | Shutters and external venetian blinds - Performance requirements including safety |
UNE-EN 1628:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading |
UNE-EN 1630:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
EN 13659:2015 | Shutters and external venetian blinds - Performance requirements including safety |
EN 16361:2013+A1:2016 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation |
I.S. EN 1627:2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - REQUIREMENTS AND CLASSIFICATION |
I.S. EN 1628:2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING |
UNI EN 16361 : 2013 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS |
18/30361299 DC : 0 | BS EN 13126-15 - QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS |
I.S. EN 1630:2011 | PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS |
DIN EN 13659:2015-07 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
BS EN 13659:2015 | Shutters and external venetian blinds. Performance requirements including safety |
UNE-EN 16361:2014 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics |
EN 1906:2012 | Building hardware - Lever handles and knob furniture - Requirements and test methods |
EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
EN 1303:2015 | Building hardware - Cylinders for locks - Requirements and test methods |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
EN 13241-1:2003+A1:2011 | Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics |
EN 1630:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 1628:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.