EN 1605:2013
Current
The latest, up-to-date edition.
Thermal insulating products for building applications - Determination of deformation under specified compressive load and temperature conditions
13-03-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Test specimens
7 Procedure
8 Calculation and expression of results
9 Accuracy of measurement
10 Test report
This European Standard specifies the equipment and procedures for determining the deformation occurring under specified conditions of compressive load, temperature and time. It is applicable to thermal insulating products.
Committee |
CEN/TC 88
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN 1605:2013-05 | Identical |
SN EN 1605 : 2013 | Identical |
GOST R EN 1605 : 2010 | Identical |
NS EN 1605 : 2013 | Identical |
UNE-EN 1605:2013 | Identical |
UNI EN 1605 : 2013 | Identical |
NF EN 1605 : 2013 | Identical |
NEN EN 1605 : 2013 | Identical |
BS EN 1605:2013 | Identical |
I.S. EN 1605:2013 | Identical |
PN EN 1605 : 2013 | Identical |
NBN EN 1605 : 2013 | Identical |
BS EN 16069 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
BS ISO 18097:2013 | Thermal insulating products for building equipment and industrial installations. Determination of maximum service temperature |
10/30213965 DC : 0 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 16025-1:2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
09/30209668 DC : 0 | BS EN 16025-1 - THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
DIN EN 16069:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
PREN 13169 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
12/30268937 DC : 0 | BS EN 16491 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
DIN EN 13169:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
BS EN 13163 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
BS EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of expanded polystyrene (EPS). Specification |
BS EN 13168 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS EN 13164 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 13168:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
I.S. EN 13165:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
DIN EN 14933:2007-12 | Thermal insulation and light weigth fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
EN 13163:2012+A2:2016 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
08/30169546 DC : DRAFT APR 2008 | BS EN 13167 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
07/30160790 DC : 0 | BS EN 15632-1 - DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
10/30213980 DC : 0 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
15/30315078 DC : DRAFT MAY 2015 | BS EN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 16025-1:2013-07 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
BS EN 16025-1:2013 | Thermal and/or sound insulating products in building construction. Bound EPS ballastings Requirements for factory premixed EPS dry plaster |
PREN 13165 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
BS ISO 18098:2013 | Thermal insulating products for building equipment and industrial installations. Determination of the apparent density of preformed pipe insulation |
PREN 13164 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
08/30169552 DC : DRAFT APR 2008 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED PERLITE (EPB) - SPECIFICATION |
I.S. EN 14315-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
BS EN 15632-1 : 2009 | DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
PREN 14933 : DRAFT 2004 | LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
DIN EN 13163:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
DIN EN 13170:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
DIN EN 13164:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 13165:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
DIN EN 13168:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS EN 13169 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 13163:2017-02 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13164:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 13163:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13167:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 13170:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
I.S. EN 13169:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
10/30213983 DC : 0 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
BS EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation |
08/30169549 DC : DRAFT APR 2008 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
10/30213977 DC : 0 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
DIN EN 14315-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
04/30113509 DC : DRAFT MAY 2004 | BS EN 14934 - THERMAL INSULATION OF ROAD AND RAILWAYS AND EMBANKMENT FILLING - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
DIN EN 14307:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
ISO 18098:2013 | Thermal insulating products for building equipment and industrial installations — Determination of the apparent density of preformed pipe insulation |
UNI EN 16025-1 : 2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
PREN 14307 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 13167:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 12089:2013 | Thermal insulating products for building applications. Determination of bending behaviour |
08/30169537 DC : DRAFT APR 2008 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
PREN 13170 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
UNI EN 14315-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
ISO 18099:2013 | Thermal insulating products for building equipment and industrial installations — Determination of the coefficient of thermal expansion |
PREN 13168 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS ISO 18099:2013 | Thermal insulating products for building equipment and industrial installations. Determination of the coefficient of thermal expansion |
08/30169540 DC : DRAFT APR 2008 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) PRODUCTS - SPECIFICATION |
08/30169534 DC : DRAFT APR 2008 | BS EN 13163 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
UNE-EN 15632-1:2010 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods |
UNE-EN 14307:2017 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
PREN 16491 : DRAFT 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
ISO 18097:2013 | Thermal insulating products for building equipment and industrial installations — Determination of maximum service temperature |
BS EN 13167 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 13165 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
UNE-EN 13167:2013 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
UNE-EN 13164:2013 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
UNE-EN 13169:2013 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
UNE-EN 13165:2013 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
UNE-EN 13163:2013 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
UNE-EN 16069:2013 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
UNE-EN 13170:2013 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
UNE-EN 13168:2013 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
UNE-EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
EN 13168:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
EN 13164:2012+A1:2015 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 16069:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
EN 15632-1:2009+A1:2014 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
EN 16025-1:2013 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
08/30194543 DC : 0 | BS ISO 2219 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY-MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
10/30213968 DC : 0 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
05/30136538 DC : 0 | PREN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
08/30169556 DC : DRAFT APR 2008 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
UNE-EN 16025-1:2016 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
04/30113504 DC : DRAFT MAY 2004 | BS EN 14933 - LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
UNE-EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane foam (PUR) products. Part 1: Specification for the rigid foam spray system before installation |
DIN EN 15632-1:2015-03 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods (includes Amendment A1:2014) |
I.S. EN 16069:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
17/30360238 DC : 0 | BS EN 17140 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE VACUUM INSULATION PANELS (VIP) - SPECIFICATION |
I.S. EN 15632-1:2009 | DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
BS EN 13170 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
BS EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of extruded polystyrene foam (XPS). Specification |
EN 13170:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
EN 13169:2012+A1:2015 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
EN 13167:2012+A1:2015 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
DIN EN 14934:2007-12 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
EN 13165:2012+A2:2016 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
EN 12085:2013 | Thermal insulating products for building applications - Determination of linear dimensions of test specimens |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.