EN 14710-1:2005+A2:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Fire-fighting pumps - Fire-fighting centrifugal pumps without primer - Part 1: Classification, general and safety requirements
28-12-2009
17-12-2008
Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 List of significant hazards
5 Safety requirements and/or protective measures
6 General and performance requirements
7 Verification of the safety requirements and/or
protective measures
8 Verification of the general and performance requirements
9 Classification and brief designation
10 Designation
11 Information for use
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 98/37/EC
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 2006/42/EC
Bibliography
This document applies to centrifugal pumps without priming devices for fire-fighting use designed as -floating pumps (FPN F),-submersible pumps (FPN S) or -boosted pumps (FPN B). Fire-fighting centrifugal pumps without primer are defined as terminated by their inlet and outlet connections as well as by their shaft ends.This document applies for fire-fighting centrifugal pumps without priming devices for use under ambient temperatures between -15 °C and 40 °C.NOTE 1For special conditions, -30 C; see 6.11.This document does not apply to fire-fighting centrifugal pumps without primer of which the only power source is directly applied manual effort.This document does not apply to fire-fighting centrifugal pumps without primer, intended to be used as interchangeable equipment (i.e. combined by the user with another machine or vehicle acting as a driver).This document does not apply to fire-fighting centrifugal pumps without primer with a nominal delivery pressure pN above 15 bar.NOTE 2High pressure pumps with primer are dealt with in EN 1028-1 and EN 1028-2.This document specifies the classification and general requirements for fire-fighting centrifugal pumps without priming devices with a nominal delivery rate of up to 10 000 l/min.This document deals with significant hazards listed in Clause 4, hazardous situations and events during the commissioning, operation and maintenance of fire-fighting centrifugal pumps without priming devices, used as intended and under the conditions foreseen by the manufacturer.This document does not deal with the detailed verification of general and safety requirements and/or protective measures. These are covered in EN 14710-2 "Verification of general and safety requirements".This document does not deal with noise.This document does not deal with the technical safety requirements for the design or manufacture of drivers or of additional equipment intended to be fitted to inlet and outlet connections.
Committee |
CEN/TC 192
|
DevelopmentNote |
2005 Edition Re-Issued in December 2008 & incorporates AMD 2 2008. (02/2009)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DIN EN 14710-1:2009-06 | Identical |
UNE-EN 14710-1:2006 | Identical |
I.S. EN 14710-1:2005 | Identical |
NEN EN 14710-1 : 2005 + A2 2009 | Identical |
NBN EN 14710-1 : 2005 + A2 2009 | Identical |
SN EN 14710-1 : 2005 + A2 2009 | Identical |
UNI EN 14710-1 : 2009 | Identical |
NS EN 14710-1 : 2005 + A2 2008 | Identical |
BS EN 14710-1 : 2005 | Identical |
PN EN 14710-1 : 2005 + A2 2010 | Identical |
NF EN 14710-1 : 2005 + A2 2009 | Identical |
UNE-EN 14710-1:2006+A2:2009 | Identical |
BS EN 14710-1:2005+A2:2008 | Identical |
S.R. CEN TR 16099:2010 | FIRE SERVICE EQUIPMENT - SUMMARY OF WATER PRESSURES SPECIFIED IN PUBLISHED CEN/TC 192 STANDARDS |
PD CEN/TR 16099:2010 | Fire service equipment. Summary of water pressures specified in published CEN/TC 192 standards |
DIN EN 14710-2:2009-06 | Fire-fighting pumps - Fire-fighting centrifugal pumps without primer - Part 2: Verification of general and safety requirements (includes Amendment A2:2008) |
CEN/TR 16099:2010 | Fire service equipment - Summary of water pressures specified in published CEN/TC 192 standards |
UNE-EN 16327:2015 | Fire-fighting - Positive-pressure proportioning systems (PPPS) and compressed-air foam systems (CAFS) |
I.S. EN 1846-3:2013 | FIREFIGHTING AND RESCUE SERVICE VEHICLES - PART 3: PERMANENTLY INSTALLED EQUIPMENT - SAFETY AND PERFORMANCE |
I.S. EN 14710-2:2005 | FIRE-FIGHTING PUMPS - FIRE-FIGHTING CENTRIFUGAL PUMPS WITHOUT PRIMER - PART 2: VERIFICATION OF GENERAL AND SAFETY REQUIREMENTS |
UNI EN 16327 : 2014 | FIRE-FIGHTING - POSITIVE-PRESSURE PROPORTIONING SYSTEMS (PPPS) AND COMPRESSED-AIR FOAM SYSTEMS (CAFS) |
EN 1846-3:2013 | Firefighting and rescue service vehicles - Part 3: Permanently installed equipment - Safety and performance |
UNI EN 1846-3 : 2013 | FIREFIGHTING AND RESCUE SERVICE VEHICLES - PART 3: PERMANENTLY INSTALLED EQUIPMENT - SAFETY AND PERFORMANCE |
UNI EN 14710-2 : 2009 | FIRE-FIGHTING PUMPS - FIRE-FIGHTING CENTRIFUGAL PUMPS WITHOUT PRIMER - PART 2: VERIFICATION OF GENERAL AND SAFETY REQUIREMENTS |
BS EN 16327:2014 | Fire-fighting. Positive-pressure proportioning systems (PPPS) and compressed-air foam systems (CAFS) |
BS EN 1846-3:2013 | Firefighting and rescue service vehicles Permanently installed equipment. Safety and performance |
BS EN 14710-2 : 2005 | FIRE-FIGHTING PUMPS - FIRE-FIGHTING CENTRIFUGAL PUMPS WITHOUT PRIMER - PART 2: VERIFICATION OF GENERAL AND SAFETY REQUIREMENTS |
EN 14710-2:2005+A2:2008 | Fire-fighting pumps - Fire-fighting centrifugal pumps without primer - Part 2: Verification of general and safety requirements |
EN 16327:2014 | Fire-fighting - Positive-pressure proportioning systems (PPPS) and compressed-air foam systems (CAFS) |
DIN EN 16327:2014-07 | FIRE-FIGHTING - POSITIVE-PRESSURE PROPORTIONING SYSTEMS (PPPS) AND COMPRESSED-AIR FOAM SYSTEMS (CAFS) |
I.S. EN 16327:2014 | FIRE-FIGHTING - POSITIVE-PRESSURE PROPORTIONING SYSTEMS (PPPS) AND COMPRESSED-AIR FOAM SYSTEMS (CAFS) |
UNE-EN 1846-3:2015 | Firefighting and rescue service vehicles - Part 3: Permanently installed equipment - Safety and performance |
DIN EN 1846-3:2013-11 | FIREFIGHTING AND RESCUE SERVICE VEHICLES - PART 3: PERMANENTLY INSTALLED EQUIPMENT - SAFETY AND PERFORMANCE |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
EN 14466:2005+A1:2008 | Fire-fighting pumps - Portable pumps - Safety and performance requirements, tests |
ISO 7010:2011 | Graphical symbols Safety colours and safety signs Registered safety signs |
EN 894-3:2000+A1:2008 | Safety of machinery - Ergonomics requirements for the design of displays and control actuators - Part 3: Control actuators |
ISO 9905:1994 | Technical specifications for centrifugal pumps — Class I |
EN 547-2:1996+A1:2008 | Safety of machinery - Human body measurements - Part 2: Principles for determining the dimensions required for access openings |
IEC 61310-2:2007 | Safety of machinery - Indication, marking and actuation - Part 2: Requirements for marking |
EN 894-2:1997+A1:2008 | Safety of machinery - Ergonomics requirements for the design of displays and control actuators - Part 2: Displays |
ISO 5199:2002 | Technical specifications for centrifugal pumps — Class II |
EN 61310-2:2008 | Safety of machinery - Indication, marking and actuation - Part 2: Requirements for marking |
EN 1028-2:2002+A1:2008 | Fire-fighting pumps - Fire-fighting centrifugal pumps with primer - Part 2: Verification of general and safety requirements |
ISO 13732-1:2006 | Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces |
ISO 9908:1993 | Technical specifications for centrifugal pumps — Class III |
EN ISO 14121-1:2007 | Safety of machinery - Risk assessment - Part 1: Principles (ISO 14121-1:2007) |
EN 349:1993+A1:2008 | Safety of machinery - Minimum gaps to avoid crushing of parts of the human body |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
EN ISO 5199:2002 | Technical specifications for centrifugal pumps - Class II (ISO 5199:2002) |
EN ISO 13857:2008 | Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs (ISO 13857:2008) |
ISO 14121-1:2007 | Safety of machinery Risk assessment Part 1: Principles |
EN 14710-2:2005+A2:2008 | Fire-fighting pumps - Fire-fighting centrifugal pumps without primer - Part 2: Verification of general and safety requirements |
EN ISO 13732-1:2008 | Ergonomics of the thermal environment - Methods for the assessment of human responses to contact with surfaces - Part 1: Hot surfaces (ISO 13732-1:2006) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 953:1997+A1:2009 | Safety of machinery - Guards - General requirements for the design and construction of fixed and movable guards |
EN 842:1996+A1:2008 | Safety of machinery - Visual danger signals - General requirements, design and testing |
EN 62079:2001 | Preparation of instructions - Structuring, content and presentation |
EN 547-3:1996+A1:2008 | Safety of machinery - Human body measurements - Part 3: Anthropometric data |
ISO 12100-2:2003 | Safety of machinery Basic concepts, general principles for design Part 2: Technical principles |
IEC 62079:2001 | Preparation of instructions - Structuring, content and presentation |
ISO 13857:2008 | Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs |
EN 1028-1:2002+A1:2008 | Fire-fighting pumps - Fire-fighting centrifugal pumps with primer - Part 1: Classification - General and safety requirements |
ISO 12100-1:2003 | Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology |
EN 1846-1:2011 | Firefighting and rescue service vehicles - Part 1: Nomenclature and designation |
IEC 61310-1:2007 | Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
1998/37/EC : 1998 | DIRECTIVE 98/37/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 22 JUNE 1998 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO MACHINERY |
EN 61310-1:2008 | Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
EN 60204-1 : 2006 COR 2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
EN 894-1:1997+A1:2008 | Safety of machinery - Ergonomics requirements for the design of displays and control actuators - Part 1: General principles for human interactions with displays and control actuators |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.