EN 14662-3:2015

Current

Current

The latest, up-to-date edition.

Ambient air - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography

Published date

18-11-2015

Sorry this product is not available in your region.

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Principle
6 Sampling equipment
7 Analyser equipment
8 Type approval of benzene analysers
9 Field operation and ongoing quality control
10 Expression of results
11 Test reports and documentation
Annex A (normative) - Test of lack of fit
Annex B (informative) - Sampling equipment
Annex C (informative) - Components and applications
        of benzene analysers
Annex D (informative) - Manifold testing equipment
Annex E (normative) - Type approval
Annex F (informative) - Calculation of uncertainty in field
        operation at the annual limit value
Bibliography

This European Standard specifies a semi-continuous measurement method for the determination of the concentration of benzene present in ambient air based on automated sampling and analysis by gas chromatography. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate automated gas chromatograph (GC) by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.The method is applicable to the determination of the mass con¬centration of benzene present in ambient air in the range up to 50 µg/m3 benzene. This concentration range represents the certification range for the type approval test.Other ranges may be used depending on the levels present in ambient air. NOTE 1When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.The method covers the determination of ambient air concentrations of benzene in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).NOTE 250 µg/m3 of benzene corresponds to 15,4 nmol/mol of benzene.This European Standard contains information for different groups of users.Clauses 5 to 7 and Annexes C and D contain general information about the principles of benzene measurement by automated gas chromatography and sampling equipment.Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of benzene analysers. These sections contain information about:-type-approval test conditions, test procedures and test requirements;-analyser performance requirements;-evaluation of the type-approval test results;-evaluation of the uncertainty of the measurement results of the benzene analyser based on the type-approval test results.Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of benzene in ambient air. These sections contain information about:-initial installation of the analyser in the monitoring network and acceptance testing;-ongoing quality assurance/quality control;-calculation and reporting of measurement results;-evaluation of the uncertainty of measurement results under practical monitoring conditions.

Committee
CEN/TC 264
DevelopmentNote
Supersedes PREN 14662-3. (11/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

UNI EN 15267-1 : 2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
ONORM EN 15267-1 : 2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
VDI 2100 Blatt 5:2007-02 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Determination of volatile organic compounds, especially ozone precursors
I.S. EN 15267-1:2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
BS EN 15267-1:2009 Air quality. Certification of automated measuring systems General principles
DIN EN 15267-1:2009-07 Air quality - Certification of automated measuring systems - Part 1: General principles
NS-EN 14662-1:2023 Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN ISO 6145-4:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 4: Continuous syringe injection method (ISO 6145-4:2004)
ISO 6144:2003 Gas analysis — Preparation of calibration gas mixtures — Static volumetric method
EN ISO 6145-8:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 8: Diffusion method (ISO 6145-8:2005)
EN ISO 6142:2006 Gas analysis - Preparation of calibration gas mixtures - Gravimetric method (ISO 6142:2001)
ISO 6145-7:2009 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 6145-7:2010 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 7: Thermal mass-flow controllers (ISO 6145-7:2009)
EN ISO 6143:2006 Gas analysis - Comparison methods for determining and checking the composition of calibration gas mixtures (ISO 6143:2001)
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
EN ISO 6145-9:2010 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 9: Saturation method (ISO 6145-9:2009)
EN ISO 6145-10:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
ISO 6143:2001 Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
ISO 6145-10:2002 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method
ISO 9001:2015 Quality management systems — Requirements
ISO 6145-4:2004 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method
EN ISO 6145-6:2017 Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 6: Critical flow orifices (ISO 6145-6:2017)
ISO 6145-9:2009 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 9: Saturation method
ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
ISO 6145-8:2005 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 8: Diffusion method
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
EN ISO 6144:2006 Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.