EN 140101:2008
Current
The latest, up-to-date edition.
Blank Detail Specification: Fixed low power film resistors
21-03-2008
Introduction
1 Characteristics and ratings
1.1 Dimensions and ratings
1.2 Derating curve
1.3 Resistance range and tolerance on rated
resistance
1.4 Variation of resistance with temperature
and temperature rise
1.5 Climatic categories
1.6 Limits for change of resistance at tests
1.7 Non-linear properties
1.8 Tests related to soldering
1.9 Marking, packaging and ordering designation
1.10 Additional information (not for inspection
purpose)
2 Quality assessment procedures
2.1 General
2.2 Qualification Approval
2.3 Quality Conformance Inspection
Annex A (normative) - Fixed sample size Qualification
Approval and Quality Conformance
Inspection test schedule for fixed
low power film resistors
Annex B (informative) - Letter symbols and abbreviations
Bibliography
A Blank Detail Specification is a supplementary document to the sectional specification and containsrequirements for style and layout and minimum content of detail specifications. Detail specifications notcomplying with these requirements shall not be considered as being in accordance with European standardsnor shall they be so described.In the preparation of the detail specification the content of EN 140100:2008, 1.2 shall be taken into account.The detail specification should be written by using the preferred values given in EN 140100.The detail specification should contain a table of contents prior the first page of the actual specification.For the use of SI units refer to ISO 1000, for the use of letter symbols to be used in electrical technologyrefer to EN 60027-1.
Committee |
CLC/TC 40XB
|
DevelopmentNote |
Supersedes CECC 40101 (07/2005)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NBN EN 140101 : 2008 | Identical |
UNE-EN 140101:2008 | Identical |
SN EN 140101 : 2008 | Identical |
NF EN 140101 : 2008 | Identical |
BS EN 140101:2008 | Identical |
I.S. EN 140101:2008 | Identical |
NEN EN 140101 : 2008 | Identical |
CEI EN 140101 : 2009 | Identical |
PN EN 140101 : 2008 | Identical |
DIN EN 140101:2008-08 | Identical |
PNE-prEN 140101 | Identical |
I.S. EN 140101-806:2009 | DETAIL SPECIFICATION: FIXED LOW POWER FILM RESISTORS - METAL FILM RESISTORS ON HIGH GRADE CERAMIC, CONFORMAL COATED OR MOLDED, AXIAL OR PREFORMED LEADS |
02/203178 DC : 0 | PREN 140101-806 - DETAIL SPECIFICATION - FIXED LOW POWER NON-WIRE WOUND RESISTORS - METAL FILM RESISTORS ON HIGH GRADE CERAMIC, CONFORMAL COATED OR MOLDED, AXIAL OR PREFORMED LEADS - ASSESSMENT LEVEL Z - VERSION A: WITH 100-%-TEST - VERSION E: WITH FAILURE RATE LEVEL AND 100-%-TEST - STABILITY CLASSES 0,05; 0,1; 0,25; 0,5; 1; 2 |
BS EN 140101-806 : 2008 | DETAIL SPECIFICATION: FIXED LOW POWER FILM RESISTORS - METAL FILM RESISTORS ON HIGH GRADE CERAMIC, CONFORMAL COATED OR MOLDED, AXIAL OR PREFORMED LEADS |
EN 140101-806 : 2008 COR 2014 | DETAIL SPECIFICATION: FIXED LOW POWER FILM RESISTORS - METAL FILM RESISTORS ON HIGH GRADE CERAMIC, CONFORMAL COATED OR MOLDED, AXIAL OR PREFORMED LEADS |
IEC 61193-2:2007 | Quality assessment systems - Part 2: Selection and use of sampling plans for inspection of electronic components and packages |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
CECC 240001 : 1996 | FIXED LOW POWER FILM RESISTORS (LEADED/UNLEADED) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IECQ 001002-3:2005 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ) - RULES OF PROCEDURE - PART 3: APPROVAL PROCEDURES |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
HD 349 : 200S1 | PREFERRED DIAMETERS OF WIRE TERMINATIONS OF CAPACITORS AND RESISTORS |
EN 61760-1:2006 | SURFACE MOUNTING TECHNOLOGY - PART 1: STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING COMPONENTS (SMDS) |
IEC 61760-1:2006 | Surface mounting technology - Part 1: Standard method for the specification of surface mounting components (SMDs) |
EN 60027-1:2006/A2:2007 | LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY - PART 1: GENERAL |
EN 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 61193-2 : 2007 | QUALITY ASSESSMENT SYSTEMS - PART 2: SELECTION AND USE OF SAMPLING PLANS FOR INSPECTION OF ELECTRONIC COMPONENTS AND PACKAGES |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60115-1:2011/A11:2015 | FIXED RESISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
IEC TR 60440:1973 | Method of measurement of non-linearity in resistors |
EN 61340-3-1:2007 | Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
EN 140100:2008 | Sectional Specification: Fixed low power film resistors |
IEC 61340-3-1:2006 | Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms |
IEC 60301:2012 | Preferred diameters of wire terminations of capacitors and resistors |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60063:2015 | Preferred number series for resistors and capacitors |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60286-1:2017 | Packaging of components for automatic handling - Part 1: Tape packaging of components with axial leads on continuous tapes |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60115-1:2008 | Fixed resistors for use in electronic equipment - Part 1: Generic specification |
IEC 60195:2016 | Method of measurement of current noise generated in fixed resistors |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.