• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 1366-9:2008

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Fire resistance tests for service installations - Part 9: Single compartment smoke extraction ducts

Withdrawn date

30-09-2008

Published date

19-03-2008

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
   4.1 General
   4.2 Furnace
   4.3 Perforated plate
   4.4 Inlet nozzles (fire test)
   4.5 Ambient leakage measuring device
   4.6 Pressure sensors for differential pressure control
   4.7 Welded connecting tube
   4.8 Extract fan connecting duct
   4.9 Extraction fan
   4.10 Thermocouples
   4.11 Oxygen measuring equipment
   4.12 Restraint equipment
   4.13 Observation window
5 Test conditions
   5.1 Differential pressure conditions
   5.2 Heating conditions
6 Test specimen
   6.1 Size
        6.1.1 Length
        6.1.2 Cross-section
   6.2 Number
   6.3 Design
7 Installation of test specimen
   7.1 General
   7.2 Standard supporting construction
   7.3 Duct arrangement
   7.4 Restraint of ducts
   7.5 Perforated plate
8 Conditioning
   8.1 General
9 Application of instrumentation
   9.1 Thermocouples
        9.1.1 Furnace thermocouples (plate thermometers)
        9.1.2 Gas temperature within flow nozzles
   9.2 Pressure
   9.3 Oxygen measurements
   9.4 Observations of reduction of cross-section
10 Test procedure
   10.1 Pre-test calibration
        10.1.1 Oxygen-measuring instrument
        10.1.2 Perforated plate
   10.2 Leakage measurement at ambient temperature
   10.3 Fire test
        10.3.1 Extraction fan
        10.3.2 Ignition of furnace
        10.3.3 Furnace conditions
        10.3.4 Temperatures and pressures
        10.3.5 Oxygen measurements
        10.3.6 General observations
        10.3.7 Reduction of cross-section
        10.3.8 Leakage calculations
        10.3.9 Termination of test
11 Performance criteria
   11.1 General requirements
   11.2 Criteria at ambient temperature
   11.3 Criteria under fire conditions
        11.3.1 General
        11.3.2 Leakage
        11.3.3 Reduction in cross-section
        11.3.4 Mechanical stability
12 Test report
13 Direct field of application of test results
   13.1 General
   13.2 Duct sizes
   13.3 Hangers
   13.4 Pressure difference
   13.5 Number of sides of duct
Annex A (informative) - Measurement of volume/mass flow
      A.1 Hints on measuring volume flow or mass flow
          with differential pressure devices
      A.2 Density
      A.3 Absolute Pressure (barometric pressure)
      A.4 Viscosity
      A.5 Characteristic data of the inlet nozzles
          according to Figure 10
Annex B (informative) - Measurement of oxygen content
Annex C (informative) - The usage of correction factors for
                        the consideration of different parameters
Bibliography

This part of EN 1366 specifies a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only. In such applications, the smoke extraction system is only intended to function up to flashover (typically 600 °C). This method of test is only suitable for ducts constructed from non-combustible materials (euro class A1 and A2-s1, d0).It is applicable only to four sided and circular ducts. One, two and three sided ducts are not covered.This test has been designed to cover horizontal smoke extraction ducts intended for single compartment applications only.This test method of part 9 is applicable only to smoke extraction ducts that do not pass through into other fire compartments. It represents fire exposure of a developing fire (pre-flashover). For smoke extraction ducts that pass through into other compartments, the method of test described in EN 1366-8 should be used.The smoke extraction duct is part of the smoke extraction system which also includes smoke control dampers and smoke extract fans.The method described in this test standard is complex and requires sophisticated instrumentation. It is not recommended therefore to try to test multiple assemblies in this test.

Committee
CEN/TC 127
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
PN EN 1366-9 : 2009 Identical
UNI EN 1366-9 : 2008 Identical
NS EN 1366-9 : 1ED 2008 Identical
UNE-EN 1366-9:2009 Identical
DIN EN 1366-9:2008-08 Identical
NF EN 1366-9 : 2009 Identical
SN EN 1366-9 : 2008 Identical
NEN EN 1366-9 : 2008 Identical
BS EN 1366-9:2008 Identical
I.S. EN 1366-9:2008 Identical
NBN EN 1366-9 : 2008 Identical
DS EN 1366-9 : 2008 Identical

BS EN 1366-10 : 2011 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 10: SMOKE CONTROL DAMPERS
I.S. EN 1366-10:2011 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 10: SMOKE CONTROL DAMPERS
NF EN 12101-7 : 2011 SMOKE AND HEAT CONTROL SYSTEMS - PART 7: SMOKE DUCT SECTIONS
EN 12101-7:2011 Smoke and heat control systems - Part 7: Smoke duct sections
UNI EN 15423 : 2008 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
BS EN 12101-7:2011 Smoke and heat control systems Smoke duct sections
BS EN 15423:2008 Ventilation for buildings. Fire precaution for air distribution systems in buildings
15/30300929 DC : 0 BS EN 13501-4 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 4: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS ON COMPONENTS OF SMOKE CONTROL SYSTEMS
S.R. CEN/TR 12101-4:2009 SMOKE AND HEAT CONTROL SYSTEMS - PART 4: INSTALLED SHEVS SYSTEMS FOR SMOKE AND HEAT VENTILATION
I.S. EN 13501-4:2016 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 4: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS ON COMPONENTS OF SMOKE CONTROL SYSTEMS
DIN EN 1366-10:2011-07 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 10: SMOKE CONTROL DAMPERS
14/30291693 DC : 0 BS ISO 21927-7 - SMOKE AND HEAT CONTROL SYSTEMS - PART 7: SMOKE DUCTS SECTIONS
UNE-EN 12101-7:2013 Smoke and heat control systems - Part 7: Smoke duct sections
14/30291624 DC : 0 BS ISO 21927-8 - SMOKE AND HEAT CONTROL SYSTEMS - PART 8: SMOKE CONTROL DAMPERS
BS EN 12101-8:2011 Smoke and heat control systems Smoke control dampers
BS EN 13501-4 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 4: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS ON COMPONENTS OF SMOKE CONTROL SYSTEMS
UNE-EN 1366-10:2016 Fire resistance tests for service installations - Part 10: Smoke control dampers
04/30124515 DC : 0 EN 1366-10 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 10: SMOKE CONTROL DAMPERS
BS ISO 21927-7:2017 Smoke and heat control systems Smoke ducts sections
CEN/TR 12101-4:2009 Smoke and heat control systems - Part 4: Installed SHEVS systems for smoke and heat ventilation
DIN EN 12101-8:2011-08 Smoke and heat control systems - Part 8: Smoke control dampers
UNI EN 12101-8 : 2011 SMOKE AND HEAT CONTROL SYSTEMS - PART 8: SMOKE CONTROL DAMPERS
I.S. EN 12101-7:2011 SMOKE AND HEAT CONTROL SYSTEMS - PART 7: SMOKE DUCT SECTIONS
PREN 13501-4 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 4: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS ON COMPONENTS OF SMOKE CONTROL SYSTEMS
ISO 21927-8:2017 Smoke and heat control systems — Part 8: Smoke control dampers
EN 15423:2008 Ventilation for buildings - Fire precautions for air distribution systems in buildings
EN 1366-10:2011+A1:2017 Fire resistance tests for service installations - Part 10: Smoke control dampers
I.S. EN 12101-8:2011 SMOKE AND HEAT CONTROL SYSTEMS - PART 8: SMOKE CONTROL DAMPERS
01/541305 DC : DRAFT OCT 2001 BS EN 12101-6 - SMOKE AND HEAT CONTROL SYSTEMS - PART 6: PRESSURE DIFFERENTIAL SYSTEMS - KITS
UNE-EN 12101-8:2015 Smoke and heat control systems - Part 8: Smoke control dampers
DIN EN 12101-7:2011-08 Smoke and heat control systems - Part 7: Smoke duct sections
DIN EN 15423:2008-09 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
UNI EN 1366-10 : 2011 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 10: SMOKE CONTROL DAMPERS
BS ISO 21927-8:2017 Smoke and heat control systems Smoke control dampers
UNI EN 12101-7 : 2011 SMOKE AND HEAT CONTROL SYSTEMS - PART 7: SMOKE DUCT SECTIONS
I.S. EN 15423:2008 VENTILATION FOR BUILDINGS - FIRE PRECAUTIONS FOR AIR DISTRIBUTION SYSTEMS IN BUILDINGS
ISO 21927-7:2017 Smoke and heat control systems — Part 7: Smoke ducts sections
EN 13501-4:2016 Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems
EN 12101-8:2011 Smoke and heat control systems - Part 8: Smoke control dampers

EN 1507:2006 Ventilation for buildings - Sheet metal air ducts with rectangular section - Requirements for strength and leakage
ISO 10294-3:1999 Fire resistance tests Fire dampers for air distribution systems Part 3: Guidance on the test method
ISO 13943:2017 Fire safety — Vocabulary
EN 1366-1:2014 Fire resistance tests for service installations - Part 1: Ventilation ducts
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
EN 1366-8:2004 Fire resistance tests for service installations - Part 8: Smoke extraction ducts
EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1751:2014 Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves
ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.