Paper and board - Paper and board intended to come into contact with foodstuffs - Determination of mercury in an aqueous extract
24-08-2005
Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents
4.1 General
4.2 Nitric acid (HNO[3]), 65% (d = 1.42)
4.2.1 Nitric acid (4.2), diluted 1:1 (V/V) with water
4.2.2 Nitric acid (4.2), diluted to 1.5% (V/V) with water
4.3 Potassium permanganate (KMno[4]), 5% aqueous solution (m/V)
4.4 Mercury, stock solution, 1000 mg/l
Sulphuric acid (H[2]SO[4]), (d = 1,84)
4.6 Potassium dichromate (K[2]Cr[2]O[7]), 50 g/l in
sulphuric acid solution
4.7 Hydroxylammonium chloride (HONH[3]Cl), 20 g/l aqueous
solution
4.8 Reducing solutions
4.8.1 Tin (2) chloride (SnCl[2] . 2H[2]O), 50 g/l
in 10% hydroxhloric acid (4.9.1)
4.8.2 Sodium tetrahydroborate (NaBH[4]), 0.2 g/l in 0.05%
sodium hydroxide solution (4.10)
4.9 Hydrochloric acid (HCl), 36% (d = 1.19)
4.9.1 Hydrochloric acid (4.9) (HCl), diluted 10% (V/V)
4.10 Sodium hydroxide (NaOH), 0.05% aqueous solution (m/V)
5 Apparatus
5.1 General
5.2 General laboratory equipment
5.3 Volumetric flasks, 100 ml
5.4 Analytical balance, accuracy 0,1 mg
5.5 Pipettes from 100 [mu]l to 10 ml, glass or plastics,
(high density polyethylene/polypropylene)
5.6 Atomic absorption spectrometer with an appropriate
detection system and sensitivity
6 Preparation of sample
7 Procedure
7.1 General
7.2 Preparation of reference solution
7.3 Determination of mercury
7.3 1 General
7.3.2 Standard additions
7.4 Determination of blank value
8 Expression of results
9 Precision
10 Test report
This European Standard is one in a series of Standards for the determination of heavy metals in an aqueous extract of paper and paperboard intended for contact with food. This European Standard specifies the test method for the determination of mercury in an aqueous extract.It is applicable to paper and board with extractable mercury content exceeding 0,06 mg per kg.NOTE 1The above limit of determination is 5 times below than the actual limit existing today or proposed in Europe.NOTE 2Mercury content levels below 0,06 mg per kg can be measured by this European Standard if very sensitive equipment is available and if all other laboratory conditions fulfil the requirements for trace element analysis.
Committee |
CEN/TC 172
|
DevelopmentNote |
Supersedes ENV 12497 (11/2005)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 12497:2006 | Identical |
SN EN 12497 : 2005 | Identical |
UNI EN 12497 : 2005 | Identical |
BS EN 12497:2005 | Identical |
NEN EN 12497 : 2005 | Identical |
NF EN 12497 : 2005 | Identical |
DIN EN 12497:2005-11 | Identical |
NBN EN 12497 : 2005 | Identical |
NS EN 12497 : 1ED 2005 | Identical |
I.S. EN 12497:2005 | Identical |
PN EN 12497 : NOV 2006 | Identical |
EN 645:1993 | Paper and board intended to come into contact with foodstuffs - Preparation of a cold water extract |
EN 647:1993 | Paper and board intended to come into contact with foodstuffs - Preparation of a hot water extract |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.