EN 1060-4:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers

Superseded date

01-04-2014

Published date

29-09-2004

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 General information on the non-invasive reference methods
  4.2 General information on the invasive reference methods
  4.3 Selection of clinical test method
  4.4 Application of test method
      4.4.1 Non-invasive reference measurement
      4.4.2 Invasive reference measurement
  4.5 Test equipment
      4.5.1 Non-invasive reference measurement
      4.5.2 Invasive blood pressure measurement
  4.6 Subjects
      4.6.1 General
      4.6.2 Non-invasive reference measurement
      4.6.3 Invasive reference measurement
  4.7 Cuff size
  4.8 Procedure
  4.9 Evaluation of results
      4.9.1 General
      4.9.2 Non-invasive reference measurement
      4.9.3 Documentation
5 Non-invasive test methods
  5.1 Test method N1 - simultaneous blood pressure
      measurement on the same upper arm
      5.1.1 Procedure
      5.1.2 Evaluation
  5.2 Test method N2 - blood pressure measurement on
      the opposite arms
      5.2.1 Procedure
      5.2.2 Evaluation
      5.2.3 Documentation
  5.3 Test method N3 - sequential blood pressure measurement
      on the same arm
      5.3.1 Procedure
      5.3.2 Evaluation
  5.4 Test method N4 - simultaneous blood pressure measurement
      on the same upper arm at restand under physical load
      5.4.1 Procedure
      5.4.2 Evaluation
      5.4.3 Documentation
  5.5 Test method N5 - ambulatory blood pressure measurement
      on the same upper arm
      5.5.1 Procedure of measurement
      5.5.2 Evaluation
      5.5.3 Documentation
  5.6 Test method N6 - ambulatory blood pressure measurement
      on the opposite arms
      5.6.1 Procedure
      5.6.2 Evaluation
      5.6.3 Documentation
6 Invasive test methods
  6.1 Test method I 1 - invasive blood pressure measurement
      on adults
      6.1.1 Procedure
      6.1.2 Evaluation
      6.1.3 Documentation
  6.2 Test method I 2 - invasive blood pressure measurement
      on neonates and infants
      6.2.1 Procedure
      6.2.2 Evaluation
      6.2.3 Documentation
Annex A (informative) Chronological order of the test
        method N3 Sequential blood pressure measurement
        on the same arm
Annex B (informative) Example of a record of a clinical
        investigation according to method N1 or N3
Annex C (informative) Summary of the WHO recommendations
        for auscultatory blood pressure measurement
Annex D (informative) Observer training and assessment etc.
Annex E (informative) A-deviations
Annex ZA (informative) Relationship between this European
        Standard and the Essential Requirements of
        EU Directive 93/42/EC Medical Devices
Bibliography

This document describes test procedures for investigations to determine the overall system accuracy of automated non-invasive sphygmomanometers, designed for the indirect measurement of blood pressure.

Committee
CEN/TC 205
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded

Standards Relationship
NBN EN 1060-4 : 2004 Identical
DIN EN 1060-4:2004-12 Identical
PN EN 1060-4 : 2005 Identical
SN EN 1060-4 : 2005 Identical
BS EN 1060-4:2004 Identical
UNE-EN 1060-4:2005 Identical
NEN EN 1060-4 : 2004 Identical
UNI EN 1060-4 : 2005 Identical
NF EN 1060-4 : 2004 Identical
NS EN 1060-4 : 1ED 2004 Identical
I.S. EN 1060-4:2004 Identical

AAMI TIR44 : 2012 NON-INVASIVE BLOOD PRESSURE MOTION ARTIFACT - TESTING AND EVALUATION OF NIBP DEVICE PERFORMANCE IN THE PRESENCE OF MOTION ARTIFACT
DIN EN 1060-3:2010-03 NON-INVASIVE SPHYGMOMANOMETERS - PART 3: SUPPLEMENTARY REQUIREMENTS FOR ELECTRO-MECHANICAL BLOOD PRESSURE MEASURING SYSTEMS
EN 1060-3:1997+A2:2009 Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems
I.S. EN ISO 81060-2:2014 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF AUTOMATED MEASUREMENT TYPE (ISO 81060-2:2013)
17/30357644 DC : 0 BS EN ISO 81060-2 - NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF INTERMITTENT AUTOMATED MEASUREMENT TYPE
UNI EN ISO 81060-2 : 2014 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF AUTOMATED MEASUREMENT TYPE
CSA ISO 81060-2 : 2014 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF AUTOMATED MEASUREMENT TYPE
I.S. EN 1060-3:1997 NON-INVASIVE SPHYGMOMANOMETERS - PART 3: SUPPLEMENTARY REQUIREMENTS FOR ELECTRO-MECHANICAL BLOOD PRESSURE MEASURING SYSTEMS
DIN EN ISO 81060-2:2014-10 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVASTIGATION OF AUTOMATED MEASUREMENT TYPE (ISO 81060-2:2013)
AAMI ISO 81060-2 : 2013 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF AUTOMATED MEASUREMENT TYPE
BS EN ISO 81060-2:2014 Non-invasive sphygmomanometers Clinical investigation of automated measurement type
ISO 81060-2:2013 Non-invasive sphygmomanometers Part 2: Clinical investigation of automated measurement type
UNI EN 1060-3 : 2010 NON-INVASIVE SPHYGMOMANOMETERS - PART 3: SUPPLEMENTARY REQUIREMENTS FOR ELECTRO-MECHANICAL BLOOD PRESSURE MEASURING SYSTEMS
EN ISO 81060-2:2014 Non-invasive sphygmomanometers - Part 2: Clinical investigation of automated measurement type (ISO 81060-2:2013)
BS ISO 81060-2 : 2013 NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL INVESTIGATION OF AUTOMATED MEASUREMENT TYPE
08/30174059 DC : DRAFT JUNE 2008 BS ISO 81060-2 - NON-INVASIVE SPHYGMOMANOMETERS - PART 2: CLINICAL VALIDATION OF AUTOMATED MEASUREMENT TYPE
UNE-EN ISO 81060-2:2014 Non-invasive sphygmomanometers - Part 2: Clinical investigation of automated measurement type (ISO 81060-2:2013)
BS EN 1060-3 : 1997 NON-INVASIVE SPHYGMOMANOMETERS - PART 3: SUPPLEMENTARY REQUIREMENTS FOR ELECTRO-MECHANICAL BLOOD PRESSURE MEASURING SYSTEMS

EN 1060-2:1995+A1:2009 Non-invasive sphygmomanometers - Part 2: Supplementary requirements for mechanical sphygmomanometers
EN 1060-1:1995+A2:2009 Non-invasive sphygmomanometers - Part 1: General requirements
ISO 14155-2:2003 Clinical investigation of medical devices for human subjects Part 2: Clinical investigation plans
ISO 14155-1:2003 Clinical investigation of medical devices for human subjects Part 1: General requirements
EN ISO 14155-2:2009 Clinical investigation of medical devices for human subjects - Part 2: Clinical investigation plans (ISO 14155-2:2003)
EN ISO 14155-1:2009 Clinical investigation of medical devices for human subjects - Part 1: General requirements (ISO 14155-1:2003)
EN 1060-3:1997+A2:2009 Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.