TIME SWITCHES FOR TARIFF AND LOAD CONTROL
01-06-2005
12-01-2013
Vorwort
Erklärung
Anerkennungsnotiz
Abschnitt
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Anforderungen
5 Prüfungen und Prüfbedingungen
Anhänge (normativ)
A Beziehung zwischen Umgebungstemperatur und
relativer Luftfeuchte
B Bezugs- und Grenzwerte der Einflussgrössen
C Elektromagnet für die Prüfung der Störfestigkeit
gegen magnetische Gleichfelder
ZA Andere in dieser Norm zitierte internationale
Publikationen mit den Verweisungen der
entsprechenden europäischen Publikationen
Anhang (informativ)
D Annahmeprüfungen
Gives requirements for testing newly manufactured indoor time switches with operation reserve that are used to control electrical loads, multi-tariff registers and maximum demand devices at certain periods throughout the year. May employ various techniques for electronic circuits. Does not apply to time switches operated by remote control or synchronized by radio-frequency. Covers normative references, definitions, requirements, tests and test conditions, relationship between ambient air temperature and relative humidity, reference and limiting values of the influence quantities, electromagnet for testing the influence quantities, electromagnet for testing the influence of externally produced magnetic field and acceptance tests.
DocumentType |
Standard
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61038 : 93 AMD 2 98 | Identical |
NBN EN 61038 : 93 AMD 2 98 | Identical |
SN EN 61038 : AMD 2 1998 | Identical |
I.S. EN 61038:1993 | Identical |
VDE 0419-1 : 94 AMD 2 99 | Corresponds |
BS EN 61038:1993 | Identical |
EN 61038:1992/A2:1998 | Identical |
IEC 61038:1990+AMD1:1996+AMD2:1998 CSV | Identical |
VDE 0419-1 : 94 AMD 2 99 | Identical |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
DIN IEC 60068-2-27:1989-08 | ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TEST Ea AND GUIDANCE; SHOCK |
DIN IEC 60068-2-1:1985-08 | ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TESTS A: COLD |
DIN VDE 0110-1 : 1997 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
DIN IEC 60068-2-30:1986-09 | ELECTRICAL ENGINEERING - BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST DB AND GUIDANCE - DAMP HEAT, CYCLIC (12 + 12 HOUR CYCLE) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
DIN ISO 2859-1:2014-08 | SAMPLING PROCEDURES FOR INSPECTION BY ATTRIBUTES - PART 1: SAMPLING SCHEMES INDEXED BY ACCEPTANCE QUALITY LIMIT (AQL) FOR LOT-BY-LOT INSPECTION (ISO 2859-1:1999 + COR. 1:2001 + AMD.1:2011) |
DIN VDE 0843-3 : 1988 | ELECTROMAGNETIC COMPATIBILITY FOR INDUSTRIAL PROCESS MEASUREMENT AND CONTROL EQUIPMENT - RADIATED ELECTROMAGNETIC FIELD REQUIREMENTS |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
IEC 60817:1984 | Spring-operated impact-test apparatus and its calibration |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
DIN VDE 0636-10 : 1992 | LOW-VOLTAGES FUSES; GENERAL REQUIREMENTS |
DIN 40050-9:1993-05 | ROAD VEHICLES; DEGREES OF PROTECTION (IP-CODE); PROTECTION AGAINST FOREIGN OBJECTS, WATER AND CONTACT; ELECTRICAL EQUIPMENT |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
DIN IEC 60721-3-3:1990-04 | ELECTRICAL ENGINEERING; CLASSIFICATION OF ENVIRONMENTAL CONDITIONS; CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES; STATIONARY USE AT WEATHER PROTECTED LOCATIONS |
IEC 60801-3:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
DIN IEC 60068-2-2:1980-03 | BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TESTS B: DRY HEAT |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.