1 Field of application
2 Symbols
3 Test configuration
      3.1 General
      3.2 Dimensions, auxiliary structures and positioning
             of test sheets
      3.3 'Single-span beam' test (Test A)
      3.4 'Intermediate support' test (Test B)
      3.5 'End support' test (Test C)
      3.6 'Multiple-span beam' test (Test D)
      3.7 Impact (walkability) test (Test E)
4 Test procedure
      4.1 General
      4.2 Measurement of profile dimensions
      4.3 Determination of self-weight of loading device
      4.4 Rate of loading
      4.5 Materials testing
5 Number of tests
      5.1 Minimum number of sheet thicknesses to be tested
      5.2 Minimum number of tests
      5.3 Minimum number of effective spans to be tested
             in Tests B and D
6 Presentation of results
7 Evaluation of test results
      7.1 General
      7.2 Action-effects
      7.3 Test A
      7.4 Test B
      7.5 Test C
      7.6 Test D
      7.7 Test E
8 Design
Standards and other documents referred to

Deals with the procedure and evaluation of tests for determining the loadbearing capacity of corrosion-protected trapezoidal (profiled) steel sheeting subjected to predominantly static loading (c.f. sub-clause 1.4 of DIN 1055 Part 3, June 1971 edition), which is used in building construction for roofs, floors, walls and wall cladding (see Figure 2 in DIN 18807 Part 1, June 1997 edition, for examples of profiled types).

DocumentType
Standard
Pages
10
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Withdrawn

DIN 18807-2 : 1987 AMD 1 2001 TRAPEZOIDAL SHEETING IN BUILDING - STEEL TRAPEZOIDAL SHEETING - EXECUTION AND EVALUATION OF ULTIMATE STRENGTH TESTS
DIN 18807-3:1987-06 TRAPEZOIDAL SHEETING IN BUILDING - STEEL TRAPEZOIDAL SHEETING - STRENGTH ANALYSIS, STRUCTURAL DESIGN
DIN 18807-1 : 1987 AMD 1 2001 TRAPEZOIDAL SHEETING IN BUILDING - TRAPEZOIDAL STEEL SHEETING - GENERAL REQUIREMENTS AND DETERMINATION OF LOADBEARING CAPACITY BY CALCULATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.