DEFSTAN 02-603/2(2001) : INTERIM
Current
The latest, up-to-date edition.
REQUIREMENTS FOR THE POLICY, DESIGN AND INSTALLATION OF FIRE DETECTION SYSTEMS IN SHIPS
Hardcopy , PDF
English
01-06-2001
TITLE PAGE
SCOPE
FOREWORD
Sponsorship
Conditions of Release
Categories of NES
Related Documents
Health and Safety
Additional Information
CONTENTS
SECTION 1. POLICY STATEMENT
1.1 Fighting Ships and Submarines
1.2 Commercial Standard Ships
1.3 Vessels Refitting
SECTION 2. GENERAL REQUIREMENTS
2.1 Function
2.2 Control
2.3 Testing
2.4 Autonomy
2.5 Environment
2.6 Requirement
2.7 Statutory Regulations (SI 1984/1218 and amendments)
SECTION 3. COMPARTMENTS AND SPACES
3.1 Requirements
3.2 Explosive Risk
3.3 High Fire Risk
3.4 Ventilation Trunking
3.5 Statutory Regulations (SI 1984/1218 and SI
1981/1774 and amendments)
SECTION 4. SYSTEM DESIGN
4.1 System Response
4.2 Detectors
4.3 Architecture
4.4 Redundancy
Table 4.1 Smoke Detectors
4.5 Data Transmission
4.6 Interface with Other Systems
4.7 Statutory Regulations (SI 1984/1218 and amendments)
Table 4.2 Maximum Spacing of Detectors
(SI 1984/1218 Schedule 11)
SECTION 5. METHODS OF DETECTING FIRE
5.1 Effects of Fire
5.2 Heat Detectors
5.3 Smoke Detectors
5.4 Flame Detectors
5.5 Performance of Heat Detectors
Table 5.1 Heat Detector Temperature Ranges
5.6 Performance of Smoke Detectors
5.7 Performance of Flame Detectors
5.8 Selection of Detectors
5.9 Explosive and High Fire Risk Areas
5.10 Statutory Regulations (SI 1984/1218 and amendments)
SECTION 6. MOUNTING OF DETECTORS
6.1 Mounting Base
6.2 Position of Detectors
Table 6.1 Recommended Limits for Deckhead Heights
6.2 Position of Detectors
6.3 Spacing
Table 6.2 Recommended Coverage per Detector for
EDP Installations
6.4 Environment
6.5 Statutory Regulations (SI 1984/1218 and amendments)
SECTION 7. CONTROLS AND INDICATORS
7.1 Requirements
7.2 Response to Alarms
7.3 Manual Controls
7.4 Event Logging
7.5 Malfunctions
7.6 Indicators
7.7 Location of Controls and Indicators
7.8 Statutory Regulations (SI 1984/1218 and amendments)
SECTION 8. ALARMS
Table 8.1 Sound Attenuation up to 24 m
8.2 Fault Warning Sounder
8.3 Visual Indicators
8.4 High Intensity Beacons
8.5 Statutory Regulations (SI 1984/1218 and amendment)
SECTION 9. SYSTEM INSTALLATION
9.1 Selection of Cables
Table 9.1 Conductor Sizes
9.2 Installation of Cables
9.3 Siting of System Components
9.4 Mounting of Components
9.5 Intrinsically Safe Circuits
9.6 Precautions
9.7 Statutory Regulations (SI 1984/1218 and amendments)
SECTION 10. POWER SUPPLIES
10.1 Fighting Ships and Submarines
10.2 Commercial Standard Ships
10.3 Statutory Regulations (SOLAS Reg II-2)
SECTION 11. TESTS
11.1 Functional Tests
11.2 Electrical Tests
11.3 Statutory Regulations (SI 1984/1218 and amendments)
ANNEX A. RELATED DOCUMENTS
ANNEX B. ABBREVIATIONS, DEFINITIONS, SYMBOLS AND
UNITS
Table B.1 Symbols and Units for Fire Detection
ANNEX C. PROCUREMENT CHECK LIST
ANNEX D. FIRE AND SMOKE DETECTOR AND ALARM
SYSTEMS FOR MERCHANT SHIPS
Table D.1 Classification of Passenger Ships
Table D.2 Classification of Ships Other Than Passenger Ships
Table D.3 Fire Detection Regulations and Requirements for
Merchant Ships
ANNEX E. SPACES AND COMPARTMENTS
Table E.1 Spaces and Compartments in RN and RFA Ships which
require Fire Detectors Prior to 1998
ALPHABETICAL INDEX
Describes the shipwide fire detection systems. The main fire detection control panel and detectors shall form an Autonomous Fire Detection and Alarm System (AFDAS). The basic general principles of this Defence Standard are to be applied to any fire detection systems that are fitted.
DevelopmentNote |
Supersedes DEFSTAN 02-603/1(2000) (11/2001)
|
DocumentType |
Miscellaneous Product
|
Pages |
82
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Current
|
Supersedes |
DEFSTAN 00-101(PT2)/1(2005) : 2005 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 2: SUBMARINES |
DEFSTAN 00-101(PT3)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION |
DEFSTAN 02-357(PT1)/2(2009) : 2009 | REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN AND AUXILIARY MACHINERY SPACES ON SURFACE SHIPS - PART 1: GENERAL REQUIREMENTS FOR CARBON DIOXIDE SYSTEMS |
DEFSTAN 00-101(PT1)/1(2005) : 2005 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 1: SURFACE SHIPS |
DEFSTAN 00-101(PT1)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 1: SURFACE SHIPS |
DEFSTAN 02-885(PT1)/1(2015) : 2015 | REQUIREMENTS FOR FIRE PROTECTION OF ELECTRICAL AND ELECTRONIC EQUIPMENT CABINETS ON HM SURFACE SHIPS AND SUBMARINES - PART 1: LOW VOLTAGE AND EXTRA LOW VOLTAGE EQUIPMENT |
DEFSTAN 02-357(PT4)/1(2010) : 2010 | REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN AND AUXILIARY MACHINERY SPACES ON SURFACE SHIPS - PART 4: GENERAL REQUIREMENTS FOR INERT GAS SYSTEMS INCLUDING ELECTRIC/ELECTRONIC SPACES |
DEFSTAN 00-101(PT2)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 2: SUBMARINES |
DEFSTAN 02-726/2(2001) : 2001 | REQUIREMENTS FOR CLEANLINESS OF SHIPS DURING BUILD CATEGORY 3 |
BS EN 60651:1994 | Specification for sound level meters |
BS EN 54-7:2001 | Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization |
BS EN 54-1:2011 | Fire detection and fire alarm systems Introduction |
DEFSTAN 08-123/1(2000) : 2000 | REQUIREMENTS FOR THE DESIGN AND TESTING OF EQUIPMENTS TO MEET ENVIRONMENTAL CONDITIONS - CATEGORY 2 |
DEFSTAN 02-119(PT3)/1(2000) : 2000 | THE REQUIREMENTS FOR FIRE PROTECTION AND DAMAGE CONTROL FOR SURFACE SHIPS - PART 3: SURFACE SHIP AND SUBMARINE EQUIPMENT CATEGORY 2 |
STANAG 1169 : 0 | FIRE FIGHTING EQUIPMENT AND PRINCIPLES FOR HARMONIZATION OF PRESENT AND FUTURE EQUIPMENT AND MATERIALS |
DEFSTAN 02-523/1(2000) : 2000 | GUIDE TO THE INSTALLATION OF THIN - WALL INSULATED, LIMITED FIRE HAZARD EQUIPMENT WIRE AND ELECTRIC CABLE CATEGORY 3 |
DEFSTAN 07-226/2(2001) : 2001 | REQUIREMENTS FOR ELECTRICAL TESTING OF EQUIPMENT - CATEGORY 2 |
DEFSTAN 02-119(PT1)/1(2000) : 2000 | THE REQUIREMENTS FOR FIRE PROTECTION AND DAMAGE CONTROL FOR SURFACE SHIPS - PART 1: POLICY FOR SURFACE SHIPS CATEGORY 2 |
BS EN 54-5 : 2017 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS |
DEFSTAN 08-107/2(2001) : 2001 | GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROMECHANICAL AND NAVAL WEAPON EQUIPMENT - CATEGORY 2 |
BS 5345-4:1977 | Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection \'i\'. Intrinsically safe electrical apparatus and systems |
DEFSTAN 08-101(PT2)/1(2000) : 2000 | REQUIREMENTS FOR THE CONSTRUCTION AND SYSTEM ARRANGEMENTS IN MAGAZINES AND WEAPON STORAGE COMPARTMENTS - CATEGORY 1 - PART 2: HM SUBMARINES |
BS 5501-7:1977 | Electrical apparatus for potentially explosive atmospheres Intrinsic safety \'i\' |
DEFSTAN 02-775/1(2000) : 2000 | GASOLINE SYSTEMS AND STOWAGES CATEGORY 2 |
DEFSTAN 07-228/1(2000) : 2000 | REQUIREMENTS AND SAFETY REGULATIONS FOR ELECTRICAL EQUIPMENT AND INSTALLATIONS FITTED IN MAGAZINES, SUBMARINE WEAPON STORAGE COMPARTMENTS, ADJACENT COMPARTMENTS AND DESIGNATED AREAS - CATEGORY 1 |
DEFSTAN 61-5(PT4)/2(1992) : 1992 | ELECTRICAL POWER SUPPLY SYSTEMS BELOW 650 VOLTS - PART 4: POWER SUPPLIES IN HM SHIPS |
BS 4568-2:1970 | Specification for steel conduit and fittings with metric threads of ISO form for electrical installations Fittings and components |
DEFSTAN 02-626/1(2000) : 2000 | CONTROL AND SURVEILLANCE EQUIPMENT FOR PLANT AND SYSTEM INSTALLATIONS CATEGORY 2 |
BS 5839-4:1988 | Fire detection and alarm systems for buildings Specification for control and indicating equipment |
BS 4547:1972 | Classification of fires |
BS 5839-2:1983 | Fire detection and alarm systems for buildings Specification for manual call points |
DEFSTAN 08-101(PT1)/1(2000) : 2000 | REQUIREMENTS FOR THE CONSTRUCTION AND SYSTEM ARRANGEMENTS IN MAGAZINES AND WEAPON STORAGE COMPARTMENTS - CATEGORY 1 - PART 1: HM SURFACE SHIPS |
DEFSTAN 02-102(PT1)/2(2000) : 2000 | REQUIREMENTS FOR AIR CONDITIONING & VENTILATION - PART 1: HM SURFACE SHIPS AND ROYAL FLEET AUXILIARIES |
BS 4568-1:1970 | Specification for steel conduit and fittings with metric threads of ISO form for electrical installations Steel conduit, bends and couplers |
BS EN 2:1992 | Classification of fires |
DEFSTAN 02-620/1(2000) : 2000 | REQUIREMENTS FOR SOFTWARE FOR USE WITH DIGITAL PROCESSORS CATEGORY 3 |
DEFSTAN 02-525/1(2000) : 2000 | REQUIREMENTS FOR ELECTRIC CABLES, THIN - WALL INSULATED, LIMITED FIRE HAZARD CATEGORY 2 |
DEFSTAN 02-502/1(2000) : 2000 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS CATEGORY 2 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.