• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA ISO/IEC 8802-3 : 2002 : R2016

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 3: CARRIER SENSE MULTIPLE ACCESS WITH COLLISION DETECTION (CSMA/CD) ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS

Available format(s)

Hardcopy , PDF

Withdrawn date

28-08-2018

Language(s)

English

Published date

01-01-2016

£486.05
Excluding VAT

1. Introduction
2. Media Access Control (MAC) service specification
3. Media access control frame structure
4. Media Access Control
5. Layer Management
6. Physical Signaling (PLS) service specifications
7. Physical Signaling (PLS) and Attachment Unit Interface
    (AUI) specifications
8. Medium Attachment Unit and baseband medium
    specifications, type 10BASE5
9. Repeater unit for 10 Mb/s baseband networks
10. Medium attachment unit and baseband medium
    specifications, type 10BASE2
11. Broadband medium attachment unit and broadband
    medium specifications, type 10BROAD36
12. Physical signaling, medium attachment, and baseband
    medium specifications, type 1BASE5
13. System considerations for multisegment 10 Mb/s
    baseband networks
14. Twisted-pair medium attachment unit (MAU) and
    baseband medium, type 10BASE-T
15. Fiber optic medium and common elements of medium
    attachment units and star, type 10BASE-F
16. Fiber optic passive star and medium attachment unit,
    type 10BASE-FP
17. Fiber optic medium attachment unit, type 10BASE-FB
18. Fiber optic medium attachment unit, type 10BASE-FL
19. Layer Management for 10 Mb/s baseband repeaters
20. Layer Management for 10 Mb/s baseband medium
    attachment units
21. Introduction to 100 Mb/s baseband networks, type
    100BASE-T
22. Reconciliation Sublayer (RS) and Media Independent
    Interface (MII)
23. Physical Coding Sublayer (PCS), Physical Medium
    Attachment (PMA) sublayer and baseband medium,
    type 100BASE-T4
24. Physical Coding Sublayer (PCS) and Physical Medium
    Attachment (PMA) sublayer, type 100BASE-X
25. Physical Medium Dependent (PMD) sublayer and
    baseband medium, type 100BASE-TX
26. Physical Medium Dependent (PMD) sublayer and
    baseband medium, type 100BASE-FX
27. Repeater for 100 Mb/s baseband networks
28. Physical Layer link signaling for 10 Mb/s, 100 Mb/s,
    and 1000 Mb/s Auto-Negotiation on twisted pair
29. System considerations for multisegment 100BASE-T
    networks
30. 10 Mb/s, 100 Mb/s, 1000 Mb/s, MAC Control, and
    Link Aggregation Management
31. MAC Control
32. Physical Coding Sublayer (PCS), Physical Medium
    Attachment (PMA) sublayer and baseband medium,
    type 100BASE-T2
33. Clause 33 is reserved for future use
34. Introduction to 1000 Mb/s baseband network
35. Reconciliation Sublayer (RS) and Gigabit Media
    Independent Interface (GMII)
36. Physical Coding Sublayer (PCS) and Physical Medium
    Attachment (PMA) sublayer, type 1000BASE-X
37. Auto-Negotiation function, type 1000BASE-X
38. Physical Medium Dependent (PMD) sublayer and
    baseband medium, type 1000BASE-LX (Long
    Wavelength Laser) and 1000BASE-SX (Short
    Wavelength Laser)
39. Physical Medium Dependent (PMD) sublayer and
    baseband medium, type 1000BASE-CX (short-haul
    copper)
40. Physical Coding Sublayer (PCS), Physical Medium
    Attachment (PMA) sublayer and baseband medium,
    type 1000BASE-T
41. Repeater for 1000 Mb/s baseband networks
42. System considerations for multisegment 1000 Mb/s
    networks
43. Link Aggregation
Annex A (informative) - Additional reference material
Annex B (informative) - System guidelines
Annex C (informative) - State diagram, MAC sublayer
Annex D (informative) - Application context, selected
        medium specifications
Annex E (informative) - Receiver wavelength design
        considerations (FOIRL)
Annex F (normative) - Additional attributes required
        for systems
Annex G (normative) - Additional material required for
        conformance testing
Annex H (normative) - GDMO specifications for
        CSMA/CD managed objects
Annex 22A (informative) - MII output delay, setup, and
          hold time budget
Annex 22B (informative) - MII driver ac characteristics
Annex 22C (informative) - Measurement techniques for
          MII signal timing characteristics
Annex 23A (normative) - 6T code words
Annex 23B (informative) - Noise budget
Annex 23C (informative) - Use of cabling systems with
          a nominal differential characteristic impedance
          of 120 [Omega]
Annex 27A (normative) - Repeater delay consistency
          requirements
Annex 28A (normative) - Selector Field definitions
Annex 28B (normative) - IEEE 802.3 Selector Base
          Page definition
Annex 28C (normative) - Next Page Message Code
          Field definitions
Annex 28D (normative) - Description of extensions to
          Clause 28 and associated annexes
Annex 29A (informative) - DTE and repeater delay
          components
Annex 29B (informative) - Recommended topology
          documentation
Annex 30A (normative) - GDMO specification for
          802.3 managed object classes
Annex 30B (normative) - GDMO and ASN.1 definitions
          for management
Annex 30C (normative) - SNMP MIB definitions for
          Link Aggregation
Annex 31A (normative) - MAC Control opcode assignments
Annex 31B (normative) - MAC Control PAUSE operation
Annex 32A (informative) - Use of cabling systems
          with nominal differential characteristic impedance
          of 120 [OMEGA] or 150 [OMEGA]
Annex 36A (informative) - Jitter test patterns
Annex 36B (informative) - 8B/10B transmission code
          running disparity calculation examples
Annex 38A (informative) - Fiber launch conditions
Annex 40A (informative) - Additional cabling design
          guidelines
Annex 40B (informative) - Description of cable clamp
Annex 40C (informative) - Add-on interface for additional
          Next Pages
Annex 43A (informative) - Collection and Distribution
          functions
Annex 43B (normative) - Requirements for support of
          Slow Protocols
Annex 43C (informative) - LACP standby link selection
          and dynamic Key management

Intends to encompass several media types and techniques for signal rates of from 1 Mb/s to 20 Mb/s. Provides the necessary specifications for 10 Mb/s baseband and broadband systems, a 1 Mb/s baseband system, and a Repeater Unit.

DocumentType
Standard
Pages
1562
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Withdrawn
Supersedes

Standards Relationship
ISO/IEC 8802-3:2000 Identical

IEC 60950:1999 Safety of information technology equipment
IEC 60794-1:1996 Optical fibre cables - Part1: Generic specification (Revision to IEC 794-1)
IEC 60793-2:2015 Optical fibres - Part 2: Product specifications - General
IEC 60874-2:1993 Connectors for optical fibres and cables - Part 2: Sectional specification for fibre optic connector - Type F-SMA
IEC 60793-1:1992 Optical fibres - Part 1: Generic specification
ISO/IEC 8877:1992 Information technology Telecommunications and information exchange between systems Interface connector and contact assignments for ISDN Basic Access Interface located at reference points S and T
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 60874-1:2011 Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 1: Generic specification
IEC 60169-8:1978 Radio-frequency connectors. Part 8: R.F. coaxial connectors with inner diameter of outer conductor 6.5 mm (0.256 in) with bayonet lock - Characteristic impedance 50 ohms (Type BNC)
ISO/IEC 2382-9:1995 Information technology Vocabulary Part 9: Data communication
IEC 60794-2:2017 Optical fibre cables - Part 2: Indoor cables - Sectional specification
ISO/IEC 7498-4:1989 Information processing systems — Open Systems Interconnection — Basic Reference Model — Part 4: Management framework
IEC 60380:1985 Safety of electrically energized office machines

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.