PRINCIPLES AND PRACTICES OF ELECTRICAL COORDINATION BETWEEN PIPELINES AND ELECTRIC SUPPLY LINES
Hardcopy , PDF
24-09-2020
English, French
01-01-2017
Preface
1 Scope
2 Reference publications
3 Definitions
4 General considerations
5 Pipeline design considerations for the mitigation of
mutualinterference effects between power lines and
pipelines
6 Power line design considerations for the mitigation
of mutual interference effects between power lines and
pipelines
7 Mitigation of induced voltage effects during pipeline
construction
8 Pipeline and power line operation and maintenance
Annex A (informative) - Principles of mutual interference
between power lines and pipelines
Annex B (informative) - Sensitivity of induction from power
lines to pipelines
Annex C (informative) - Underground transmission cables
Annex D (informative) - AC corrosion
Annex E (informative) - Recommendations for the exchange of
information
Annex F (informative) - Example of a gradient mat study
Annex G (informative) - Bibliography
Describes methods of electrical coordination between pipelines and alternating current (ac) supply lines having line-to-line voltages greater than 60 kV that are simultaneously or separately installed as follows: a) a pipeline located on a power line right-of-way or a power line located on a pipeline right-of-way; b) a pipeline right-of-way located parallel to a power line right-of-way, or vice versa, where the adjacent right-of-way boundaries are within 300 m of each other; and c) laterals and extensions to the pipelines described in Item (a) or (b).
DevelopmentNote |
French Edition issued on 01-10-2013. (12/2013)
|
DocumentType |
Standard
|
Pages |
63
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
CAN/CSA-Z662-15 | Oil and gas pipeline systems |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
NACE SP 01 77 : 2014 | MITIGATION OF ALTERNATING CURRENT AND LIGHTNING EFFECTS ON METALLIC STRUCTURES AND CORROSION CONTROL SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.