CSA C22.2 No. 60079-11 : 2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'

Available format(s)

Hardcopy , PDF

Superseded date

10-09-2021

Language(s)

English - French

Published date

01-02-2014

£268.75
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Grouping and classification of intrinsically safe apparatus
   and associated apparatus
5 Levels of protection and ignition compliance requirements
   of electrical apparatus
6 Apparatus construction
7 Components on which intrinsic safety depends
8 Infallible components, infallible assemblies of components
   and infallible connections on which intrinsic safety depends
9 Supplementary requirements for specific apparatus
10 Type verifications and type tests
11 Routine verifications and tests
12 Marking
13 Documentation
Annex A (normative) - Assessment of intrinsically safe circuits
Annex B (normative) - Spark test apparatus for intrinsically
        safe circuits
Annex C (informative) - Measurement of creepage distances,
        clearances and separation distances through casting
        compound and through solid insulation
Annex D (normative) - Encapsulation
Annex E (informative) - Transient energy test
Annex F (normative) - Alternative separation distances for
        assembled printed circuit boards and separation of
        components
Annex G (normative) - Fieldbus intrinsically safe concept
        (FISCO) - Apparatus requirements
Annex H (informative) - Ignition testing of semiconductor
        limiting power supply circuits
Bibliography
Annex HA (normative) - Intrinsically safe and associated
         equipment for use in Class I, II, and III, Division 1
         hazardous locations

This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres.

DevelopmentNote
Supersedes CSA E60079.11. (04/2012)
DocumentType
Standard
ISBN
978-1-77139-322-5
Pages
326
PublisherName
Canadian Standards Association
Status
Superseded

CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 61158-2:2014 Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition
CSA C22.2 No. 25 : 1966 ENCLOSURES FOR USE IN CLASS 2, DIVISION 1, GROUPS E, F, AND G HAZARDOUS LOCATIONS
IEC 60317-3:2004+AMD1:2010 CSV Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155
IEC 60317-7:1990+AMD1:1997+AMD2:1997 CSV Specifications for particular types of winding wires - Part 7: Polyimide enamelled round copper wire, class 220
IPC 2152 : 0 STANDARD FOR DETERMINING CURRENT CARRYING CAPACITY IN PRINTED BOARD DESIGN
IEC 60317-8:2010 Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180
IEC 62013-1:2005 Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
CSA C22.2 No. 60529 : 2016 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
IEC 60317-13:2010 Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200
IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
C22.2 NO. 213-17 Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations (Binational standard with UL 121201)
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 61086-1:2004 Coatings for loaded printed wire boards (conformal coatings) - Part 1: Definitions, classification and general requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.