CISPR TR 16-2-5:2008
Current
The latest, up-to-date edition.
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-5: In situ measurements for disturbing emissions produced by physically large equipment
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
09-07-2008
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Methodology
4.1 Structure of each measurement
4.2 Preliminary measurements and selection of
measurement method
4.3 Selection of the EUT mode of operation and the
reference point depending on the environment
4.4 Assessment of measurement results
5 Method of in situ measurement of conducted disturbance
5.1 General
5.2 Conducted emission measurement procedure
5.2.1 Connection conditions
5.2.2 Reference ground for in situ measurements
5.2.3 Disturbance voltage/current measurements on
cables which carry wanted symmetrical signals
5.2.4 Disturbance voltage measurements on cables which
do not carry wanted symmetrical signals
6 Method of in situ measurement of radiated disturbance
6.1 General
6.2 Measurement conditions
6.3 Measurement methods
6.3.1 Measurement parameters
6.3.2 Measurements in case of interference complaints
6.3.3 Measurements for compliance purposes
6.3.4 Measurements below 30 MHz
7 Measurement report
Bibliography
CISPR 16-2-5:2008(E) deals with in situ electromagnetic disturbance measurements in any environment from physically large equipment and systems excluding networks. It covers both radiated and conducted emission phenomena, and does not deal with immunity tests. This technical report is intended to be applied primarily to such physically large equipment which are not under the scope of any existing emission standards (as for example CISPR 11 and CISPR 22). It serves only as a guideline on how to deal with emissions of that equipment at the particular location of installation. It does not establish any emission requirements. Due to the severe impact of the conditions existing at a particular location of operation and the use of the respective large equipment, however, it is not intended to use the measurements in the frame of type testing. Reference in-situ measurement distances will be given. This allows comparison of the measurement results with limits from existing relevant standards. The frequency range under consideration is from 9 kHz to 18 GHz.
Committee |
CISPR/CIS/H
|
DevelopmentNote |
Stability Date: 2019. (09/2017)
|
DocumentType |
Technical Report
|
Pages |
15
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
AS/NZS CISPR 16.2.5:2013 | Identical |
PD CISPR/TR 16-2-5:2008 | Identical |
09/30148338 DC : 0 | |
BS EN 55011 : 2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
12/30263969 DC : 0 | BS EN 55011 - GENERAL MAINTENANCE FOR CISPR 11 ED.5.1 |
I.S. EN 55011:2016 | INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
IEC 61000-2-4:2002 | Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances |
EN 300 127 : 1.2.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - RADIATED EMISSION TESTING OF PHYSICALLY LARGE TELECOMMUNICATION SYSTEMS |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CLC/TS 50217:2005 | Guide for in situ measurements - In situ measurement of disturbance emission |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 62236-2:2008 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.