CEN/TS 14507-1:2003

Current

Current

The latest, up-to-date edition.

Inhalational nitric oxide systems - Part 1: Delivery systems

Published date

26-03-2003

Sorry this product is not available in your region.

Foreword
Section one - General
1 Scope
2 Normative references
3 Terms and definitions and terminology
4 General requirements and requirements for tests
   4.1 Modifications to clause 3 of the General Standard
   4.2 Modification to clause 4 of the General Standard
5 Classification
6 Identification, marking and documents
   6.1 Marking on the outside of equipment or equipment
       parts
7 Power Input
Section two - Environmental conditions
8 Basic safety categories
9 Removable protective means
10 Environmental conditions
11 Not used
12 Not used
Section three - Protection against electrical shock
                hazards
13 General
14 Requirements related to classification
15 Limitation of voltage and/or energy
16 Enclosures and protective covers
17 Separation
18 Protective earthing, functional earthing and potential
   equalization
19 Continuous leakage current and patient auxiliary
   current
20 Dielectric strength
Section four - Protection against mechanical hazards
21 Mechanical strength
22 Moving parts
23 Surfaces, corners, and edges
24 Stability in normal use
25 Expelled parts
26 Vibration and noise
27 Pneumatic and hydraulic power
28 Suspended masses
Section five - Protection against from unwanted or
               excessive radiation
29 X-Radiation
30 Alpha, beta, gamma, neutron radiation and other particle
   radiation
31 Microwave radiation
32 Light radiation (including lasers)
33 Infra-red radiation
34 Ultra-violet radiation
35 Acoustical energy (including ultrasonics)
36 Electromagnetic compatibility
Section six - Protection against hazards of ignition of
              flammable mixtures
Section seven - Protection against excessive temperatures
                and other safety hazards
42 Excessive temperatures
43 Fire prevention
44 Overflow, spillage, leakage, humidity, ingress of
   liquids, cleaning, sterilization and disinfection
45 Pressure vessels and parts subject to pressure
46 Human errors
47 Electrostatic charges
48 Biocompatibility
49 Interruption of the power supply
Section eight - Accuracy of operation data and protection
                against incorrect output
50 Accuracy of operating data
51 Protection against hazardous output
Section nine - Abnormal operation and fault conditions -
               Environmental tests
52 Abnormal operation and fault conditions
53 Environmental tests
Section ten - Constructional requirements
54 General
55 Enclosures and covers
56 Components and general assembly
57 Mains parts, components and layout
58 Protective earthing - Terminals and connections
59 Construction and layout
Annexes
Annex AA (informative) Rationale
Bibliography

This Part of CEN/TS 14507 refers to EN 60601 1:1990 "Medical electrical equipment - Part 1: General requirements for safety", as amended by its amendments 1 (1991) and 2 (1995). For brevity Part 1 is referred to in this Part of CEN/TS 14507 either as the General Standard or as the General requirements. The scope given in clause 1 of the General Standard applies except that 1.1 is replaced by the following: 1.1This Part of CEN/TS 14507 specifies particular requirements for inhalational nitric oxide delivery systems and their modules. It covers devices which can be supplied in combined units, integrated into another medical device, for example a lung ventilator, or as individual devices. This Part of CEN/TS 14507 addresses the monitoring of nitric oxide and oxygen delivery to the patient and minimization of the production of nitrogen dioxide. This Part of CEN/TS 14507 covers the requirements for inhalational nitric oxide delivery systems intended for medical use, for example, in critical care, anaesthesia, and emergency/transport environments.NOTEIt is recognized that from time to time innovations and designs will appear that offer advantages and yet are not covered by specific safety-related design or performance aspects of this Part of CEN/TS 14507; such innovations are not to be discouraged. As the techniques and technologies in these innovations advance, it is essential that the safety objectives of this Part of CEN/TS 14507 are considered as minimum requirements.The requirements of clause 1.3 of the General Standard apply with the following additions:The numbering of clauses and subclauses of this Part of CEN/TS 14507 corresponds to that of the General Standard. The changes to the text of the General Standard are specified by the use of the following words: ´Replacement´ means that the clause or subclause of the General Standard is replaced completely by the text of this Part of CEN/TS 14507.(...)

Committee
CEN/TC 215
DocumentType
Technical Specification
PublisherName
Comite Europeen de Normalisation
Status
Current

EN 738-1:1997/A1:2002 PRESSURE REGULATORS FOR USE WITH MEDICAL GASES - PRESSURE REGULATORS AND PRESSURE REGULATORS WITH FLOW METERING DEVICES
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
EN 12598 : 1999 OXYGEN MONITORS FOR PATIENT BREATHING MIXTURES - PARTICULAR REQUIREMENTS
EN 475 : 1995 MEDICAL DEVICES - ELECTRICALLY GENERATED ALARM SIGNALS
EN 60068-2-64:2008 ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE
EN 60601-1-6:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-6: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: USABILITY (IEC 60601-1-6:2010/A1:2013)
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60068-2-64:2008 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 739:1998/A1:2002 LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
NFPA 53M : 1990 FIRE HAZARDS IN OXYGEN-ENRICHED ATMOSPHERES
EN 738-3:1998/A1:2002 PRESSURE REGULATORS FOR USE WITH MEDICAL GASES - PART 3: PRESSURE REGULATORS INTEGRATED WITH CYLINDER VALVES
IEC 60068-2-29:1987 Environmental testing. Part 2: Tests. Test Eb and guidance: Bump
CR 13903:2000 General guidance on the equipment used for inhaled nitric oxide therapy
EN ISO 4135:2001 Anaesthetic and respiratory equipment - Vocabulary (ISO 4135:2001)
EN 13221 : 2000 HIGH-PRESSURE FLEXIBLE CONNECTIONS FOR USE WITH MEDICAL GASES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.