CEI CLC/TR 50485 : 2013
Current
The latest, up-to-date edition.
ELECTROMAGNETIC COMPATIBILITY - EMISSION MEASUREMENTS IN FULLY ANECHOIC CHAMBERS
Hardcopy , PDF
English - Italian
01-01-2013
1 Scope
2 References
3 Definitions and abbreviations
4 Test and measurement equipment
5 Anechoic room performance
6 Emission measurement
7 Test procedure
8 Test plan
9 Test report
Annex A (informative) - Determining the Site Reference
Annex B (informative) - Limit values
Annex C (informative) - Comparison of measurement
uncertainties for 3 m OATS and 3 m FAR
Annex D (informative) - Derivation of free space NSA formula
Annex E (informative) - Corrections of field strength for test
distance
Annex F (informative) - NSA measurements with biconical
antennas
Annex G (informative) - Measurement of Balun imbalance
Annex H (informative) - FAR project
Bibliography
Pertains to emission measurements of radiated electromagnetic fields in Fully Anechoic Rooms (FAR) in the frequency range from 30 MHz to 18 GHz.
Committee |
CT 210
|
DevelopmentNote |
Classificazione CEI 210-100. (05/2011)
|
DocumentType |
Standard
|
Pages |
90
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Standards | Relationship |
CLC/TR 50485:2010 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
CLC/TR 50484:2009 | Recommendations for shielded enclosures |
EN 50147-1:1996 | Anechoic chambers - Part 1: Shield attenuation measurement |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
CISPR 16-2:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.