CAN/CSA-ISO/IEC 8802-5-02 (R2011)
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 5: Token Ring Access Method and Physical Layer Specifications (Adopted ISO/IEC 8802-5:1998 / ANSI/IEEE 802.5:1998, third edition, 1998-09-15)
Hardcopy , PDF
14-07-2021
English
01-01-2002
1 Overview
2 General description
3 Formats and facilities
4 Token ring protocols
5 Station-specific components
6 Token ring management
7 Station attachment specifications
8 Concentrator specifications
ANNEXES
Annex A (normative) - Protocol Implementation Conformance
statement (PICS) proforma
Annex B (normative) - Channel design considerations
Annex C (informative) - Jitter considerations
Annex D (informative) - Transmitter example
Annex E (informative) - Safety and environmental
considerations
Annex F (informative) - Low-level finite-state machines
(FSMs)
Annex G (informative) - Differences from 1992 version
Annex H (informative) - Example of a MAC frame parsing
algorithm
Annex I (informative) - Recommended use of priorities
for token ring
Annex J (informative) - Bibliography
Annex P (normative) - Bit error rate (BER) criteria for
lobe media testing
Scope For the purpose of compatible interconnection of data processing equipment via a local area network(LAN) using the token ring access method, this part of ISO/IEC 8802 a) Provides a general description of the token ring local area network (LAN) architecture (clause 2); b) Defines the frame format, including the delimiters, address fields, information field, and frame-check sequence (FCS). Defines the Medium Access Control (MAC) frames, timers, and error counters (clause 3); c) Defines the MAC protocols including finite state machines and state tables (clause 4); d) Defines the system level Physical layer (PHY) signaling specifications that are specific to a ring station (clause 5); e) Defines the managed objects necessary to manage the service and protocol elements that are involved in the management of a token ring station (clause 6); f) Defines the PHY station attachment specification for 4 and 16 Mbit/s operation. This includes the transmitter, receiver, medium interface connector, and transmission channel for both shieldedtwisted pair (STP) and unshielded twisted pair (UTP) media (clause 7); g) Defines the concentrator, incorporating multiple trunk coupling units (TCUs), for the attachment of a group of stations to the ring (clause 8); h) Includes the protocol implementation conformance statement (PICS) proforma in compliance with the relevant requirements, and in accordance with the relevant guidance, given in ISO/IEC 9646-2 : 1994. (annex A); i) Includes channel design examples and formulas for calculating cabling and concentrator system configurations (annex B); j) Describes jitter components and provides an example of jitter buildup using a phase lock loop recovery circuit (annex C); k) Provides informative transmitter filter design example (annex D); l) Provides recommended guidelines for safety and operating environments (annex E); m) Illustrates the MAC finite state machines in a notation similar to that used in lSO/IEC 8802-5 : 1992 (annex F); n) Describes major improvements made after the first edition of the standard (annex G); o) Provides a sample algorithm for the parsing of MAC frames (annex H); p) Provides recommendations for the use of token ring access priorities to support multimedia traffic (annex I); q) Provides bit error rate (BER) criteria for lobe media testing (annex P).
DevelopmentNote |
Amendment 1 is available separately - See record CSA ISO/IEC 8802-5A. (06/2007)
|
DocumentType |
Standard
|
ISBN |
0-7361-0235-0
|
Pages |
260
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Scope For the purpose of compatible interconnection of data processing equipment via a local area network(LAN) using the token ring access method, this part of ISO/IEC 8802 a) Provides a general description of the token ring local area network (LAN) architecture (clause 2); b) Defines the frame format, including the delimiters, address fields, information field, and frame-check sequence (FCS). Defines the Medium Access Control (MAC) frames, timers, and error counters (clause 3); c) Defines the MAC protocols including finite state machines and state tables (clause 4); d) Defines the system level Physical layer (PHY) signaling specifications that are specific to a ring station (clause 5); e) Defines the managed objects necessary to manage the service and protocol elements that are involved in the management of a token ring station (clause 6); f) Defines the PHY station attachment specification for 4 and 16 Mbit/s operation. This includes the transmitter, receiver, medium interface connector, and transmission channel for both shieldedtwisted pair (STP) and unshielded twisted pair (UTP) media (clause 7); g) Defines the concentrator, incorporating multiple trunk coupling units (TCUs), for the attachment of a group of stations to the ring (clause 8); h) Includes the protocol implementation conformance statement (PICS) proforma in compliance with the relevant requirements, and in accordance with the relevant guidance, given in ISO/IEC 9646-2 : 1994. (annex A); i) Includes channel design examples and formulas for calculating cabling and concentrator system configurations (annex B); j) Describes jitter components and provides an example of jitter buildup using a phase lock loop recovery circuit (annex C); k) Provides informative transmitter filter design example (annex D); l) Provides recommended guidelines for safety and operating environments (annex E); m) Illustrates the MAC finite state machines in a notation similar to that used in lSO/IEC 8802-5 : 1992 (annex F); n) Describes major improvements made after the first edition of the standard (annex G); o) Provides a sample algorithm for the parsing of MAC frames (annex H); p) Provides recommendations for the use of token ring access priorities to support multimedia traffic (annex I); q) Provides bit error rate (BER) criteria for lobe media testing (annex P).
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
ISO/IEC 10165-5:1994 | Information technology Open Systems Interconnection Structure of management information: Generic management information |
ISO/IEC 15802-2:1995 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Common specifications — Part 2: LAN/MAN management |
IEC 60950:1999 | Safety of information technology equipment |
IEEE 802-2014 | IEEE Standard for Local and Metropolitan Area Networks: Overview and Architecture |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60793-2:2015 | Optical fibres - Part 2: Product specifications - General |
ISO/IEC 10165-2:1992 | Information technology Open Systems Interconnection Structure of management information: Definition of management information |
ISO/IEC TR 11802-2:2005 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Technical reports and guidelines Part 2: Standard Group MAC Addresses |
ASTM D 4566 : 2014 : REDLINE | Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable |
ISO/IEC 9595:1998 | Information technology Open Systems Interconnection Common management information service |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 10040:1998 | Information technology Open Systems Interconnection Systems management overview |
ISO/IEC 9646-2:1994 | Information technology Open Systems Interconnection Conformance testing methodology and framework Part 2: Abstract Test Suite specification |
ISO/IEC 8824:1990 | Information technology — Open Systems Interconnection — Specification of Abstract Syntax Notation One (ASN.1) |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
ISO/IEC 10742:1994 | Information technology Telecommunications and information exchange between systems Elements of management information related to OSI Data Link Layer standards |
ISO/IEC TR 11802-4:1994 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Technical reports and guidelines — Part 4: Token ring access method and physical layer specifications — Fibre optic station attachment |
ISO/IEC 15802-1:1995 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Common specifications Part 1: Medium Access Control (MAC) service definition |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
ISO/IEC 9646-1:1994 | Information technology Open Systems Interconnection Conformance testing methodology and framework Part 1: General concepts |
ISO/IEC 9314-3:1990 | Information processing systems Fibre distributed Data Interface (FDDI) Part 3: Physical Layer Medium Dependent (PMD) |
IEC 60060-4:1977 | High-voltage test techniques - Part 4: Application guide for measuring devices |
ISO/IEC 9596-1:1998 | Information technology Open Systems Interconnection Common management information protocol Part 1: Specification |
ISO/IEC 7498-4:1989 | Information processing systems — Open Systems Interconnection — Basic Reference Model — Part 4: Management framework |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
ISO/IEC 8802-2:1998 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 2: Logical link control |
ISO/IEC 10165-4:1992 | Information technology Open Systems Interconnection Structure of management information Part 4: Guidelines for the definition of managed objects |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.