CAN/CSA-C50-14 (R2018)
Current
The latest, up-to-date edition.
Mineral insulating oil, electrical, for transformers and switches
Hardcopy , PDF
English, French
01-01-2014
Preface
1 Scope
2 Reference publications
3 Definitions
4 General requirements
5 Sampling
6 Properties
7 Delivery
Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised by not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
DevelopmentNote |
French Edition issued on 01-08-2014. (08/2014)
|
DocumentType |
Standard
|
ISBN |
978-1-77139-567-0
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised by not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
CSA C60044-5:2007 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
CSA C60044-5 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS |
CSA C2 : 0 | SINGLE-PHASE AND THREE-PHASE DISTRIBUTION TRANSFORMERS, TYPES ONAN AND LNAN |
CSA C227.3 : 2006 | LOW-PROFILE, SINGLE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS |
CSA C22.3 No. 61936-1 : 2008 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CSA C22.3 No. 61936-1 : 2008 : R2015 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CSA C227.4 : 2006 | THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS |
CSA C2.2:2006 : R2011 | POLE-MOUNTED, SINGLE-PHASE DISTRIBUTION TRANSFORMERS FOR ELECTRIC UTILITIES |
CSA C2.1 : 2006 | SINGLE-PHASE AND THREE-PHASE LIQUID-FILLED DISTRIBUTION TRANSFORMERS |
CSA C60044-2 : 2007 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
CSA C60044-2 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
CSA C61869-1 : 2014 | INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 107.1 : 2016 | POWER CONVERSION EQUIPMENT |
CAN/CSA-C227.3-06 (R2017) | Low-profile, single-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors |
CSA C227.4 : 2006 : R2017 | THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS |
CSA C227.5 : 2008 : R2013 | THREE-PHASE LIVE-FRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS |
CSA C227.3 : 2006 : R2011 | LOW-PROFILE, SINGLE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS |
CSA C2.1 : 2006 : R2011 | SINGLE-PHASE AND THREE-PHASE LIQUID-FILLED DISTRIBUTION TRANSFORMERS |
CSA C2.2 : 2006 | POLE-MOUNTED, SINGLE-PHASE DISTRIBUTION TRANSFORMERS FOR ELECTRIC UTILITIES |
CSA C227.5:2008 | THREE-PHASE LIVE-FRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS |
CSA C227.4 : 2006 : R2011 | THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS |
C88-16 | Power transformers and reactors |
IEC 61125:1992 | Unused hydrocarbon based insulating liquids - Test methods for evaluating the oxidation stability |
ASTM D 1816 : 2012 : REDLINE | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes |
ASTM D 924 : 2015 : REDLINE | Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids |
IEC 62535:2008 | Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil |
IEC 60475:2011 | Method of sampling insulating liquids |
IEC 61868:1998 | Mineral insulating oils - Determination of kinematic viscosity at very low temperatures |
ASTM D 1275 : 2015 | Standard Test Method for Corrosive Sulfur in Electrical Insulating Liquids |
ASTM D 1533 : 2012 : REDLINE | Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration |
ASTM D 2440 : 2013 : REDLINE | Standard Test Method for Oxidation Stability of Mineral Insulating Oil |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
ASTM D 341 : 2017 : REDLINE | Standard Practice for Viscosity-Temperature Charts for Liquid Petroleum Products |
IEC 62697-1:2012 | Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids - Part 1: Test method for quantitative determination of dibenzyldisulfide (DBDS) |
IEC 60666:2010 | Detection and determination of specified additives in mineral insulating oils |
ASTM D 5837 : 2015 : REDLINE | Standard Test Method for Furanic Compounds in Electrical Insulating Liquids by High-Performance Liquid Chromatography (HPLC) |
ASTM D 923 : 2015 : REDLINE | Standard Practices for Sampling Electrical Insulating Liquids |
ASTM D 2112 : 2015 : REDLINE | Standard Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel |
ASTM D 877/D877M : 2013 : REDLINE | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes |
ASTM D 3300 : 2012 : REDLINE | Standard Test Method for Dielectric Breakdown Voltage of Insulating Oils of Petroleum Origin Under Impulse Conditions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.