C22.2 NO. 1993-17
Current
The latest, up-to-date edition.
Self-ballasted lamps and lamp adapters (Trinational standard with NMX-J-578/1-ANCE and UL 1993)
Hardcopy , PDF
English
01-01-2017
Preface
1 Scope
2 Reference Publications
3 Definitions
4 General Requirements
5 Mechanical Construction
6 Electrical Construction
7 Environmental Locations
8 Tests
9 Test Apparatus
10 Device Markings
SUPPLEMENT SA - SUPPLEMENTAL REQUIREMENTS FOR LIGHT-EMITTING
DIODES (LED)
SUPPLEMENT SB - ADDITIONAL REQUIREMENTS FOR SOLID-STATE LAMPS
CONTAINING SILICONE FLUID
SUPPLEMENT SC - ADDITIONAL REQUIREMENTS FOR LED LAMPS AND
FLUORESCENT LAMP ADAPTERS INTENDED AS DIRECT
REPLACEMENTS FOR FLUORESCENT LAMPS
ANNEX A (normative) - Standards for Components
ANNEX B (CAN) (normative) - Markings - French Translations
ANNEX C (MEX) (normative) - Markings - Spanish Translations
ANNEX D (normative) - Manufacturing and Production Tests
ANNEX E (CAN) (normative) - Printed Circuit Boards
ANNEX F (informative) - Pictograms
ANNEX G (informative) - Metric Conversion Information
Pertains to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders.
DevelopmentNote |
Also numbered as NMX-J-578/1-ANCE & UL 1993. (09/2009) This standard was just updated in our system however it was originally released on 08-2018
|
DocumentType |
Standard
|
ISBN |
978-1-77139-711-7
|
Pages |
218
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the harmonized ANCE, CSA Group, and UL standard for Self-Ballasted Lamps and Lamp Adapters. It is the third edition of NMX-J-578/1-ANCE, the third edition of CSA C22.2 No. 1993, and the fifth edition of UL 1993. This edition of CSA C22.2 No. 1993 supersedes the previous edition published in 2012. This harmonized standard has been jointly revised on March 26, 2021. For this purpose, CSA Group and UL are issuing revision pages dated March 26, 2021, and ANCE is issuing a new edition dated March 26, 2021. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Self-Ballasted Lamps, of the Council of the Harmonization of Electrotechnical Standards for the Nations of the Americas (CANENA), are gratefully acknowledged. In Canada, for general information on the Standards of the Canadian Electrical Code, Part II, see the preface to CAN/CSA-C22.2 No. 0. Scope 1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code Part I, CSA C22.1, in non-hazardous locations, and the Instalaciones Elctricas (utilizacin), NOM-001-SEDE. 1.2 These devices incorporate resistance, reactance, or electronic (solid-state) type ballasts or power supplies. These devices employ various lamp technologies including, but not limited to, incandescent, fluorescent, high-intensity discharge lamps, light-emitting diodes. 1.3 These requirements also include Supplemental Requirements for Light-Emitting Diodes (LED), Supplement SA, for: a) Self-contained LED lamps, rated 120 to 347 V AC nominal for connection to screw-, pinbase, and recessed single contact (RSC or R7) lampholders b) Lamps for replacement of an ANSI standardized fluorescent lamp, and consisting of lightemitting-diode (LED) lamp technologies, with control circuitry, and a driver or power supply. The LED driver and control circuitry will be either integral with the lamp or remote from the lampand c) Component LED lamps, with or without control circuitry, an ANSI base other than bases mentioned in (a), for connection to LED driver having a low voltage output, such as replacement for tungsten-halogen, MR11 and MR16 shaped lamps. 1.4 This standard does not apply to medium-to-medium base (E26) fittings that incorporate controls such as photocells, motion detectors, radio controls, or dimmers covered by other standards. 1.5 These devices are not intended for use with emergency exit fixtures or emergency exit lights.
CSA C861:2010 | PERFORMANCE OF SELF-BALLASTED COMPACT FLUORESCENT LAMPS AND BALLASTED ADAPTERS |
CSA C22.2 No. 37 : 2017 | DECORATIVE LIGHTING PRODUCTS |
CSA C22.2 No. 250.1 : 2016 | RETROFIT KITS FOR LUMINAIRE CONVERSION |
CSA C22.2 No. 62560 : 2016 | SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES BY VOLTAGE > 50 V - SAFETY SPECIFICATIONS |
CSA C22.2 No. 207 : 2015 | PORTABLE AND STATIONARY ELECTRIC SIGNS AND DISPLAYS |
CSA C861 : 2010 : INC : UPD 1 : 2012 | PERFORMANCE OF SELF-BALLASTED COMPACT FLUORESCENT LAMPS AND BALLASTED ADAPTERS |
CSA C22.2 No. 61347-2-13 : 2015(R2020) | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
CSA C22.2 No. 250.4 : 2014 | PORTABLE LUMINAIRES |
CSA C22.2 No. 250.13 : 2017 | LIGHT EMITTING DIODE (LED) EQUIPMENT FOR LIGHTING APPLICATIONS |
CSA C22.2 No. 62031 : 2013(R2018) | LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS |
CSA C22.2 No. 166 : 2015 | STAGE AND STUDIO LUMINAIRES |
CSA C861 : 2010 : R2015 | PERFORMANCE OF SELF-BALLASTED COMPACT FLUORESCENT LAMPS AND BALLASTED ADAPTERS |
CAN/CSA-C875-13 (R2018) | Performance of general service directional lamps |
CSA C22.2 No. 61347-2-13 : 2015 | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
ANSI C81.62 : 2017 | ELECTRIC LAMPHOLDERS |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
CSA C22.2 No. 223 : 2015 | POWER SUPPLIES WITH EXTRA-LOW-VOLTAGE CLASS 2 OUTPUTS |
UL 5085-3:1ED 2006-04-17 | Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
CSA C22.2 No. 60065 : 2016 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS |
CSA C22.2 No. 49 : 2014 | FLEXIBLE CORDS AND CABLES |
UL 506:14ED 2017-06-02 | Specialty Transformers |
ANSI C78.81:2016 | American National Standard for Electric Lamps—Double-Capped Fluorescent Lamps—Dimensional and Electrical Characteristics |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
UL 935:10ED 2001-05-21 | Fluorescent-Lamp Ballasts |
UL 83:16ED 2017-07-28 | Standard for Thermoplastic-Insulated Wires and Cables |
ANSI C81.61 : 2017 | ELECTRIC LAMP BASES - SPECIFICATIONS FOR BASES (CAPS) FOR ELECTRIC LAMPS |
NFPA 704 : 2017 | STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS FOR EMERGENCY RESPONSE |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
C22.2 NO. 43-17 | Lampholders (Binational standard with UL 496) |
CSA C22.2 No. 250.13 : 2017 | LIGHT EMITTING DIODE (LED) EQUIPMENT FOR LIGHTING APPLICATIONS |
IEC 60227-1:2007 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
IEC 61347-2-4:2000 | Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting |
ASTM D 1525 : 2017 | Standard Test Method for Vicat Softening Temperature of Plastics |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
ISA MC96.1 : 1982 | TEMPERATURE MEASUREMENT THERMOCOUPLES |
UL 101:6ED 2017-07-31 | Leakage Current for Utilization Equipment |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
ANSI C82.3-2016 | American National Standard for Reference Ballasts for Fluorescent Lamps |
CSA C22.2 No. 0.15 : 2015 | ADHESIVE LABELS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
ASTM D 93 : 2016-07 | TEST METHODS FOR FLASH POINT BY PENSKY-MARTENS CLOSED CUP TESTER |
ANSI C78.375 : A2014 | ELECTRIC LAMPS - FLUORESCENT LAMPS - GUIDE FOR ELECTRICAL MEASURES |
CSA C22.2 No. 210 : 2015 | APPLIANCE WIRING MATERIAL PRODUCTS |
CSA C22.2 No. 127 : 2015 | EQUIPMENT AND LEAD WIRES |
UL 746A:6ED 2012-09-06 | Polymeric Materials - Short Term Property Evaluations |
UL 60730-1:5ED 2016-08-03 | Automatic Electrical Controls - Part 1: General Requirements |
CSA C22.2 No. 74 : 2016 | EQUIPMENT FOR USE WITH ELECTRIC DISCHARGE LAMPS |
ANSI C78.24:2001 | American National Standard for Electric Lamps—Two-inch (51 mm) Integral-Reflector Lamps with Front Covers and GU5.3 or GX5.3 Bases |
UL 1577:5ED 2014-04-25 | Optical Isolators |
CSA C22.2 No. 256 : 2014 | DIRECT PLUG-IN NIGHTLIGHTS |
ASTM D 1000 : 2017 : REDLINE | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
UL 496:14ED 2017-09-05 | Lampholders |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
IEC 61184:2017 | Bayonet lampholders |
ANSI C78.901:2016 | American National Standard for Electric Lamps—Single-Based Fluorescent Lamps—Dimensional and Electrical Characteristics |
ANSI C81.63 : 2007(R2014) | GAUGES FOR ELECTRIC LAMP BASES AND LAMPHOLDERS |
UL 2097:4ED 2006-12-28 | Reference Standard for Double Insulation Systems for Use in Electronic Equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.