BS PAS 121(2007) : 2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING
Hardcopy , PDF
01-07-2013
English
01-01-2007
Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Product requirements
5 Performance requirements and classifications
6 Installation information
7 Maintenance information
8 Marking and labelling
Annexes
Annex A (informative) - Building management
Annex B (normative) - General testing requirements
Annex C (normative) - Test method for reliability and
response time of the product and the durability
of materials
Annex D (normative) - Test method for the determination
of the fire resistance performance of fire curtain
barrier assemblies
Annex E (informative) - An engineered approach to using
insulating zones
Annex F (informative) - Thermal limits - Human factors
Bibliography
Provides requirements for design, specification, testing, installation, commissioning and maintenance of active fire curtain barrier assemblies.
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
12/30263295 DC : 0 | BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION |
BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
BS 9991:2011 | Fire safety in the design, management and use of residential buildings. Code of practice |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
BS EN 13501-2 : 2007 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES |
BS EN 1634-1 : 2014 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS |
BS EN 1364-2:1999 | Fire resistance tests for non-loadbearing elements Ceilings |
BS EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
BS EN ISO 13943:2017 | Fire safety. Vocabulary |
BS EN 1634-3:2004 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies |
BS 5588-12:2004 | Fire precautions in the design, construction and use of buildings Managing fire safety |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN 1364-1:2015 | Fire resistance tests for non-loadbearing elements Walls |
BS 8434-2(2003) : 2003 | METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY |
BS EN 1363-2:1999 | Fire resistance tests Alternative and additional procedures |
BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
BS EN 949:1999 | Windows and curtain walling, doors, blinds and shutters. Determination of the resistance to soft and heavy body impact for doors |
BS EN 1363-1:2012 | Fire resistance tests General requirements |
BS 8434-1:2003 | Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with addition of water spray |
BS EN 12101-1 : 2006 | SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS |
BS 7346-6:2005 | Components for smoke and heat control systems Specifications for cable systems |
EN 15269-1:2010 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements |
PD 7974-6:2004 | The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6) |
ISO/IEC Guide 2:2004 | Standardization and related activities — General vocabulary |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS 476-31.1:1983 | Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions |
BS EN 12101-10:2005 | Smoke and heat control systems Power supplies |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.