BS ISO 26802:2010
Current
The latest, up-to-date edition.
Nuclear facilities. Criteria for the design and the operation of containment and ventilation systems for nuclear reactors
Hardcopy , PDF
English
31-08-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Functions ensured by the ventilation system
5 Architecture and description of the different ventilation
systems
6 Safety aspects for ventilation systems
7 Requirements for the design of ventilation systems
8 Management of specific risks
9 Dispositions concerning the management and the operation
of the ventilation systems
10 Control and instrumentation
Annex A (informative) - Typical radioactive products in nuclear
reactors
Annex B (informative) - Examples of general confinement concepts
for nuclear power reactors
Annex C (informative) - Examples of safety classification for
nuclear power reactors
Annex D (informative) - Examples of classification of working
areas according to radiological contamination hazard
Annex E (informative) - Example of classification of types of
ventilation, according to radiological contamination
hazard - Recommended ventilation configurations
Annex F (informative) - Existing requirements for aerosol filters
Annex G (informative) - Examples of loads to consider during the
design of NPP ventilation systems
Annex H (informative) - Typical values of leaktightness for
containment and ventilation systems and periodicities
of associated controls
Annex I (informative) - Primary containment envelope status
Bibliography
Defines the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors.
Committee |
NCE/2
|
DevelopmentNote |
Supersedes 08/30151428 DC. (09/2010) Reviewed and confirmed by BSI, May 2016. (05/2016)
|
DocumentType |
Standard
|
Pages |
96
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors, taking into account the following.
For nuclear power plants, this International Standard addresses only reactors that have a secondary confinement system based on International Atomic Energy Agency (IAEA) recommendations (see Reference [10]).
For research reactors, this International Standard applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or high-temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.
For research reactors in which the increase of pressure or temperature during accidental situations will not damage the ventilation systems, the requirements applicable for the design and the use of ventilation systems are given in ISO17873. However, the requirements of this International Standard can also be applied.
Standards | Relationship |
ISO 26802:2010 | Identical |
ISO 11933-4:2001 | Components for containment enclosures — Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices |
ASHRAE 52.1 : 0 | GRAVIMETRIC AND DUST SPOT PROCEDURES FOR TESTING AIR CLEANING DEVICES USED IN GENERAL VENTILATION FOR REMOVING PARTICULATE MATTER |
ISO 10648-1:1997 | Containment enclosures — Part 1: Design principles |
ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
NFX 44 060 : 1993 | AIR CLEANING EQUIPMENT - OIL MUST GAS PURIFIERS WITH INTEGRAL FAN FOR SCREW-CUTTING INDUSTRY - TEST METHOD |
ASME AG 1 : 2012 | CODE ON NUCLEAR AIR AND GAS TREATMENT |
EN 779:2012 | Particulate air filters for general ventilation - Determination of the filtration performance |
ISO 17873:2004 | Nuclear facilities — Criteria for the design and operation of ventilation systems for nuclear installations other than nuclear reactors |
EN 1822-2:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics |
DIN 24185-2:1980-10 | METHOD OF TESTING AIR FILTERS USED IN GENERAL VENTILATION - FILTER CLASSIFICATION, MARKING, TEST |
ISO 2889:2010 | Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities |
ISO 8421-1:1987 | Fire protection — Vocabulary — Part 1: General terms and phenomena of fire |
DIN 24185-1:1980-10 | METHOD OF TESTING AIR FILTERS USED IN GENERAL VENTILATION - TERMS, UNITS, METHODS |
ISO 10648-2:1994 | Containment enclosures — Part 2: Classification according to leak tightness and associated checking methods |
EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
ISO 15080:2001 | Nuclear facilities — Ventilation penetrations for shielded enclosures |