BS ISO 24237:2005
Current
The latest, up-to-date edition.
Surface chemical analysis. X-ray photoelectron spectroscopy. Repeatability and constancy of intensity scale
Hardcopy , PDF
English
11-09-2005
Foreword
Introduction
1 Scope
2 Symbols and abbreviations
3 Outline of method
4 Method for evaluating the repeatability and constancy of
the intensity scale
4.1 Obtaining the reference sample
4.2 Mounting the sample
4.3 Cleaning the sample
4.4 Choosing the spectrometer settings for which intensity
stability is to be determined
4.5 Operating the instrument
4.6 Options for initial or subsequent evaluation measurements
4.7 Measurements for the intensity and repeatability
4.8 Calculating the peak area intensities, intensity ratios
and uncertainties
4.9 Procedure for the regular evaluation of the constancy
of the intensity scale
4.10 Next evaluation
Annex A (informative) Example of calculations and measurements
of the intensity repeatability for a commercial X-ray
photoelectron spectrometer using unmonochromated
Mg K[Alpha] X-rays
Bibliography
Specifies a method for evaluating the repeatability and constancy of the intensity scale of X-ray photoelectron spectrometers, for general analytical purposes, using unmonochromated Al or Mg X-rays or monochromated Al X-rays.
Committee |
CII/60
|
DevelopmentNote |
Supersedes 04/30109361 DC. (09/2005) Reviewed and confirmed by BSI, March 2016. (03/2016)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard specifies a method for evaluating the repeatability and constancy of the intensity scale of X-ray photoelectron spectrometers, for general analytical purposes, using unmonochromated Al or Mg X-rays or monochromated Al X-rays. It is only applicable to instruments that incorporate an ion gun for sputter cleaning. It is not intended to be a calibration of the intensity/energy response function. That calibration may be made by the instrument manufacturer or other organization. The present procedure provides data to evaluate and confirm the accuracy with which the intensity/energy response function remains constant with instrument usage. Guidance is given on some of the instrument settings that may affect this constancy.
Standards | Relationship |
ISO 24237:2005 | Identical |
ISO 18118:2015 | Surface chemical analysis — Auger electron spectroscopy and X-ray photoelectron spectroscopy — Guide to the use of experimentally determined relative sensitivity factors for the quantitative analysis of homogeneous materials |
ISO 7873:1993 | Control charts for arithmetic average with warning limits |
ISO 15472:2010 | Surface chemical analysis X-ray photoelectron spectrometers Calibration of energy scales |
ISO 7870:1993 | Control charts General guide and introduction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.