• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN ISO 25539-3:2024

Current

Current

The latest, up-to-date edition.

Cardiovascular implants. Endovascular devices Vena cava filters

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

28-10-2024

£314.00
Excluding VAT

Committee
CH/150/2
DocumentType
Standard
Pages
110
PublisherName
British Standards Institution
Status
Current
Supersedes

This document specifies the requirements for the evaluation of vena cava filter systems (filters and delivery systems) and the requirements with respect to nomenclature, design attributes and information supplied by the manufacturer. Guidance for the development of in vitro test methods is included in AnnexD. This document is intended to be used in conjunction with ISO 14630, which specifies general requirements for the performance of non-active surgical implants. NOTE1 Due to the variations in the design of implants covered by this document, and in some cases due to the emergence of novel types of such implants, acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, a revision of this document will be necessary. This document is applicable to vena cava filters intended to prevent symptomatic pulmonary embolism by capturing blood clots in the inferior vena cava (IVC). While this document can be useful with respect to filters implanted in other venous locations (e.g. superior vena cava, iliac veins), it does not specifically address the use of filters in other implantation sites. This document is also applicable to permanent filters together with their associated delivery systems, optional filters that can be retrieved and their associated retrieval systems, and convertible filters and their associated conversion systems. While this document can be useful with respect to the evaluation of repositioning filters after chronic implantation, it does not specifically address filter repositioning. This document is not applicable to — temporary filters (e.g. tethered) that need to be removed after a defined period of time, — issues associated with viable tissues and non-viable biological materials, and — procedures and devices (e.g. venous entry needle) used prior to the vena cava filter procedure. Although absorbable filters and filters with absorbable coatings are within the scope of this document, this document is not comprehensive with respect to the absorbable properties of these devices. NOTE2 Absorbable implants are covered in ISO/TS 17137. Although coated filters and coated filter systems are within the scope of this document, this document is not comprehensive with respect to coatings. NOTE3 Vascular device-drug combination products are covered in ISO 12417-1 and some coating properties are covered in ISO 25539-4.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.