BS EN ISO 16251-1:2014
Current
The latest, up-to-date edition.
Acoustics. Laboratory measurement of the reduction of transmitted impact noise by floor coverings on a small floor mock-up Heavyweight compact floor
Hardcopy , PDF
English
31-08-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Equipment
6 Test procedure
7 Uncertainty
8 Expression of results
9 Test report
Annex A (normative) - Test setup
Annex B (informative) - Design of presentation of results
Bibliography
Defines a laboratory measurement method to determine the improvement of impact sound insulation by a floor covering when laid on a standard concrete floor mock-up and excited by a standard tapping machine.
Committee |
EH/1/6
|
DevelopmentNote |
Supersedes 12/30239340 DC. (08/2014)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO16251 specifies a laboratory measurement method to determine the improvement of impact sound insulation by a floor covering when laid on a standard concrete floor mock-up and excited by a standard tapping machine. The method is restricted to soft, flexible floor coverings, which transmit impact sound mainly “locally” into the floor, i.e. through the area close to the points of excitation, so that the size of the flooring specimen does not have an influence on the results. Examples of such floor coverings are carpets, PVC, and linoleum. These floor coverings correspond to ISO10140-1:2010[5], AnnexH, category I.
The results only provide information about the noise radiated. A subjective classification of the quality of the floor coverings is not intended.
The method is kept as close as possible to the ISO10140[4] series and yields the same results within the range of uncertainty and within the range of application. In the case of difference with ISO10140, the result of the ISO10140 measurement shall be used.
This part of ISO16251 provides the measurement method. Product test codes can contain further requirements concerning the specimens, such as temperature range, the number of test specimens or special mounting conditions.
NOTE If non-soft, non-flexible floorings are tested, e.g. those with a laminated structure, increased deviations from the results of the ISO10140[4] series method may occur due to the dependency on the specimen size.
Standards | Relationship |
EN ISO 16251-1:2014 | Identical |
ISO 16251-1:2014 | Identical |
ISO 717-2:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 2: Impact sound insulation |
ISO 266:1997 | Acoustics — Preferred frequencies |
ISO 10140-1:2016 | Acoustics Laboratory measurement of sound insulation of building elements Part 1: Application rules for specific products |
ISO 5348:1998 | Mechanical vibration and shock Mechanical mounting of accelerometers |
ISO 10140-5:2010 | Acoustics Laboratory measurement of sound insulation of building elements Part 5: Requirements for test facilities and equipment |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
ISO 12999-1:2014 | Acoustics Determination and application of measurement uncertainties in building acoustics Part 1: Sound insulation |