BS EN ISO 11855-4:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Building environment design. Design, dimensioning, installation and control of embedded radiant heating and cooling systems Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS)
Hardcopy , PDF
01-10-2021
English
31-08-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 The concept of Thermally Active
Surfaces (TAS)
6 Calculation methods
7 Input for computer simulations of
energy performance
Annex A (informative) - Simplified diagrams
Annex B (normative) - Calculation method
Annex C (informative) - Tutorial guide for assessing
the model
Annex D (informative) - Computer program
Bibliography
Permits the calculation of peak cooling capacity of Thermo Active Building Systems (TABS), based on heat gains, such as solar gains, internal heat gains, and ventilation, and the calculation of the cooling power demand on the water side, to be used to size the cooling system, as regards the chiller size, fluid flow rate, etc.
Committee |
RHE/24
|
DevelopmentNote |
Supersedes BS EN 15377-3 & 10/30197172 DC. (08/2015)
|
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN ISO 11855-4:2015 | Identical |
ISO 11855-4:2012 | Identical |
EN 15251:2007 | Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics |
EN 1264-5:2008 | Water based surface embedded heating and cooling systems - Part 5: Heating and cooling surfaces embedded in floors, ceilings and walls - Determination of the thermal output |
EN 15377-3:2007 | Heating systems in buildings - Design of embedded water based surface heating and cooling systems - Part 3: Optimizing for use of renewable energy sources |
EN 15265:2007 | Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures |
ISO 11855-2:2012 | Building environment design Design, dimensioning, installation and control of embedded radiant heating and cooling systems Part 2: Determination of the design heating and cooling capacity |
EN 15377-1:2008 | Heating systems in buildings - Design of embedded water based surface heating and cooling systems - Part 1: Determination of the design heating and cooling capacity |
ISO 11855-1:2012 | Building environment design Design, dimensioning, installation and control of embedded radiant heating and cooling systems Part 1: Definition, symbols, and comfort criteria |
ISO 7730:2005 | Ergonomics of the thermal environment — Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria |
EN 1264-2:2008+A1:2012 | Water based surface embedded heating and cooling systems - Part 2: Floor heating: Prove methods for the determination of the thermal output using calculation and test methods |
EN 15255:2007 | Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.