BS EN 88:1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Pressure governors for gas appliances for inlet pressures up to 200 mbar
Hardcopy , PDF
31-12-2007
English
29-11-1991
Cooperating organizations
National foreword
Foreword
1. General
1.1 Object and field of application
1.2 References
1.3 Definitions
1.4 Classification
1.5 Measuring ratio
2. Construction requirements
2.1 General
2.2 Materials
2.3 Connections
2.4 Seals for glands for moving parts
2.5 Pressure test nipples
3. Performance requirements
3.1 General
3.2 Putting the governor out of action
3.3 External leak-tightness
3.4 Torsion and bending
3.5 Durability
3.6 Governor performance
3.7 text deleted
3.8 Durability of performance
3.9 Lock-up pressure
4. Test methods
4.1 General
4.2 Putting the governor out of action
4.3 External leak-tightness
4.4 Torsion and bending
4.5 Durability
4.6 Governor performance
4.7 text deleted
4.8 Durability of performance
4.9 Lock-up pressure
5. Marking, installation and operating instructions
5.1 Marking
5.2 Installation, operating and servicing instructions
5.3 Warning notice
Annexes
A. Characteristics of combustible gases
B. Typical governors and governor parts
C. Use of ISO 7-1: 1982 and ISO 228-1: 1982 threads
for gas connections
D. Leak-tightness test - volumetric method
E. Leak-tightness test - pressure loss method
F. Conversion of pressure loss into leakage rate
G. Summary of requirements and test conditions
Tables
1. Connection sizes
2. Maximum external leakage rates
3. Torque and bending moment
4. Gas pressure at inlet to the governor
5. Outlet pressure variation from the outlet setting
pressure
6. Sequence of testing
7. Tightening torque for flange bolts to ISO 7005-2:
1988
Figures
1. Arrangement for torsion test
2. Arrangement for bending test
3. Paint scratch test apparatus
4. Governor performance test rig
5. Graph of performance using inlet pressure variation
6. Graph of performance using flow rate variation
7. Types of constant pressure governor (diagrammatic)
8. Apparatus for testing leak-tightness (volumetric
method)
9. Apparatus for testing leak-tightness (pressure loss
method)
Requirements and methods of test for pressure governors for use with gas appliances for nominal size up to and including DN 50. Does not cover governors connected directly to mains pipework or for installation out of doors and exposed to the environment.
Committee |
GSE/22
|
DevelopmentNote |
Supersedes 77/73411 DC and BS 6448-1(1987) (09/2005)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNI EN 88 : 1993 AMD 1 1997 | Identical |
NS EN 88 : 1991 AMD 1 1996 | Identical |
I.S. EN 88:1992 | Identical |
NEN EN 88 : 1992 AMD 1 1996 | Identical |
EN 88:1991/A1:1996 | Identical |
SN EN 88 : 1997 AMD 1 1997 | Identical |
NF EN 88 : 91 AMD 1 96 | Identical |
DIN EN 88:1996-08 | Identical |
BS 7977-2:2003 | Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler |
BS EN 297:1994 | Gas-fired central heating boilers. Type B<sub>11</sub> and B<sub>11BS</sub> boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW |
BS 5991:2006 | Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases) |
BS 6644(2005) : 2005 | SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 5990:2006 | Specification for direct gas-fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases) |
BS 6644:2011 | Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases) |
11/30229801 DC : 0 | BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 7977-1:2002 | Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors |
03/310868 DC : DRAFT JUNE 2003 | BS 6644 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70KW (NET) AND 2MW (GROSS) (2ND AND 3RD FAMILY GASES) |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
ISO 274:1975 | Copper tubes of circular section — Dimensions |
BS 3643-1:1981 | ISO metric screw threads Principles and basic data |
ISO 6708:1995 | Pipework components Definition and selection of DN (nominal size) |
BS 1387:1985 | Specification for screwed and socketed steel tubes and tubulars and for plain end steel tubes suitable for welding or for screwing to BS 21 pipe threads |
ISO 301:2006 | Zinc alloy ingots intended for castings |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.