BS EN 62209-2:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Human exposure to radio frequency fields from hand-held and bodymounted wireless communication devices. Human models, instrumentation, and procedures Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
Hardcopy , PDF
05-07-2022
English
31-08-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Measurement system specifications
6 Protocol for SAR evaluation
7 Uncertainty estimation
8 Measurement report
Annex A (informative) - Phantom rationale
Annex B (normative) - SAR measurement system verification
Annex C (informative) - Fast SAR testing
Annex D (informative) - Standard sources and phantoms
for system validation
Annex E (informative) - Example recipes for phantom
tissue-equivalent liquids
Annex F (normative) - SAR correction for deviations of
complex permittivity from targets
Annex G (informative) - Hands-free kit testing
Annex H (informative) - Skin enhancement factor
Annex I (informative) - Tissue-equivalent liquid dielectric
property measurements and measurement uncertainty
estimation
Annex J (informative) - Testing compliance for the exposure
of the hand
Annex K (informative) - Test reduction
Annex L (normative) - Power scaling procedure
Annex M (informative) - Rationale for probe parameters
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments.
Committee |
GEL/106
|
DocumentType |
Standard
|
Pages |
118
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy |
IEC 62209-2:2010 is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. IEC 62209-2:2010 is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types:
- body-mounted,
- body-supported,
- desktop,
- front-of-face,
- hand-held,
- laptop,
- limb-mounted,
- multi-band,
- push-to-talk,
- clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. IEC 62209-2:2010 gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. The contents of the corrigendum of June 2010 have been included in this copy.
Standards | Relationship |
IEC 62209-2:2010 | Identical |
EN 62133:2003 | Identical |
IEC TR 61857-2:2015 | Identical |
IEC 62209-2:2010/COR1:2010 | Identical |
EN 62209-2:2010 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEEE 1528-2013 REDLINE | IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques |
IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
EN 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.