BS EN 61918:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Industrial communication networks. Installation of communication networks in industrial premises
Hardcopy , PDF
30-11-2018
English
30-09-2014
Committee |
GEL/65/3
|
DevelopmentNote |
2013 version incorporates COR 2014. Supersedes 12/30259812 DC. (09/2014)
|
DocumentType |
Standard
|
Pages |
184
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This International Standard specifies basic requirements for the installation of media for communication networks in industrial premises and within and between the automation islands, of industrial sites. This standard covers balanced and optical fibre cabling. It also covers the cabling infrastructure for wireless media, but not the wireless media itself. Additional media are covered in the IEC 61784-5 series.
This standard is a companion standard to the communication networks of the industrial automation islands and especially to the communication networks specified in the IEC 61158 series and the IEC 61784 series. In addition, this standard covers:
the installation of generic telecommunication cabling for industrial premises as specified in ISO/IEC 24702;
the connection between the generic telecommunications cabling specified in ISO/IEC 24702 and the specific communication cabling of an automation island, where an automation outlet (AO) replaces the telecommunication outlet (TO) of ISO/IEC 24702.
NOTE If the interface used at the AO does not conform to that specified for the TO of ISO/IEC 24702, the cabling no longer conforms to ISO/IEC 24702 although certain features, including performance, of generic cabling may be retained.
This standard provides guidelines that cope with the critical aspects of the industrial automation area (safety, security and environmental aspects such as mechanical, liquid, particulate, climatic, chemicals and electromagnetic interference).
This standard does not recognise implementations of power distribution through Ethernet balanced cabling systems that are not specified in IEEE 802.3 and in IEEE 802.3at.
This standard deals with the roles of planner, installer, verifier, and acceptance test personnel, administration and maintenance personnel and specifies the relevant responsibilities and/or gives guidance.
Standards | Relationship |
EN 61918:2013 | Identical |
EN 61918:2013/AC:2014 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
ISO/IEC 14763-2:2012 | Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
EN 61076-2-101:2012 | Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking |
IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
EN 61754-2:1997 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
IEC 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC) |
IEC 60228:2004 | Conductors of insulated cables |
IEC 61984:2008 | Connectors - Safety requirements and tests |
IEC 60807-3:1990 | Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
IEC 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
EN 61784-3:2016/A1:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017) |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
IEC 60670-1:2015 | Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements |
EN 61076-3-106 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-106: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE |
ISO/IEC 9314-4:1999 | Information technology Fibre Distributed Data Interface (FDDI) Part 4: Single Mode Fibre Physical Layer Medium Dependent (SMF-PMD) |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEEE 802-2014 | IEEE Standard for Local and Metropolitan Area Networks: Overview and Architecture |
IEC 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
EN 61076-3-117:2009 | Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface - Variant 14 related to IEC 61076-3-106 - Push pull coupling |
ISO/IEC 24702:2006 | Information technology Generic cabling Industrial premises |
EN 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
EN 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 ohms (type BNC) |
IEC 61076-3-117:2009 | Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface - Variant 14 related to IEC 61076-3-106 - Push-pull coupling |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 62026-3:2014 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet |
EN 60793-2-10:2017 | Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
IEC 60757:1983 | Code for designation of colours |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61754-2:1996 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
ISO/IEC TR 29106:2007 | Information technology Generic cabling Introduction to the MICE environmental classification |
HD 60364-4-442:2012 | Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage system and due to faults in the low voltage system |
EN 61754-4:2013/AC:2014 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 4: TYPE SC CONNECTOR FAMILY (IEC 61754-4:2013) |
HD 457 : 200S1 | CODE FOR DESIGNATION OF COLOURS |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60950-21:2002 | Information technology equipment - Safety - Part 21: Remote power feeding |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 62026-3:2015 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61076-3-106:2006 | Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 61935-1:2015 | Specification for the testing of balanced and coaxial information technology cabling - Part 1: Installed balanced cabling as specified in ISO/IEC 11801 and related standards |
IEC PAS 61076-2-109:2010 | Connectors for electronic equipment - Product requirements - Part 2-109: Circular connectors - Detail specification for connectors M12 x 1 with screw-locking, for data transmissions with frequencies up to 500 MHz |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
ISO/IEC 9314-3:1990 | Information processing systems Fibre distributed Data Interface (FDDI) Part 3: Physical Layer Medium Dependent (PMD) |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 61754-24:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24: Type SC-RJ connector family |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
EN 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
IEC 61076-2-101:2012 | Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking |
IEC 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
EN 60825-2:2004/A2:2010 | SAFETY OF LASER PRODUCTS - PART 2: SAFETY OF OPTICAL FIBRE COMMUNICATION SYSTEMS (OFCS) |
ISO/IEC 14763-3:2014 | Information technology — Implementation and operation of customer premises cabling — Part 3: Testing of optical fibre cabling |
IEC 61754-4:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 4: Type SC connector family |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
EN 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
EN 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
EN 61754-24:2010 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24: Type SC-RJ connector family |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.