FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test levels
6 Test equipment
7 Test set-up
8 Test procedure
9 Evaluation of test results
10 Test report
Annex A (informative) - Sources of disturbances and
        coupling mechanisms
Annex B (informative) - Selection of test levels
Bibliography

Defines common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports.

Committee
GEL/210
DevelopmentNote
Supersedes 95/200656 DC and 98/262652 DC (Shivesh 08/2004) Supersedes 14/30310431 DC. (04/2016) 1998 + A2 2011 Edition remains active & will be withdrawn on 13/01/2019. (08/2016)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. This standard defines test voltage and current waveform; range of test levels; test equipment; test set-up; test procedures. For some types of ports, for example ports intended to be used with highly balanced lines, additional test provisions may be established by product committee specifications. The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system. The disturbances produced by 400Hz mains systems are not included in the scope of this standard. Actual interference due to these disturbance phenomena is relatively rare, except in industrial plants. Product committees should therefore consider whether there is a justification for applying this standard in their product/product family standards (see also Clause4). This test is not relevant for equipment ports intended to be connected to short cables, having a length less than 20m or less. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC61000‑4‑13 and IEC61000‑4‑19 . The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC61000‑4‑6 .

Standards Relationship
UNE-EN 61000-4-16:2016 Identical
SN EN 61000-4-16:2016 Identical
EN 61000-4-16:2016 Identical
I.S. EN 61000-4-16:2016 Identical
NF EN 61000-4-16 : 2016 Identical
DIN EN 61000-4-16 : 2016 Identical
IEC 61000-4-16:2015 Identical

IEC 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC TR 61000-2-3:1992 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 3: Description of the environment - Radiated and non-network-frequency-related conducted phenomena
IEC TR 61000-2-5:2017 Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 60381-2:1978 Analogue signals for process control systems. Part 2: Direct voltage signals
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 61000-4-19:2014 Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.