FOREWORD
1 General
2 Preferred ratings and characteristics
3 Test plan for safety tests
4 Test and measurement procedures
Annex A (informative) - Calculation of leakage current
Annex B (normative) - Test schedule for safety requirements
only
Annex C (normative) - Circuit for the impulse voltage test
Annex D (normative) - Circuit for the endurance test
Annex E (normative) - Declaration of design
Annex F (informative) - Safety and performance tests
qualification approval - Assessment level DZ
Annex P (informative) - Additional components and material
standards
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources.
Committee |
W/-
|
DevelopmentNote |
Supersedes 12/30268003 DC. (12/2015)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This specification covers passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources.
Both single and multi-channel filters within one enclosure or which are built on a printed circuit board forming a compact entity are included within the scope of this specification.
Filters constructed of capacitive elements where the inductance is inherent in the construction of the filter are within the scope of this specification. Similarly, filters constructed of inductive elements where the capacitance is inherent in the construction of the filter are also within the scope of this specification. It is up to the manufacturer to state whether a given component is to be designed as a capacitor, an inductor or a filter. Filters can include also other components like resistors and/or varistors or similar components
This specification applies to passive filter units for electromagnetic interference suppression for which safety tests are appropriate. This implies that filters specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required.
This specification applies to passive filter units, which will be connected to an a.c. mains or other supply (d.c. or a.c.) with a nominal voltage not exceeding 1000V a.c., with a nominal frequency not exceeding 400Hz, or 1500V d.c.
NOTE For a.c. use, IEC60384-14 applies to capacitors which will be connected to a.c. mains with a nominal frequency not exceeding 100Hz.
This specification covers appliance filters (US) but does not cover facility filters, cord-connected filters or direct plug-in filters. These other filters will be covered by another sectional specification.
Standards | Relationship |
IEC 60939-3:2015/COR2:2018 | Identical |
EN 60939-3:2015/AC:2016-04 | Identical |
EN 60939-3:2015 | Equivalent |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 60939-1:2010 | PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION |
EN ISO 80000-1:2013 | Quantities and units - Part 1: General (ISO 80000-1:2009 + Cor 1:2011) |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60938-1:1999/A1:2007 | FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60939-1:2010 | Passive filter units for electromagnetic interference suppression - Part 1: Generic specification |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
IEC 60938-2:1999+AMD1:2006 CSV | Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification |
IEC 60384-9:2015 | Fixed capacitors for use in electronic equipment - Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2 |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60938-1:1999+AMD1:2006 CSV | Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification |
EN 60938-2:1999/A1:2007 | FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 2: SECTIONAL SPECIFICATION |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
ISO 80000-1:2009 | Quantities and units — Part 1: General |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
CISPR 17:2011 | Methods of measurement of the suppression characteristics of passive EMC filtering devices |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 55017 : 2011 | METHODS OF MEASUREMENT OF THE SUPPRESSION CHARACTERISTICS OF PASSIVE EMC FILTERING DEVICES (CISPR 17:2011) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 62109-1:2010 | Safety of power converters for use in photovoltaic power systems - Part 1: General requirements |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
IEC 61112:2009 | Live working - Electrical insulating blankets |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.