1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Quality requirements and tests
6 Classification of tests
7 Capacitance measurement (routine test)
8 Measurement of the tangent of the loss
angle (tan delta) of the capacitor (routine test)
9 Voltage test between terminals (routine test)
10 AC voltage test between terminals and container
(routine test)
11 Test of internal discharge device (routine test)
12 Sealing test (routine test)
13 Thermal stability test (type test)
14 Measurement of the tangent of the loss angle
(tan delta) of the capacitor at elevated temperature
(type test)
15 AC voltage test between terminals and container
(type test)
16 Lightning impulse test between terminals and
container (type test)
17 Short-circuit discharge test (type test)
18 Insulation levels
19 Overloads - Maximum permissible voltage
20 Overloads - Maximum permissible current
21 Safety requirements for discharge devices
22 Safety requirements for container connections
23 Safety requirements for protection of the environment
24 Other safety requirements
25 Markings of the capacitor unit
26 Markings of the capacitor bank
27 Guide for installation and operation
Annex A (normative) - Precautions to be taken to
avoid pollution of the environment by
polychlorinated biphenyls
Annex B (normative) - Additional definitions, requirements
and tests for power filter capacitors
Annex C (normative) - Test requirements and application
guide for external fuses and units to be externally fused
Annex D (informative) - Formulae for capacitors and installations
Annex E (informative) - Capacitor bank fusing and unit
arrangement
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1000 V and frequencies of 15 Hz to 60 Hz.
Committee |
W/-
|
DevelopmentNote |
Together with BS EN 60831-1, BS EN 60831-2, BS EN 60871-4, BS EN 60931-1, BS EN 60931-2 & BS EN 60931-3, supersedes BS 1650(1971). Supersedes BS 7264-1(1990) & 97/207173 DC. (12/2005) Supersedes 02/207951 DC. (03/2006) Supersedes 12/30263682 DC. (08/2014)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC60871 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1000V and frequencies of 15Hz to 60Hz. This part of IEC60871 also applies to capacitors intended for use in power filter circuits. Additional definitions, requirements and tests for filter capacitors are given in AnnexB. Additional requirements for capacitors protected by internal fuses as well as requirements for the internal fuses are given in IEC60871‑4 . Requirements for capacitors to be protected by external fuses, as well as requirements for the same, are given in AnnexC. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors are excluded from this part of IEC60871 : capacitors for inductive heat-generating plants operating at frequencies between 40Hz and 24000Hz ( IEC60110‑1 ); series capacitors for power systems (see the IEC60143 series); capacitors for motor applications and the like (see the IEC60252 series); coupling capacitors and capacitor dividers ( IEC60358 ); shunt capacitors for a.c. power systems having rated voltage up to and including 1000V (see the IEC60831 and IEC60931 series); small a.c. capacitors to be used for fluorescent and discharge lamps ( IEC61048 and IEC61049 ); capacitors to be used in power electronic circuits ( IEC61071 ); capacitors for microwave ovens ( IEC61270‑1 ); capacitors for suppression of radio interference; capacitors intended for use with a.c. voltage superimposed on d.c. voltage. Accessories such as insulators, switches, instrument transformers, external fuses, etc. are in accordance with the relevant IEC standards. The object of this part of IEC60871 is as follows: to formulate uniform rules regarding the performance and rating of units and banks, and the testing of units; to formulate specific safety rules; to provide a guide for installation and operation.
Standards | Relationship |
UNE-EN 60871-1:2014 | Identical |
IEC 60871-1:2014 | Identical |
NF EN 60871-1 : 2014 | Identical |
EN 60871-1:2014 | Identical |
SN EN 60871-1 : 2014 | Identical |
I.S. EN 60871-1:2014 | Identical |
DIN EN 60871-1 : 2015 | Identical |
NBN EN 60871-1 : 2014 | Identical |
IEC 60038:2009 | IEC standard voltages |
IEC 60871-4:2014 | Shunt capacitors for AC power systems having a rated voltage above 1 000 V - Part 4: Internal fuses |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
IEC 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
IEEE 1036-2010 | IEEE Guide for the Application of Shunt Power Capacitors |
IEC TR 60996:1989 | Method for verifying accuracy of tan delta measurements applicable to capacitors |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
IEC 61270-1:1996 | Capacitors for microwave ovens - Part 1: General |
IEC 60273:1990 | Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V |
IEC 61642:1997 | Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 61071:2017 | Capacitors for power electronics |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60050-436:1990 | International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60871-2:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 2: Endurance testing |
EN 60871-4:2014 | Shunt capacitors for AC power systems having a rated voltage above 1 000 V - Part 4: Internal fuses |
IEC TS 60871-3:2015 | Shunt capacitors for a.c. power systems having a rated voltage above 1000 V - Part 3: Protection of shunt capacitors and shunt capacitor banks |
IEEE 18-2012 | IEEE Standard for Shunt Power Capacitors |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
IEC 60110-1:1998 | Power capacitors for induction heating installations - Part 1: General |