BS EN 60255-22-7:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical relays. Electrical disturbance tests for measuring relays and protection equipment Power frequency immunity tests
Hardcopy , PDF
31-07-2014
English
09-06-2003
1 Scope and object
2 Normative references
3 Definitions
4 Test severity levels
5 Test equipment
5.1 Test generator
5.2 Verification of the test generator
5.3 Coupling networks
6 Test set-up
6.1 Earthing connections
6.2 Auxiliary equipment
7 Test procedure
8 Criteria for acceptance
9 Test report
Annex A (informative) Background information for power
frequency tests
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Figure 1 - Port tested in this standard for measuring relays
and protection equipment
Figure 2 - Example of Class A differential mode tests
Figure 3 - Example of Class B differential mode tests
Figure 4 - Example of common mode tests
Specifies the general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems.
Committee |
PEL/95
|
DevelopmentNote |
Supersedes 99/205306 DC (06/2003)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Specifies general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to short duration, conducted, common and differential mode power frequency disturbances. Is based on IEC 61000-4-16.
Standards | Relationship |
EN 60255-22-7:2003 | Identical |
DIN EN 60255-22-7 : 2004 | Identical |
UNE-EN 60255-22-7:2004 | Identical |
I.S. EN 60255-22-7:2005 | Identical |
IEC 60255-22-7:2003 | Identical |
SN EN 60255-22-7 : 2003 | Identical |
NF EN 60255-22-7 : 2003 | Identical |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
EN 61000-4-16:2016 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.